TCS AMI11603 Product Information Download Page 1

 

 

 

Product information 

Display module LCD graphic, 3 buttons 

AMI11603 

for 256 flats 

 

 
 

 

Note on the validity of this product information 

This product information contains specific information on the modules. It is only valid in combination with 
the enclosed product information Module of the series

AMI in front-door stations. 

 

 

Summary of Contents for AMI11603

Page 1: ...MI11603 for 256 flats Note on the validity of this product information This product information contains specific information on the modules It is only valid in combination with the enclosed product i...

Page 2: ...ing elements 5 Technical data 6 Mountingandinstallation 7 Connecting the lines 7 Example circuit 9 Wiring diagram 9 Initialoperation 10 Operating modes 10 Configuration 11 Factory settings 11 Configur...

Page 3: ...able in the download area at www tcsag de Used symbols and warning notices Symbol signal word Explanation DANGER The signal word describes an endangering with a high level of risk Failure to observe t...

Page 4: ...ctric voltage of 32 V DC at each connection is not to be exceeded Product description Intended use The display module LCD graphic AMI11603is a module of the front door station series AMI The display m...

Page 5: ...rect dial a The EEPROM data base is not compatible with AD1 resp AD2 configuration onl with the configuration software configo update via ISP interface feasible a Options in case of activated function...

Page 6: ...nnel is not busy temperature sensor was not found check serial number temeperature sensor voice connection terminated speech channel is busy acknowledgement of indoor station with serial number 1 OK c...

Page 7: ...onnection to built in door loudspeaker module AMI11100 codelock module AMI11200 and jogwheel module AMI10410 At the built in door loudspeaker module AMI11100 Remove the terminal cover 3 Open the cap o...

Page 8: ...ogwheel module AMI10410 At the TCS BUS speech module AMI11110 Connect the cable of the built in door loudspeaker to the display module Connect the codelock module AMI11200 and the jogwheel mod ule AMI...

Page 9: ...see TCS system manual The TCS system manual can be downloaded at www tcsag de Wiring diagram ISH3030 ISW3030 ISH3030 ISW3030 BVS20 NGV1011 front door station connect to AMI111x0 FAA1100 floor push bu...

Page 10: ...rectly via the codelock module b Only possible when the AD2 mode is activated Transferring the call number is implemented by selecting the name or the flat number Install all AMI modules completely an...

Page 11: ...n you need the maintenance package FBI1210 0 or FBI1200 0 All configuration data and the resident data base are stored on the EEPROM Additionally these data are transferred automatically to the EEPROM...

Page 12: ...it at the front door station ans it is switched off automatically after 30 sec The backlight is activated by one of the following actions pressing a smart key at the display module pressing a button...

Page 13: ...with the selected initial character is marked fig 13 The list of available initial characters is only displayed if the chapter pre selection resident list was activated via the con figuration softwar...

Page 14: ...heel until the required initial character is displayed Confirm your selection with the smart key or The resi dent list is displayed and the first name with the required initial character is marked Bro...

Page 15: ...ected flat number b is called and displayed ill 26 If the telephone does not respond resp the front door station receives no acknowledgement the indication appears fig 26 Fig 24 Calling the flat numbe...

Page 16: ...he code with 1 to 4 digits at the codelock module Confirm your entry with the smart key or the button at the codelock module If the code is valid the door opener is triggered fig 32 If the code is inv...

Page 17: ...le from the mains voltage and pull out all connecting plugs Deinstall the defect display module from the front panel Remove the EEPROM 1 Install the new display module into the front panel Plug the EE...

Page 18: ...change a and P wire or remove short circuit device is in standby mode again EEPROM error defect is missing or plugged incorrectly Ensure that the module is voltage free Plug the EEPROM correctly on t...

Page 19: ...nts Remove stronger stains with a pH neutral household cleaner Conformity Declarations of conformity are available for download under www tcsag de Information on disposal Dispose the device separately...

Page 20: ...r K3 post for 1 to 6 modules ZAU200x Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS T rControlSysteme AG Geschwister Scholl Str 7 39307 Genthin Germany FON 49 0...