Setting Page
Value
Default
Description
PV array voltage
0-150V
72Vdc
set the Vmpp of PV array you installed
PV array power
100-5000W
0
set the power of PV array you installed
PV&SP identification
PV&SP 1-12
PV&SP 1
set the name of this PV array if you have
multiple installed.
Tab5-4 PV array related setting
A
A
u
u
x
x
i
i
l
l
i
i
a
a
r
r
y
y
o
o
u
u
t
t
p
p
u
u
t
t
s
s
e
e
t
t
t
t
i
i
n
n
g
g
The default is no trigger source. Please scroll down to “Set the Auxiliary output” page and
press ENTER button starting the auxiliary output setting
Setting Page
Value
Default
Description
Auxiliary
output
Battery
Voltage Low
+0.1- +0.4Vdc
: +0.2Vdc of
Battery low
voltage you set
it will send signal once the battery
voltage reach the level you set. It
can be used for load management.
High Batt
Temp
45
℃
- 50
℃
50
℃
It can be used to trigger on a
ventilation fan. Do not use this
function if the Temperature sensor
was not installed.
EQ Charging
stage
N/A
Will send signal once EQ charging
was triggered
PV input high
voltage
135Vdc
135Vdc
The figure can’t be reset. This can
be used to trigger on an alarm or
disconnecting the PV array from
the MPPT.
Tab5-5 Auxiliary output setting