DB6 remote control
DB6 English Manual (2014-10-07) 62
For a description of the “Idle” state, see “Idle
state” on page 62.
Select the Preset Bank using the Scene Bank
parameter.
4 Presets DUAL setting
Select one of four Presets using GPI1 and GPI2.
This mode uses simple binary inputs on GPI1
and GPI2 – i.e. 00, 01, 10 and 11.
Select the Preset Bank using the Scene Bank
parameter.
15 Presets DUAL setting
Select one of fifteen Presets using GPI1 and
GPI2.
This mode uses 8-state on GPI1 and binary on
GPI2.
For a description of the “Idle” state, see “Idle
state” on page 62.
In this mode, the Scene Presets are always re-
called from two consecutive banks – e.g. Bank 1
and Bank 2.
Select the Preset Bank pairs (1+2, 3+4 etc.) using
the Scene Bank parameter.
16 Presets DUAL setting
Select one of sixteen Presets using GPI1 and
GPI2.
This mode uses 8-state on GPI1 and binary on
GPI2.
In this mode, the Scene Presets are always re-
called from two consecutive banks – e.g. Bank 1
and Bank 2.
Select the Preset Bank pairs (1+2, 3+4 etc.) using
the Scene Bank parameter.
Idle state
“Idle” denotes GPI control being presently not
active – i.e. the unit can still be controlled as nor-
mal, adjusting parameters and recalling presets
via Icon. However, once a non-idle GPI state is
chosen, the selected Scene preset is recalled,
and normal functionality is blocked (which is also
the case when GPI is engaged in general).
Scene Bank parameter
If you have set the previously described Function
parameter to any value other than “Off”, you can
select the Bank (or Banks) that Presets should
be chosen from using the Scene Bank param-
eter. See the recall modes for a more thorough
explanation.
Status field
The status field is intended for diagnostics dur-
ing the setup of GPI control.
“-“ display
GPI 1 is not enabled, or the incoming voltage is
outside of valid windows. Check the device’s GPI
calibration, the incoming voltage and the general
external GPI setup.
“Idle” display
GPI is not controlling. The incoming GPI voltage
may be at maximum or not connected while the
current setting for the Scene Bank parameter in
the same section includes the “idle” option.
“1 (N/A)” display
No valid User preset is stored in that specific li-
brary location, and therefore GPI is not control-
ling. The behavior of the device is identical to
Idle state.
“1”, “2” … “8” displays
Incoming GPI voltage is within the valid window,
and GPI is controlling Scene Recall. The TC Icon
UI is locked.
Details regarding GPI signals
GPI 1 is receiving fixed-state, latching signals. A
validation process is performed when receiving
a new GPI voltage. The incoming voltage needs
to be within the specific valid window for 500 ms
before the preset change is initiated.
The time required for performing a change de-
pends on the scope of that change – e.g., wether
Summary of Contents for DB6
Page 4: ...Important safety instructions DB6 English Manual 2014 10 07 1 Important safety instructions...
Page 8: ...About this manual DB6 English Manual 2014 10 07 5 About this manual...
Page 10: ...Before you get started DB6 English Manual 2014 10 07 7 Before you get started...
Page 12: ...Unpacking and setup DB6 English Manual 2014 10 07 9 Unpacking and setup...
Page 21: ...DB6 An introduction DB6 English Manual 2014 10 07 18 DB6 An introduction...
Page 36: ...Setting up DB6 DB6 English Manual 2014 10 07 33 Setting up DB6...
Page 42: ...Basic operation DB6 English Manual 2014 10 07 39 Basic operation...
Page 47: ...Accessing DB6 DB6 English Manual 2014 10 07 44 Accessing DB6...
Page 54: ...Setting up audio and syncing DB6 English Manual 2014 10 07 51 Setting up audio and syncing...
Page 61: ...DB6 remote control DB6 English Manual 2014 10 07 58 DB6 remote control...
Page 82: ...Updating DB6 firmware DB6 English Manual 2014 10 07 79 Updating DB6 firmware...
Page 90: ...Icon Setup DB6 English Manual 2014 10 07 87 Icon Setup...
Page 96: ...Loudness Wizard DB6 English Manual 2014 10 07 93 Loudness Wizard...
Page 112: ...Loudness Wizard 2 DB6 English Manual 2014 10 07 109 Loudness Wizard 2...
Page 138: ...LM6 DB6 English Manual 2014 10 07 135 LM6...
Page 164: ...Appendix 2 DB6 GPI O page DB6 English Manual 2014 10 07 161 Appendix 2 DB6 GPI O page...
Page 167: ...Technical specifications DB6 English Manual 2014 10 07 164 Technical specifications...
Page 174: ...Technical specifications DB6 English Manual 2014 10 07 171...