USER INTERFACE
5-3
PH61 Peristaltic Pump
User Interface
5
Operating Screen Descriptions
When the machine is powered, the system will initialize.
The screen will display INITIALIZING. There are four
types of data the system will check: LANGUAGE,
SYSTEM DATA, CONFIG DATA, and LOCKOUT DATA.
During the INITIALIZING... LANGUAGE screen, the
alarm will be on. If the system data, configuration data, or
lockout history data has become corrupt, the following
screen will alert the operator that the system settings
may have been changed:
Once the system has initialized, the SAFETY TIMEOUT
screen is displayed and the alarm is turned on.
This screen will be displayed, with the alarm on, for
60 seconds or until any key is pressed.
After the safety timeout has been completed and the
power switch is OFF, one of the following screens is
displayed.
The first screen is displayed if the machine is not in a
brush-clean state. If any of the requirements for a
brush-clean have not been met, the time displayed will
remain at 5 minutes. When all the requirements for a
brush-cleaning are met and the 5 minutes expire, the
screen will change to the second screen, which is the
standard POWER SWITCH OFF screen.
When the power switch is set in the ON position, the
system mode of operation screen is displayed. In this
example, the machine is ON but no mode of operation
has been selected. The second line of the display
indicates whether there is a sufficient supply of mix in the
hopper or if there is a LOW or OUT mix condition. The
third line of the display shows the temperature of the mix
hopper. After pressing the AUTO key, the last line of the
display shows the month and date (MM = month,
DD = day) that the machine needs to be disassembled
and brush-cleaned.
The next display indicates the freezer is operating in two
different modes. The following information is given:
The machine is operating in the Wash and Pump modes,
the temperature of the mix hopper is 40°F (4.4°C), and
the machine needs to be brush-cleaned on October 31
st
.
NVRAM FAULT
RESET TO DEFAULTS
PRESS SEL KEY
SAFETY TIMEOUT
ANY KEY ABORTS
POWER SWITCH OFF
TIME: 4:40
HOPPER: 62.1
BARREL: 67.7
POWER SWITCH OFF
- = - = - = - = - = -
UNIT CLEANED
MODE: OFF
HOPPER TEMP: 35.5F
UNIT CLEANED
MODE: WSH-PMP
HOPPER TEMP: 40.0 F
BRUSH CLEAN ON: 10/31
Summary of Contents for PH61
Page 8: ...1 4 TO THE INSTALLER PH61 Peristaltic Pump To the Installer 1 Notes ...
Page 14: ...3 4 SAFETY PH61 Peristaltic Pump8 Safety 3 Notes ...
Page 32: ...5 10 USER INTERFACE PH61 Peristaltic Pump User Interface 5 Notes ...
Page 56: ...6 24 OPERATING PROCEDURES PH61 Peristaltic Pump Operating Procedures 6 Notes ...
Page 64: ...9 2 PARTS REPLACEMENT SCHEDULE PH61 Peristaltic Pump Parts Replacement Schedule 9 Notes ...
Page 72: ...11 4 LIMITED WARRANTY ON PARTS PH61 Peristaltic Pump Limited Warranty on Parts 11 Notes ...