Seite 20 von 45
If a sequence of frequencies with square wave form
should be entered (for example 1,000, 2,000 and
5,000Hz), the MEMO function can be used to input
the whole sequence.
-
select the wave form by touching
-
select “123” for numerical input
-
input <1>, <0>, <0>, <0>, <E>
-
press
to store 1,000Hz. This frequency now
occupies memory position ‘01’. The memory counter
opens position ‘02’.
-
input <2>, <0>, <0>, <0>, <E>
-
press
to store 2,000Hz. This frequency now
occupies memory position ‘02’. The memory counter
opens position ‘03’.
-
input <5>, <0>, <0>, <0>, <E>. This frequency is
stored in memory position ‘03’ without touching
MEMO, since it is the last value and no further
memory position needs to be prepared.
It is possible to check the input of the frequencies
with the icon’s “PREV” and “NEXT”.
If you want to sweep in the range between value 2
and 3 (in our example 2000 to 5000) go to memory
position ‘02’ and touch the line “Sweep To Next”. The
device calculates the steps for the sweep and
performs it for the time assigned to memory position
‘02’.
If you want to sweep longer than the time assigned
to an individual frequency:
Touch the tab SETUP.
Touch the icon “TIMER”.
Touch ‘50’ to switch the “50 TIMER”-function ON.
Touch the icon “PREV” until the memory position
counter shows ‘02’.
Enter the new time and confirm with ‘E’.
Touch the tab THERA.
Touch the icon “GO” to play back the content of all
memory positions with a frequency value greater
than 0.