![TBB power Kinergier Pro Series Manual Download Page 14](http://html2.mh-extra.com/html/tbb-power/kinergier-pro-series/kinergier-pro-series_manual_4375271014.webp)
Kinergier Pro User Manual
9
Kinergier Pro offers premium charging algorithm for commonly encountered lead acid battery
chemicals including AGM, GEL, Flooded, lead-carbon and Lithium battery which you can set
through LCD interface and TBB Link software.
Lithium Battery Compatible
Kinergier Pro has built-in communication compatible with for Super L lithium battery from TBB.
Manual Equalization
It is strongly recommended to read this section carefully before you start the EQ
charging and don’t leave battery unattended while performing desulfuration.
Always check if your battery supplier recommended EQ charging. Only start when it
is suitable.
If battery type was set at AGM, GEL or Lead-Carbon, this charging profile can’t be
triggered on.
Over a period of time, the cells in a flooded battery can develop uneven chemical states. This will
result in a weak cell which in turn can reduce the overall capacity of battery. To improve the life
and performance of flooded battery, Kinergier Pro includes a manual equalization program that
can be used, if recommended by battery manufacturer. You can initiate the desulfuration program
manually. Once you trigger on the equalization program, Kinergier Pro will perform equalization
charging.
After 30 minutes, it will quit EQ and enter into float charge.
Check electrolyte level and refill battery with distilled water if necessary.
If you want to come to normal charging, you need stop equalization charging and switch off
the unit.
Switch on the unit again, then you will have your equipment back to normal charging.
During equalization, the battery generates potentially flammable gases. Follow all
the battery safety precautions listed in this guide. Ventilate the area around the
battery thoroughly and ensure that there are no sources of flame or sparks in the
vicinity.
Turn off or disconnect all loads on the battery during equalization. The voltage
applied to the battery during equalization may be above the safe levels for some
loads.
Frequency:
Maximum once a month, for heavily used battery, you may wish to equalize your battery. For
battery with light service only need to be equalized every 2-3 months.
Important:
Equalization can damage your batteries if it is not performed properly. Always check battery
fluid before and after equalization. Fill batteries only with distilled water.
Always check the equalization switch is set back to OFF after each time’s equalization.