6-8
OPERATING PROCEDURES
PH61 Peristaltic Pump
Operating Procedures
6
13. Slide the large black O-ring and the two smaller black
O-rings into the grooves on the driveshaft.
Thoroughly lubricate the O-rings and shaft.
Do not
lubricate the hex end of the shaft. (See Figure 6-34.)
Figure 6-34
14. Install the hex end of the driveshaft into the drive hub
at the rear wall of the mix hopper. (See Figure 6-35.)
Figure 6-35
Note: For ease in installing the pump, put the ball
crank of the driveshaft in the 3 o'clock position.
Sanitizing
1.
Prepare a 2.5 gal. (9.5 L) pail of cleaning/sanitizing
solution with an active chlorine concentrate of 100 to
200 ppm (parts per million) approved for use by your
company. Use warm water and follow the cleaning/
sanitizing solution manufacturer's specifications.
2.
Pour the solution over all parts in the bottom of the
mix hopper and allow it to flow into the freezing
cylinder.
Note:
You have just sanitized the mix hopper and parts.
Therefore, make sure your hands are clean and sanitized
before going on in these instructions.
3. Using the white hopper brush, clean the mix-level
sensing probes, mix hopper, mix inlet hole, outside of
the agitator driveshaft housing, agitator, air/mix
pump, pump clip, mix feed tube, and cotter pin.
4. Install the air/mix pump assembly at the rear of the
mix hopper. To position the pump on the drive hub,
align the drive slot in the piston with the drive crank of
the driveshaft. Secure the pump in place by slipping
the pump clip over the collar of the pump, making
sure the clip fits into the grooves in the collar.
Figure 6-36
Important! Install the pump end of the mix feed tube and
secure with the cotter pin. Failure to follow this instruction
could result in sanitizer spraying on the operator.
5. Prepare another 2.5 gal. (9.5 L) pail of the cleaning/
sanitizing solution.
6. Pour the solution into the mix hopper until it is within
1 in. (25 mm) of the top of the hopper.
7. Using the white hopper brush, scrub the exposed
sides of the hopper.
8. Place the power switch in the ON position.
Apply the appropriate
Taylor approved food safe lubricant.
HP
12311
Summary of Contents for PH61
Page 8: ...1 4 TO THE INSTALLER PH61 Peristaltic Pump To the Installer 1 Notes ...
Page 14: ...3 4 SAFETY PH61 Peristaltic Pump8 Safety 3 Notes ...
Page 32: ...5 10 USER INTERFACE PH61 Peristaltic Pump User Interface 5 Notes ...
Page 56: ...6 24 OPERATING PROCEDURES PH61 Peristaltic Pump Operating Procedures 6 Notes ...
Page 64: ...9 2 PARTS REPLACEMENT SCHEDULE PH61 Peristaltic Pump Parts Replacement Schedule 9 Notes ...
Page 72: ...11 4 LIMITED WARRANTY ON PARTS PH61 Peristaltic Pump Limited Warranty on Parts 11 Notes ...