Configuration
The configuration is realised through the integrated web interface
.
Connect a PC to the system.
System requirements
For commissioning and the operation of the IP video front-door station you need a PC with
the following minimum requirements:
State-of-the-art technology,
operating system: WIN2000 or higher, MAC or Linux with graphical user interface,
network connection to the front-door station
internet browser (Internet Explorer, FireFox, Opera, Safari, Chrome)
Preparing the network connection
To ensure that the front-door station can be addressed after the installation, the front-door
station must be allocated to an IP-address in the address area of your network.
To have access to the configuration of the front-door station, the PC must be equipped
with a network connection and located in the same sub net as the front-door station.
If your network and the front-door stations are working in the 192.168.1 address area (C-
net), you can directly access the front-door station (provided that another device is not us-
ing the same IP-address.)
Otherwise, the used PC is to be adjusted temporarily to an IP-address in the address area
of the front-door station to get a connection.
If several front-door stations in delivery condition be installed in a network, the devices
must be commissioned one after the other and assigned to a free IP-address.
To setup the network connection, you might need administrator rights.
When in delivery condition, the following characters are preset in the front-door station:
IP address: 192.168.1.250, sub net mask: 255.255.0.0,
user: admin, password: 1234
Reset to factory settings
In every menu, the settings can be reset to factory settings, simply by pressing the but-
ton
factory settings
.
Further all settings can be reset with the mode switch:
switch 3: all settings (except the network settings),
switch 4: network settings.