PH
PH
B-315
・All specifications are subject to change without notice.
PH150S110
ITEMS/UNITS
MODEL PH150S110-5 PH150S110-12 PH150S110-15 PH150S110-24 PH150S110-28
Input
Voltage Range
(*6) V
DC82 - 185
Efficiency (typ)
(*1)
%
82
85
88
Current (typ)
(*1) A
1.66
1.60
1.56
Output
Nominal Voltage
VDC
5
12
15
24
28
Maximum Current
A
30
12.5
10
6.3
5.4
Maximum Power
W
150
151.2
Voltage Setting Accuracy (*1)
%
±
1
Maximum Line Regulation (*2) mV
20
48
60
96
112
Maximum Load Regulation (*3) mV
40
96
120
192
224
Temperature Coefficient
0.02%/
℃
Maximum Ripple & Noise (*9) mVp-p
100
150
240
280
Voltage Adjustable Range (*8)
+10%, -10% (At 110VDC Input)
Function
Over Current Protection (*4)
105% - 150%
Over Voltage Protection (*5)
125% - 145%
Remote Sensing
Possible
Remote ON/OFF Control (*8)
Possible (SHORT: ON OPEN: OFF)
Parallel Operation
―――――
Series Operation
(*8)
Possible
Environment
Operating Temperature (*6)
℃
-20 to +85 (Baseplate) Ambient temperature min=-20
Storage Temperature
℃
-40 to +85
Operating Humidity
%
RH
30 - 95 (No dewdrop)
Storage Humidity
%
RH
10 - 95 (No dewdrop)
Vibration
At no operating, 10-55Hz (sweep for 1min)
Amplitude 0.825mm constant (maximum 49.0m/s²) X, Y, Z 1 h each
Shock
196.1m/s² (In package)
Cooling
(*7)
Conduction cooled
Isolation
Withstand Voltage
Input-Baseplate : 2.5kVAC, Input-Output : 3kVAC(20mA) for 1min
Output-Baseplate : 500VDC for 1min
Isolation Resistance
More than 100M
Ω
at 25
℃
and 70%RH Output-Baseplate...500VDC
Standards
Safety Standards
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1
Mechanical
Weight (typ)
g
150
Size (W x H x D)
mm
72 x 12.7 x 86 (Refer to outline drawing)
(*1) At 110VDC and maximum output current.
(*2) 88 - 185VDC, constant load.
(*3) No load - full load, constant input voltage.
(*4) Constant current limiting with automatic recovery.
(*5) Inverter shutdown method, manual reset.
PH150S110 Specifications
PH
150S110
0
20
40
60
80
100
120
Input Voltage (V)
Load (%)
88
82
100
0
20
40
60
80
100
120
−20
0
20
40
60
85 100
Baseplate Temperature (℃)
Load (%)
型名 PH150S110
Derating Curve
(*6) Ratings - Refer to derating curve below.
- Load(%) is percent of maximum output current.
(*7) Heatsink has to be chosen according to instruction manual.
(*8) Refer to instruction manual.
(*9) External components are needed for operation.
(Refer to basic connection and instruction manual.)