新建文件夹
(3)Test and Alignment Specification for NT63
Series (v0 01) 170612
Page 16 of 25
Appendix (3) How to upgrade main SW using USB and RCU
➢
Power on TV.
➢
Copy the SW BIN image “
V8-N563T01-LF1Vxxx.bin
” into USB stick (pen drive) root path.
➢
Plug USB stick to the TV.
➢
Option-->settings--> Support--> Software update -->By USB. TV will find
Vxxx
and please do
“update”.
➢
TV will update SW automatically, and show some notes on TV.
➢
When reflashing is successful, TV should restart automatically after ~4min.
➢
Remember to perform “
Factory menu
Reset ALL
“ and “
Factory menu
Reset Shop
“ and then press RCU
“
OK/
►” key.
➢
Switch off TV by removing AC cord.
➢
Reconnect AC cord to restart TV.
Appendix
(4)
“How to change Project ID with RCU”
➢
Process following subsequence IR codes to change projectID:
MENU+xxx
(xxx:ProjectID, ex: 001)
➢
If it works, the TV will restart automatically.
Appendix
(5)
“How to upgrade CI
+
Key using USB”
➢
Create a new folder named
“
CI+KEY
” on USB stick (pen driver) root path.
➢
Copy corresponding “
*.key
”
files into CIKEY folder.
➢
Under CIKEY folder, create
a new folder named “
backup
” (once the CI key is overwritten, the matching key file
will be moved to this folder)
➢
Plug USB stick to the TV
➢
Go to “
Factory menu
Other
Update CI+ Credential
Update From USB
“ and then press RCU “
OK/
►”
key
The
“Valid” flag should now be enabled (turns to “Yes”), “Custom Code” should display “
TCL
” and “Serial Num.”
field should update with Key number.
➢
Remove USB stick
Note
⑹
:
If unfortunately the process failed, you may need to download new CI key and repeat operation again.
Appendix
(6)
“How to upgrade Netflex ESN using USB”
➢
Under USB root path, create
a new folder named as “
esn
”, then copy corresponding ESN KEY bin files into this
folder;
➢
Under
“
esn
” path, the key should be named as “
nflxk_***
”,like this
,
➢
Plug USB stick to the TV;