WCL488 Series Water Cooled Electronic Loads
Operation & Programming Manual
TDI-Dynaload Division
Page 48
402828, Rev. B1
Power-on Defaults
The following table indicates the factory default conditions are in effect every time the load is
switched on. This can be re-configured by the user in memory location zero (0).
Table M. Power-on Defaults
Parameter
Setting
CI — Constant current setpoint
0
CP — Constant power setpoint
0
CR — Constant resistance setpoint
∞
CV — Constant voltage setpoint
Vmax
DU — Square wave duty cycle
50%
FQ — Square wave frequency
1000 Hz
I1 — First current value
0
I2 — Second current value
0
IL — Current limit
105% of full scale
LOAD — Relay
Open
MODE — Mode
Constant current
P1 — First power value
0
P2 — Second power value
0
PL — Power limit
105% of full scale
R1 — First resistance value
∞
R2 — Second resistance value
∞
RNG — Range
High Volts, High Amps
T1 — First duration
500 microseconds
T2 — Second duration
500 microseconds
TEXT — Text
ON
V1 — First voltage value
Vmax
V2 — Second voltage value
Vmax
VL — Voltage limit
105% of full scale
XM — External modulation
OFF