OPERATING PROCEDURES
6-9
PH61 Peristaltic Pump
Operating Procedures
6
9.
Press the WASH key. This will cause the cleaning/
sanitizing solution in the freezing cylinder to contact
all areas of the freezing cylinder. Allow the solution to
agitate for 5 minutes. (See Figure 6-37.)
.
Figure 6-37
10. With a pail beneath the door spout, open and close
the draw valve six times.
11. Press the PUMP key to sanitize the inside of the
air/mix pump.
12. Open the draw valve and draw off all the remaining
cleaning/sanitizing solution.
13. Press the WASH and PUMP keys to stop the Wash
and Pump modes. Close the draw valve.
Figure 6-38
Important! Make sure your hands are clean and
sanitized before going on in these instructions.
14. Place the agitator on the agitator driveshaft housing.
Figure 6-39
Note: If the agitator paddle should stop turning
during normal operation, with sanitized hands,
remove the agitator from the agitator driveshaft
housing and brush-clean with sanitizing solution.
Install the agitator back onto the agitator driveshaft
housing.
15. Remove the restrictor cap.
16. Return to the machine with a small amount of
sanitizing solution. With a pail below the door spout,
dip the door-spout brush into the sanitizing solution
and brush-clean the syrup ports in the freezer door,
door spout, bottom of the driven spinner, spinner
blade, and syrup line fittings. To ensure sanitary
conditions are maintained, brush-clean each item for
60 seconds, repeatedly dipping the brush in
sanitizing solution.
17. With the syrup-port brush, brush each syrup-port
hole 10 to 15 times. Dip the brush in sanitizing
solution before brushing each port.
18. Fill the squeeze bottle with cleaning/sanitizing
solution. With a pail beneath the door, insert the tube
end of the squeeze bottle into the syrup port and
squeeze the bottle firmly. This action will force
solution out of the adjacent port and down around the
spinner. This procedure should be performed for at
least 10 seconds per port.
19. Install the syrup valves and the restrictor cap.
Summary of Contents for PH61
Page 8: ...1 4 TO THE INSTALLER PH61 Peristaltic Pump To the Installer 1 Notes ...
Page 14: ...3 4 SAFETY PH61 Peristaltic Pump8 Safety 3 Notes ...
Page 32: ...5 10 USER INTERFACE PH61 Peristaltic Pump User Interface 5 Notes ...
Page 56: ...6 24 OPERATING PROCEDURES PH61 Peristaltic Pump Operating Procedures 6 Notes ...
Page 64: ...9 2 PARTS REPLACEMENT SCHEDULE PH61 Peristaltic Pump Parts Replacement Schedule 9 Notes ...
Page 72: ...11 4 LIMITED WARRANTY ON PARTS PH61 Peristaltic Pump Limited Warranty on Parts 11 Notes ...