ALGORITHMS
M5ALGOIN
Rev 1.7 Page 23
PITCH UP
In order to replay the signal faster, some chosen "parts" have to be repeated simultaneously
with the original signal. This is called LOOP BACK. The selection of these parts are of vital
importance for the quality of the pitch and are completely controlled by the software.
PITCH DOWN
This is the opposite situation where chosen parts of the signal must be skipped. This is called
LOOP FORWARD. Again, the selection of the parts are essential for the quality of the pitch.
To avoid major disturbances caused by the repeating/skipping of parts in the signal, the
distance of the inserted or removed parts must be as short as possible.
EDIT PARAMETERS:
PAGE 1:
MIX
0 - 100 %
Sets the mix between dry and wet signal.
100 % = effect signal only. Mix can be
set to 100 % globally in the G-LEVELS-
menu under UTILITY. Set MIXMODE
WET=MAX
and all dry signals are
"killed" regardless of preset mix settings.
INLEV
off - 0.0 dB
Sets the level of the input to the program
in 0.5 dB steps. The function of the
control is to maximize dynamic range.
Please note that this control is positioned
after the input PPM meter, and will not
affect the input PPM reading, also if
using an analog input, make the analog
input adjustment in the G-LEVELS-
menu under However, if the red
overload LED flashes, turn down INLEV
a couple of dBs. The control does not
affect the bypassed signal level.
Normally, you do not have to change the
factory default setting.
OUTLEV
off - 0.0 dB
Sets the output level of the program in
0.5 dB steps. The function of this control
is to maximize dynamic range by
allowing the program to output
maximum signal to the DA converters. It
affects the output PPM reading. Note
that there is a separate output level
control for adjusting the analog output
Summary of Contents for M5000