SP60/SP80 User Manual V1.3
TBB Power Co.,Ltd
27
5.0 LCD Menu and Configuration
Some of the configurations were protected by password. The default password was 0000. You
can reset during first installation.
Status
Information
Setting
Control
Event log
05
04
03
01
02
0101
All LCD dot on
Start
0202
Type/mode:
SP80A 48V
Control firmware
version:
0203
00.01.0002
LCD firmware
version:
00.02.0004
0201
2014/05/06 09:05:44
050101
050102
050103
Alarm #25
PV voltage high
Notice #1999
Clock set done
2/3
Alarm #23
Over temperature
1/3
2014/04/05 09:15:15
2013/11/02 19:13:22
3/3
Password:0000
03
password
Equalize battery
0401
<Start>
Alarm
0501
History
0502
Clear alarm
0402
<Start>
050201
Daily logs
050203
Monthly logs
050202
Total
SP 280.0KWH
050204
Life
SP 888.0KWH
Clear history
0403
<Start>
05020101
Today-01
05020102
Peak W 3230W
05020131
Today-31
Peak W 2230W
05020130
05020201
Month-01
05020202
Peak W 3280W
05020212
05020211
Month-12
Peak W 3280W
Battery capacity
Date and time
0303
0302
<100AH>
Change language
0301
<English>
Battery low voltage
0305
<11.8V>
Max charger rate
0306
<15%>
Equalization
remainder
0307
<15days>
Charger floating
voltage
0315
<13.7V>
Constant voltage time
0314
<150mins >
PV and SP
identification
0310
<Array1 >
Temperature
compensation rate
0316
<3.2mv/cell >
PV array power
0309
<120W>
PV array voltage
0308
<80V>
Battery type
0304
<AGM>
Output 80V 60A
Input 120V
Auxiliary output
0311
<Battery low voltage>
Charger equalization
voltage
0317
<15.5V >
Charger constant
voltage
0313
<14.4V >
Equalization time
0318
<30mins >
Change password
0312
0102
PV voltage high
Alarm #25
SP 23.0KWH
SP 23.0KWH
SP 122.3KWH
SP 122.4KWH
0404
Restore factory
settings
<Start>
Fig 5-1Complete Menu Map