USER INTERFACE
5-5
PH61 Peristaltic Pump
User Interface
5
The next display is the screen which will appear after the
BRUSH CLEANING message and illustrates that the
control is in the OFF mode and the machine needs to be
disassembled and brush-cleaned.
Soft Lock
: If a Heat Treatment cycle has not been
initiated within the last 24 hours, all four LEDs on the
front of the machine will light and a message will appear
on the LCD. Line 3 of the LCD will indicate the reason the
message appears. Following are the various messages
that appear on line 3:
1.
POWER SWITCH OFF: Power switch was in the
OFF position.
2.
MIX OUT PRESENT: There was a MIX OUT
condition.
3.
AUTO OR STANDBY OFF: The machine was not in
the Auto or Standby mode.
4.
NO HEAT CYCLE TRIED: A Heat Treatment cycle
was not attempted in the last 24 hours. AUTO HEAT
TIME was advanced, a power loss was experienced
at the time the cycle was to occur, or there was a
Heat cycle failure not due to a thermistor failure.)
If the following screen appears, a soft lock has occurred
during the Heat Treatment cycle:
If the temperature of the product has not fallen below
41°F (5°C) by the end of the Cool cycle, the following
screen will appear:
Press the SEL key to advance to the next display.
When one of these messages appears, automatic freezer
operation cannot take place until the freezer is
disassembled and brush-cleaned or has completed a
Heat Treatment cycle. The next display will instruct the
operator to start a Heat Treatment cycle manually (by
pressing the AUTO key) or to disassemble and
brush-clean the freezer. If the AUTO key is pressed, the
freezer will automatically start the Heat Treatment cycle
and only the Heat cycle LED will light.
If the WASH key is pressed, the next display will appear
and the freezer will have to be disassembled and
brush-cleaned.
NO AUTO OPERATION
ALLOWED UNTIL
BRUSH CLEANING
PRESS WASH KEY
MODE: OFF
HOPPER TEMP: 45.0 F
FREEZER LOCKED
NO HEAT TREAT START
BECAUSE
VARIABLE MESSAGE
PRESS SEL KEY
HEAT TREAT CYCLE
FAILURE
FREEZER LOCKED
PRESS SEL KEY
PRODUCT OVER TEMP
FREEZER LOCKED
PRESS SEL KEY
NO AUTO OPERATION
ALLOWED. PRESS
AUTO FOR HEAT CYCLE
WASH TO BRUSH CLEAN
Summary of Contents for PH61
Page 8: ...1 4 TO THE INSTALLER PH61 Peristaltic Pump To the Installer 1 Notes ...
Page 14: ...3 4 SAFETY PH61 Peristaltic Pump8 Safety 3 Notes ...
Page 32: ...5 10 USER INTERFACE PH61 Peristaltic Pump User Interface 5 Notes ...
Page 56: ...6 24 OPERATING PROCEDURES PH61 Peristaltic Pump Operating Procedures 6 Notes ...
Page 64: ...9 2 PARTS REPLACEMENT SCHEDULE PH61 Peristaltic Pump Parts Replacement Schedule 9 Notes ...
Page 72: ...11 4 LIMITED WARRANTY ON PARTS PH61 Peristaltic Pump Limited Warranty on Parts 11 Notes ...