6
Legend button assignment
no reaction - button is not assigned
call up input flat number / telephone number
call up name list (resp. initial character, if configured in this way)
jump to the next character
start entry code number
call up name list (resp. initial character, if configured in this way)
back / repeat entry
delete character to the left of the cursor
back to the idle screen, end voice connection
call the selected call destination (name or flat number)
end and confirm entry
select previous name (line) from the name list
select succeeding name (line) from the name list
call up additional information after a door call (speech channel is busy; serial number 1 and 2 acknowledged)
Legend actions
indoor station(s) is (are) called
breakdown (see page 18)
indoor station could not be called (ring tone is switched
off, indoor station 1 and/or 2)
error
a)
voice connection; speech channel is not busy
temperature sensor was not found (check serial number,
temeperature sensor)
voice connection terminated; speech channel is busy
acknowledgement of indoor station with serial number 1
OK
code number entry
acknowledgement of indoor station with serial number 2
OK
code number known, door opener is triggered
acknowledgement serial number 1 not OK (analogue SN
2)
code number unknown, door opener is not triggered
a) in combination with the following symbols:
The serial number is unknown or no data set is available.
An unknown indoor station has start a voice connection.
No code number entry before pressing the
button or the code number is unknown.
An unknown indoor station is called.
Technical data
supply voltage
+24 V ± 8 % (power supply and control unit)
input current in resting position
I(a) = 0.11 mA, I(P) = 7.8 mA
max. input current:
I(Pmax) = 86 mA
acceptable ambient temperature
-25 ... +55 °C
housing
aluminium,
anodised
display
plastics
buttons
plastics with insert made of aluminium anodised
dimensions (in mm)
H 105 x W 105 x D 22
weight
270
g
3-wire technique necessary!