Page 1: ......
Page 2: ...Kinergier Pro User Manual WARNING HIGH VOLTAGE INSIDE CAUTION THE DC FUSE MUST HAVE BEENTURNED OFF BEFORE SERVICING MADE IN CHINA...
Page 3: ...ual were suitable for Kinergier Pro Inverter Charger This chapter contains important safety and operation instructions Read and keep this User Guide well for later reference The Kinergier Pro Inverter...
Page 4: ...nection compartment 5 2 2 4 Dimension 6 2 3 Function 7 2 3 1 DC Couple and AC Coupled PV System 7 2 3 2 Parallel and Three phase 7 2 3 3 Power control and Power assist 7 2 3 4 System working mode 7 2...
Page 5: ...instruction 19 5 5 2 Parameter set 21 5 6 User control 30 5 6 1 ACin Logic 30 5 6 2 Relay Function 32 5 6 3 AGS Driver 33 5 6 4 ACout2 Logic 35 5 6 5 Screen Set 36 5 6 6 Date Time 36 5 6 7 Trigger Com...
Page 6: ...erwise the Kinergier Pro Inverter Charger would be overheating To avoid fire and electric shock make sure all cables selected with right gauge and being connected well Smaller diameter and broken cabl...
Page 7: ...appliances such as air conditioner water pump washing machine freezer etc With the function of power assist power control it can be used to work with a limited AC source such as generator or limited...
Page 8: ...ture 2 2 1 Front Figure 2 1 Inverter Charger structure in front view 2 2 2 Control panel LCD LED ON OFF MUTE Unlock the fault and alarm Cancel Back Page up Page down Enter LCD Operation Button Figure...
Page 9: ...tem Press the button for more than 2 seconds to scroll the page down Enter into this menu displaying the next level Select and confirm the selection of a menu item Table 2 2 LED directive function LED...
Page 10: ...tor K by default D WCM Connected to the Kinergy data logging stick E Com Sync In Parallel synchronous communication input CAN F Com Sync Out Parallel synchronous communication output CAN G EPO Dry con...
Page 11: ...Kinergier Pro User Manual 6 Figure 2 4 Power terminal 2 2 4 Dimension Figure 2 5 Dimension of Inverter Charger CK4 0M CK5 0M CK4 0S CK5 0S CK6 0S CK8 0S...
Page 12: ...ow automatically using extra power to charge the battery or inverting as the supplement to the grid or generator With this feature you can avoid tripping of shore power MCB or generator oversize 2 3 4...
Page 13: ...le charging program guarantee your battery getting proper maintenance in case of long time connected and less aging in case of long time connected with no use Battery Sample Cable Temperature and volt...
Page 14: ...sulfuration program manually Once you trigger on the equalization program Kinergier Pro will perform equalization charging After 30 minutes it will quit EQ and enter into float charge Check electrolyt...
Page 15: ...um AC input current set by the user Kinergier Pro Inverter Charger will initiate a quick switching to inverter which will guarantee an undisturbed power Upon AC input resume or match the quality it wi...
Page 16: ...When the battery is severely heated the charger will automatically turn off to protect the battery Battery low voltage protection To prevent the permanent damage caused by the over discharge of batter...
Page 17: ...ore flammable explosive or corrosive gases or liquids in the working environment Don t install in a working environment with metal conductive dust Please install the equipment in a location of dry cle...
Page 18: ...d the inverter Step 2 Press the On Off button to turn on the inverter to enter self diagnostic Step 3 Set the parameters following the setup wizard Step 4 Press the On Off button again to turn on the...
Page 19: ...Three Phase Parallel_UVW 1 Phase U L1 2 Phase V L2 3 Phase W L3 Parallel_Addr 1 2 3 if Parallel_System 2 if Parallel_System 1 Solar_System 0 N A 1 DC Couple 2 AC Couple 3 DC AC Couple MPPT_CHG_Num 1...
Page 20: ...n U_ACin 1005W P_ACin 5100W User Control Up Down Enter Back Enter Back E_ACout_Consume 0 9kWh E_ACin_Consume 3 9kWh E_ACin_Feedback 1 2KWh 0 error 0 warning 2019 03 02 10 30 MPPT 1 Warn 20 Para_System...
Page 21: ...rface displaying data of the equipment The default interval time is 5S and the time can be set manually When pressing UP and Down to turn the pages it will stay on the chosen page for 30S and the time...
Page 22: ...such as IG PV inverter Solar Mate MPPT or Battery Guard BGK module you can read the data through this screen as well Running Data BAT Inverter BGK Module MPPT Charger PV Inverter WCM INFO After select...
Page 23: ...3 109 V 2 100 29 BGK Balancer Upper 13 013 V Lower 13 013 V T_Bat 32 PWM 37 WCM INFO Networking OK Signal Stre 100 Server Connect Theta 9000 00 06 0003 ck123452123406 Statistic Data Enter this page yo...
Page 24: ...2019 04 22 15 31 INV Err 109 INV Err 109 Output_ShortCut System Info Enter this page you can check the manufacturing data of this Kinergier Pro inverter including serial number software version and f...
Page 25: ...er button to activate the entering 3 Press UP and Down button to choose digit you want to put 4 Press Enter button to confirm this digit 5 After enter all four digits please press Back button and Ente...
Page 26: ...ree phase systems When you are composing a single phase system max 3 units of Kinergier Pro can be connected together When you are composing a three phase system max 9 units of Kinergier Pro can be co...
Page 27: ...able for DC Coupled PV System Default 1 PV_Inverter_Num 1 2 Number of IG PV inverter connected Only applicable for AC Coupled PV System Default 1 FREQ_Drop Set Drop_Start_FREQ 50 1 51 0Hz 50Hz 60 1 61...
Page 28: ..._Relay 0 Disable 1 Enable The neutral output of inverter is automatically connected to earth upon no external AC sources is available Disable Neutral grounding is disable Enable Neutral grounding is e...
Page 29: ...System Default 0 Default EPO_Function_EN 0 Disable 1 Enable Whether to enable the EPO Function Disable Disable the EPO Funciton Enable External signal will turn off the inverter displaying fault by L...
Page 30: ...ery_AH 50 5000AH Set the battery capacity not applicable to TBB SUPER L lithium battery Default 200AH Battery type Description The following parameters are based on the 12Vdc battery No Battery Type A...
Page 31: ...changed U_Float_CHG This value will be affected when you change the battery type The float charging voltage voltage mentioned here refers to the voltage of 12Vdc battery Note This value will be affect...
Page 32: ...TBB SUPER L mode The inverter will trigger a warning when the SOC is under the setting value Default 20 SOC_Low_Protect 5 40 Can be set in TBB SUPER L mode The inverter will trigger a warning when th...
Page 33: ...d traction battery Default 30min 5 5 2 4 Para_Inverter Para_Inverter You can configure the output of the inverter through this menu Para_Inverter Item Setting range Description INV_Output_VOLT 200 240...
Page 34: ...it_Cur PowerAssist 5 50A The allowed maximum current for the AC in input Note Once set up the inverter will only use the extra power to charge the battery And once the input current of ACin reaches th...
Page 35: ...Relay Logic ACout 2 Logic ACin Logic Relay Logic ACout2 Logic Screen Set Date Time Trigger Command User Control 5 6 1 ACin Logic With this menu you could set up the working logic for Kinergier Pro wo...
Page 36: ...e used in area where they have peak off peak tariff policy 3 Ubat Ctrl This is an advanced mode base on BATT First Under this mode some energy can be reserved as backup power in case of grid failure U...
Page 37: ...nectSet Back Connect Ubat 11 5V Disconnect Ubat 13 5V Connect Delay 30s Disonnect Delay 180s This mode is applicable with TBB SUPER L lithium battery This mode is not applicable with TBB SUPER L lithi...
Page 38: ...Define Relay2 Define Display if Function Mode is 1 User Define AGS Logic Display if Function Mode is 2 AGS Driver 5 6 3 AGS Driver With this menu relay 1 and relay 2 will be programmed to control the...
Page 39: ...hen the AGS logic is off it displays the manual triggering of the AGS start interface and it will enter the AGS charging logic after it is triggered 2 2 When the AGS logic is on it displays manual tri...
Page 40: ...0s CHG Stop Delay 180s Load AGS Logic 1 Enable This mode is applicable to TBB SUPER L lithium battery 5 6 4 ACout2 Logic Item Setting range Description ACout2 Logic Logic Mode 0 Default 1 Ubat SOC Ctr...
Page 41: ...B SUPER L lithium battery ACout2 OFF SOC Turn off the SOC threshold of the ACout2 ACout2 ON SOC Turn on The SOC threshold of the ACout2 ACout2 OFF Ubat Turn off the voltage threshold of the ACout2 ACo...
Page 42: ...OT Transformer s temperature is too high Too high ambient temperature 107 Sam_HD_Fault Sampling is abnormal Restart the inverter Contact your installer if it still exists 108 EEPROM_Fail ROM is abnorm...
Page 43: ...perature 309 PSU_LV Auxiliary power supply is abnormal Restart the MPPT Contact your installer if the error still exists 310 PSU_LV_HD Auxiliary power supply is abnormal hardware 311 Sam_HD_Fault Samp...
Page 44: ...sts 009 ParConnect_Err Parallel connect is abnormal Check the connection of parallel communication cable 010 ParComm_Err CAN communication is abnormal Check the parallel parameter setting 011 Par_ID_C...
Page 45: ...installer if the fault still exists 206 T_BAT_OT Battery temperature is too high Check battery sensor connection Check battery temperature Check battery connection 207 Fan_Fault Fan is abnormal 1 Chec...
Page 46: ...ommunication with inverter is abnormal 057 EXT_Comm Fail Communication among Lithium modules is abnormal 058 SOC_Low Lithium module s SOC is too low 6 2 4 BGK Warning No Warning Code Description 601 U...
Page 47: ...55 2VDC Battery types AGM GEL OPZV Lead Carbon Li ion Flooded TBB SUPER L Battery Charge current 120A 150A 55A 70A 80A 110A Temperature compensation Yes General data AC Out Current AC Out1 Current 50...
Page 48: ...Kinergier Pro User Manual 43...