background image

Table of Contents

062179-S

i

Section 1: Introduction

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Model C712 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Model C713 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Running Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
General Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Environmental Notices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15

Section 2: Controls

Universal Control Programming  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Power Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Pump Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
Beater Stir Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Setting Viscosity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17
Jumper Pin Charts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18
Control Overview - UVC4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
Universal Control Board - UVC4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
C712/C713 UVC4 Update Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
Refrigeration Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26
Refrigeration System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27

Section 3: Troubleshooting

General Troubleshooting Guide  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Electrical Troubleshooting Guide  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
C712/C713 Electrical Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
Pump Style Freezer Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Bacteria Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8

Section 4: Parts

Parts Warranty Explanation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Model C712 Exploded View  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Operator Parts (Model C712) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Model C713 Exploded View  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Operator Parts (Model C713) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Control A. - X67560-27 (Model C712). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
Control A. - X67561-27-(Model C713)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
Box A.-Cap & Relay - X6540227SP - (Model C712 & C713/Bristol). . . . . . . . . . . . . . 4-17
Box A.-Cap & Relay - X81081-27 (Model C713/Copeland)  . . . . . . . . . . . . . . . . . . . . 4-18
Pump A.-Mix Simplified - X57029- (Model C712) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
Door and Beater Assembly (Model C712)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20

Summary of Contents for C712

Page 1: ...SERVICE MANUAL Model C712 C713 Soft Serve Freezers 6 15 05 Original Publication Updated 7 31 2018 Original Service Instructions 062179 S ...

Page 2: ...e s are considered to be the original set of instructions June 2005 Taylor Company Updated 7 31 2018 062179 S Any unauthorized reproduction disclosure or distribution of copies by any person of any portion of this work may be a violation of Copyright Law of the United States of America and other countries could result in the awarding of Statutory Damages of up to 250 000 17 USC 504 for infringemen...

Page 3: ...25 Refrigeration Schematic 2 26 Refrigeration System Components 2 27 Section 3 Troubleshooting General Troubleshooting Guide 3 2 Electrical Troubleshooting Guide 3 5 C712 C713 Electrical Troubleshooting Guide 3 6 Pump Style Freezer Troubleshooting 3 7 Bacteria Troubleshooting 3 8 Section 4 Parts Parts Warranty Explanation 4 2 Model C712 Exploded View 4 3 Operator Parts Model C712 4 6 Model C713 Ex...

Page 4: ...713 4 23 Rail Syrup X63883 27 Optional 4 24 Switch A Dual Lever X69838 Model C712 C713 4 25 Actuator A Draw Switch X69835 Model C712 C713 4 26 Blower A X53725 27 Model C712 C713 4 27 Condenser A X68077 27G Model C712 C713 4 28 Accessories 4 29 Brushes Model C712 C713 4 30 Section 5 Parts List Section 6 Wiring Diagrams ...

Page 5: ...Section 1 1 1 Models C712 C713 Introduction Introduction Safety Model C712 Specifications Model C713 Specifications Running Specifications General Installation Instructions User Interface User Interface ...

Page 6: ...perate the machine with larger fuses than specified on the data label Stationary machines which are not equipped with a power cord and plug or other device to disconnect the machine from the power source must have an all pole disconnecting device with a contact gap of at least 0 125 in 3 mm installed in the external installation Machines that are permanently connected to fixed wiring and for which...

Page 7: ...tall this machine in a location where its use and maintenance is restricted to trained personnel Failure to comply may result in personal injury WARNING This machine must NOT be installed in an area where a water jet or hose can be used NEVER use a water jet or hose to rinse or clean the machine Failure to follow this instruction may result in electrocution NOTICE Cleaning and sanitizing schedules...

Page 8: ... mm is required around all sides Install the deflector provided to prevent recirculation of warm air Water Cooled Water inlet and drain connections under the side of the base 1 2 in FPT Dimensions Width 25 7 16 in 646 mm Height 60 in 1524 mm Depth 36 3 16 in 919 mm Floor Clearance 4 3 4 in 121 mm Mounted on standard casters Approximate Weights Net 777 lbs 352 kgs Crated 855 lbs 388 kgs Volume 68 4...

Page 9: ...INTRODUCTION 1 5 Models C712 C713 Introduction 1 Figure 1 1 ...

Page 10: ... mm is required around all sides Install the deflector provided to prevent recirculation of warm air Water Cooled Water inlet and drain connections under the side of the base 1 2 in FPT Dimensions Width 25 7 16 in 646 mm Height 60 in 1524 mm Depth 36 3 16 in 919 mm Floor Clearance 4 3 4 in 121 mm Mounted on standard casters Approximate Weights Net 733 lbs 333 kgs Crated 810 lbs 367 kgs Volume 67 5...

Page 11: ...INTRODUCTION 1 7 Models C712 C713 Introduction 1 Figure 1 2 ...

Page 12: ...in the Auto mode Be sure to allow adequate time for the pressure to stabilize Low Side Suction Suction pressure equals expansion valve setting High Side Discharge High side pressure varies for air cooled machines depending on the ambient temperature Table 1 3 Water Valve On a water cooled machine the water valve should be set to maintain a compressor head pressure of 255 psi 1 758 kPa Water Valve ...

Page 13: ... hose to rinse or clean this machine Using a water jet or hose on or around this machine may result in the electrocution of the user or damage to the machine CAUTION This machine must be installed on a level surface to avoid the hazard of tipping Extreme care should be taken in moving this machine for any reason Two or more persons are required to safely move this machine Failure to comply may res...

Page 14: ...rovided with an equipotential grounding lug that is to be properly attached to the rear of the frame by the authorized installer The installation location is marked by the equipotential bonding symbol 5021 of IEC 60417 1 on the removable panel and the frame WARNING Avoid injury DO NOT attempt any repairs unless the main power supply to the machine has been disconnected DO NOT operate the machine w...

Page 15: ... outlet fitting to an open trap drain IMPORTANT A backflow prevention device is required on the incoming water connection side Please see the applicable national state and local codes for determining the proper configuration Refrigeration CAUTION In consideration of our environ ment Taylor uses only earth friendly HFC refrigerants The HFC refrigerant used in this machine is R404A This refrigerant ...

Page 16: ...el This deactivates the safety feature which prevents the operation of the machine when the door is not installed 3 Place the power switch in the ON position 4 Press the Wash symbol This activates the beater motor only 5 Look into the freezing cylinder The drive shaft should be turning clockwise 6 Press the Wash symbol again to stop the beater motor To correct rotation on a single phase machine ex...

Page 17: ...erants The HFC refrigerant used in this machine is R404A This refrigerant is generally considered nontoxic and nonflammable with an ozone depleting potential ODP of zero 0 However any gas under pressure is potentially hazardous and must be handled with caution NEVER fill any refrigerant cylinder completely with liquid Filling the cylinder to approximately 80 will allow for normal expansion IMPORTA...

Page 18: ... this fact known to any technicians they employ It should be noted that Taylor does not warrant the refrigerant used in its equipment For example if the refrigerant is lost during the course of ordinary service to this machine Taylor has no obligation to either supply or provide its replacement either at billable or unbillable terms Taylor does have the obligation to recommend a suitable replaceme...

Page 19: ...es not have the Mix Pump Button 3 2 3 6 4 5 11 7 1 8 9 10 5 6 4 Item Description 1 Power Switch 2 Liquid Crystal Display LCD 3 Buttons 4 Mix Out Indicator 5 Standby Button Item Description 6 Mix Low Indicator 7 Select Button 8 Service Menu Button 9 Brush Clean Counter 10 Arrow Buttons 11 Wash Button ...

Page 20: ...ure of the mix in the hopper Indicator Lights MIX LOW When the Mix Low indicator is illuminated the mix hopper has a low supply of mix and should be refilled as soon as possible MIX OUT When the Mix Out indicator is illuminated the mix hopper has been almost completely exhausted and has an insufficient supply of mix to operate the freezer At this time the Auto mode is locked out and the freezer wi...

Page 21: ...ing properly touch the Wash button to cancel the cycle Touch the Auto button to resume normal operation If the freezer shuts down again contact your authorized service technician Air Mix Pump Reset Mechanism C712 Only The RESET buttons for the pumps are located in the rear panel The reset protects the pump from overloading Should an overload occur the reset mechanism will trip To reset the pump pr...

Page 22: ...1 18 INTRODUCTION Models C712 C713 Introduction 1 Notes ...

Page 23: ...al Control Programming Power Interrupt Pump Operation Timers Beater Stir Cycles Setting Viscosity Jumper Pin Charts Control Overview UVC4 Universal Control Board UVC4 C712 C713 UVC4 Update Instructions Refrigeration Schematic Refrigeration System Components ...

Page 24: ...re in a menu If a language has been selected the machine is powered down The machine should not ask for a language unless there is another language initialization fault English is the factory default setting System Data System data is protected separately from the rest of the data in memory System data includes variables that change frequently such as the mode the machine is in lockout status serv...

Page 25: ...W increases the value above the cursor and is used to scroll upward in text displays DOWN ARROW decreases the value above the cursor and is used to scroll downward in text displays SEL advances the cursor position to the right and is used to select menu options There is a 2 minute time out in effect during the Manager s Menu While in the Manager s Menu if no activity occurs within a 2 minute perio...

Page 26: ...nager s Menu and return the control panel buttons to normal operation Servings Counter The SERVINGS COUNTER screen is used to reset the servings counter to zero The SERVINGS COUNTER automatically resets to zero when the machine is brush cleaned Figure 2 10 Reset the SERVINGS COUNTER by pressing the SEL button to advance to the next screen Press the Up Arrow button to move the arrow to Yes and then...

Page 27: ... displays the DST START WEEK screen Pressing the Up or Down button will move the arrow to the appropriate week for the start of DST Figure 2 18 Pressing the SEL button next to the appropriate week will display the DST END MONTH screen Press the Up or Down button to move the arrow to the appropriate month for the end of DST Figure 2 19 Pressing the SEL button next to the appropriate month will disp...

Page 28: ...s Menu The control panel icons for Mix Low and Mix Out will illuminate as the mix level drops in the hopper but the audible tone will be disabled Fault Description The LCD is located on the front control panel During normal operation the display is blank The display is used to show menu options and notifies the operator if a fault is detected On international models the display will indicate the t...

Page 29: ...ore than 4 hours following a power failure L R HPR 59F 15C The mix temperature in the hopper exceeded 59 F 15 C L R BRL 59F 15C The mix temperature in the hopper exceeded 59 F 15 C L R COMP ON TOO LONG The compressor run time exceeded the 11 minute timer Note Refer to your local health codes regarding temperature recommendations for procedures to follow if these fault screens appear Lockout Histor...

Page 30: ... COMMUNICATIONS FAILURE during this time Service Menu The Service Menu option allows authorized service technicians to access and modify critical operating parameters for the machine The access code for the Service Menu is 5 2 3 1 Service Menu Options The Service Menu screen includes the following options which are also displayed in the Manager s Menu See page 2 3 EXIT FROM MENU SERVINGS COUNTER S...

Page 31: ...Up Arrow button moves the V one position to the right warmer Pressing the Down Arrow button moves the V one position to the left cooler Pressing the SEL button stores the value of the setting and returns to the Service Menu screen The temperature differential is 2 F 1 C for the hopper temperature Viscosity Setting This option allows the service technician to adjust the viscosity at which the compr...

Page 32: ...turns to the Service Menu screen Mix Pump Off Delay C712 Only This option allows the technician to set the amount of time that the mix pump runs after the draw valve has closed switch opened After selecting the appropriate side of the machine the following screen is displayed Figure 2 41 Pressing the Up or Down Arrow button increases or decreases the time delay by one second respectively Pressing ...

Page 33: ...Nederlands Netherlands Italiano Italian Portuguese Polski Polish and Russian Manual Control This option allows the technician to start and stop button components to test their performance When selected manually power will be supplied to each component until the technician selects OFF or exits the screen The technician must manually select OFF or exit the menu EXIT L BEATER MOTOR L COMPRESSOR L MIX...

Page 34: ...ill allow the service technician to clear all RAM memory This screen was added because it will not be possible to remove the RAM chip on future iterations of the UVC3 control The machine must be in a Unit Cleaned status in order to restore the default settings Selecting this option in the menu will display a screen asking ARE YOU SURE See Figure 2 52 Figure 2 52 Moving the cursor to YES and select...

Page 35: ... minute countdown timer Note The criteria in Steps 1 3 must be met simultaneously for 5 minutes These criteria will be met when the machine is properly brush cleaned according to the Taylor Operator s Manual Completion of a successful brush clean resets the Brush Clean Cycle timer and removes the locked condition A screen showing the status of the elements required for a brush clean is displayed w...

Page 36: ...to the Standby mode of operation the mix pump will not be active Mix Pump Draw Timer During the Auto mode the mix pump will operate for 5 to 30 seconds after every draw of product The factory setting is 10 seconds Figure 2 56 1 8 2 3 4 5 7 6 Item Description Part No 1 Screw 1 4 20x 3 4 Socket 020128 2 2 Seal Motor Reducer Input Shaft 048836 3 Seal Motor Reducer Output Shft 048837 4 Nut Pump Sleeve...

Page 37: ...ut not from Standby Mix Draw Timer During the Auto mode the mix pump will run for 5 to 30 sec every time product is drawn from the machine The factory setting is 10 sec Safety Timeout Once power is applied to the machine a 60 second timer places the machine in an Idle state The tone is turned on in 0 5 second intervals and a Safety Timeout message appears on the LCD This timer can be aborted by to...

Page 38: ...tivates the beater motor for 6 seconds After the stir cycle the process will repeat itself the timer will count down 2 minutes and the beater will run for 6 seconds Hopper Temperature The hopper temperature setpoint range is 29 5 F to 39 F 1 4 C to 3 9 C In the Auto or Standby mode the compressor starts when the hopper temperature is above the setpoint and stops when the hopper temperature reaches...

Page 39: ...ge load increases When the amperage load reaches the setpoint the refrigeration cycle discontinues The factory setting setpoint for soft serve viscosity is 2 8 amps The amperage measurement is determined by monitoring the L1 leg of power being delivered to the beater motor To adjust the serving viscosity it may be necessary to raise or lower the amperage setpoint Adjust in increases of 0 1 amps Th...

Page 40: ...ER C712 C713 Left Interface X59485 SER Force Brush Clean Status W2 Syrup Heater Enable W3 Open All Left Solenoids W4 Open All Right Solenoids W4 Clock Calendar Override W5 Force Glycol Pump On 59F Fault Detection Enable W2 Standby Stir Cycle Disable W5 Reduced Mix Low Sensitivity W6 W6 Reduced Mix Out Sensitivity W7 W7 7C 45F 90 Min Cool Phase Unused W1 W1 Unused W3 Disable Control Panel Self Serv...

Page 41: ...ure C712 C713 Left Interface X59485 SER C712 C713 Right Interface X59485 SER Force Brush Clean Status W2 Syrup Heater Enable W3 Open All Left Solenoids W4 Open All Right Solenoids W4 Clock Calendar Override W5 Force Glycol Pump On 59F Fault Detection Enable W2 Standby Stir Cycle Disable W5 Reduced Mix Low Sensitivity W6 W6 Reduced Mix Out Sensitivity W7 W7 7C 45F 90 Min Cool Phase Unused W1 W1 Unu...

Page 42: ...2 20 CONTROLS Models C712 C713 Controls 2 Control Overview UVC4 Figure 2 58 ...

Page 43: ...identifies the connections on the board Important See UVC4 Electrostatic Discharge and Proper Handling Procedures on page 2 22 before handling a UVC4 board 1 8 6 5 7 9 3 2 4 Item Jumper No Function 1 J1 5 VDC power input 2 J2 18 pin power loss analog cable 3 J4 USB program port 4 J7 18 pin amp draw and thermistor probe data analog cable 5 J10 50 pin digital cable leftside Item Jumper No Function 6...

Page 44: ...mittent power failure tripping or the control panel keys do not function when the unit is powered The UVC3 UVC4 communicates with the control panel interface board through a USB Cable There are three sets of pins on the UVC3 board and four sets of pins on the UVC4 board Refer to the following chart to identify their function Note Use Part No 040084 001 Connector Programing Shunt to jumper pins Sta...

Page 45: ...nstalled Figure 2 60 Boards installed at the factory have two cables connected to the UVC4 board Connected at J13 is the USB cable part number 069023 Important See UVC4 Electrostatic Discharge and Proper Handling Procedures on page 2 22 before handling a UVC4 board ...

Page 46: ... 61 The UVC4 board is interchangeable with the UVC3 board When replacing a UVC3 board in the field adapter cables are needed Cable part number 069024 1 connects to the existing USB cable Important See UVC4 Electrostatic Discharge and Proper Handling Procedures on page 2 22 before handling a UVC4 board ...

Page 47: ... the Cover Control Box 7 Install a jumper on the W2 on the left side interface board 8 Reconnect power to the machine and turn power on Verify that the display says UNIT CLEANED 9 Remove the jumper from W2 on the left side interface board 10 Enter the Service Menu and go to the option Reset to Defaults 11 Perform a Reset to Defaults by selecting YES to clear all RAM memory 12 Install the USB flash...

Page 48: ...2 26 CONTROLS Models C712 C713 Controls 2 Refrigeration Schematic Figure 2 62 ...

Page 49: ...for barrel and hopper cooling in Auto Standby and the cooling phase of the heat mode Enabled in Auto and Standby Off in Wash and Off modes Output AXV Automatic expansion valve for the freezing cylinder 046365 Controls the refrigerant flow during the cooling of the freezing cylinder Filter Dryer Dryer Filter HP62 3 8 x 1 4S 048901 This keeps moisture dirt metal and chips from entering the refrigera...

Page 50: ...2 28 CONTROLS Models C712 C713 Controls 2 Notes ...

Page 51: ... Models C712 C713 Troubleshooting Troubleshooting General Troubleshooting Guide Electrical Troubleshooting Guide C712 C713 Electrical Troubleshooting Guide Pump Style Freezer Troubleshooting Bacteria Troubleshooting ...

Page 52: ...n the system d Purge and recharge the system e High overrun product C712 e Check pump operation forcorrect air mix ratio 3 Head pressure is too high a Condenser is dirty a Clean condenser b Water valve is out of adjustmentor is restricted b Check the adjustment and the water supply c Insufficient air space around machine c Make sure there is sufficient air space surrounding the machine see Specifi...

Page 53: ...e deflector b Bad scraper blades b Replace scraper blades c Dirty air cooled condenser c Clean monthly d Outdated mix d Use fresh mix e Refrigerant shortage e Locate leak and repair f Product viscosity set too warm f Adjust product viscosity g Incorrect usage of the mix feed tube C713 g Follow the correct feed tube procedures and use of the air orifice 12 Plugged door spout a Poor scraping a Repla...

Page 54: ...a Check the fault screen in the operator s menu b Insufficient air space b Allow 3 76 mm minimum clearance around all sides and install the deflector 21 When Auto is pressed freezer goes into Standby a Mix out condition a Add mix 22 Compressor On Too Long fault message a Inadequate pump operation C712 a Check the pump operation Assemble the pump according to instructions in the Operator Manual b T...

Page 55: ...NG 3 5 Models C712 C713 Troubleshooting 3 Electrical Troubleshooting Guide Modes of Operation Table 3 2 Components Standby Wash Auto Pump Compressor X X Beater Motor X X X Fan X X Air Mix Pump Motor X X Agitator X X ...

Page 56: ...upplied through pin 7 of the J6 terminal beater interlock relay and to the beater motor contactor coil Power Switch in the ON Position Mode Select PUMP With L1 power supplied to the L1 terminal of the interface board power is supplied through pin 5 of the J6 terminal to the air mix pump motor overload and then to the air mix pump motor Power Switch in the ON Position Mode Select Auto mode Power is...

Page 57: ... RESET button b Malfunctioning interface board b Replace interface board c Faulty pump motor c Replace motor d Faulty connection or draw switch d Check connections or replace switch 2 Excessive pump cylinder wear a Inadequate or incorrect lubrication of pump cylinder a Lubricate properly b Ball crank rotates clockwise b Rewire ball crank rotation to rotate counterclockwise 3 Not enough pressure in...

Page 58: ...be a source of contamination Table 3 4 Standard Plate Count SPC 50 000 Coliform 10 Cause Of Contamination Prevention 1 Human contamination a Wash hands and arms past elbows b Wear rubber gloves if cuts or skin conditions exist c Wash hands periodically throughout the day 2 Residue product deposits on mix contact surfaces milkstone buildup a Provide the proper brushes b Brush clean all parts and co...

Page 59: ... the tube g Parts components and brushes should be air dried overnight Never store the equipment in the storage cooler h Do not neglect daily cleaning practices wipe the external areas of the freezer periodically throughout the day remove the design caps and sanitize the area check the drip trays and splash shield 5 Mix stored improperly a Rotate stock to use older date code mix first Shelf life o...

Page 60: ...3 10 TROUBLESHOOTING Models C712 C713 Troubleshooting 3 Notes ...

Page 61: ...SP Model C712 C713 Bristol Box A Cap Relay X81081 27 Model C713 Copeland Pump A Mix Simplified X57029 Model C712 Door and Beater Assembly Model C712 Door and Beater Assembly Model C713 Plate A Dec Model C712 Plate A Dec Model C713 Rail Syrup X63883 27 Optional Switch A Dual Lever X69838 Model C712 C713 Actuator A Draw Switch X69835 Model C712 C713 Blower A X53725 27 Model C712 C713 Condenser A X68...

Page 62: ...aused by neglect or abuse Note See your authorized Taylor distributor for possible labor warranty Class 103 Parts The warranty for new equipment parts is one year from the original date of unit installation with a replacement parts warranty of three months Class 212 Parts The warranty for new equipment parts is two years from the original date of unit installation with a replacement parts warranty...

Page 63: ...9 72 68 66 75 70 73 67 74 6 7 9 8 5 4 3 2 1c 1b 1 1d 65 64 28 42 27 41 43 46 19 15 45 44 57 63 1a 61 60 59 31 32 33 62 24 23 22 21 20 19 18 17 16 15 14 12 11 10 58 56 36 55 54 53 52 48 47 26 39 25 40 27 28 41 38 29 30 34 35 12 19 30 37 29 42 46 19 15 45 44 71 43 49 50 51 13 ...

Page 64: ...6 25 Caster 4 SWV 3 4 10 STM 044106 26 Caster 4 SWV w Brake 046437 27 Dryer Filter HP62 3 8 048901 28 Valve Solenoid 7 64ORF 043449 27 29 Screw 10X3 8 Slotted 015582 Item Description Part No 30 Shroud Front Rear 059884 31 Guide A Drip Pan Left X59910 32 Control A See Pg 4 13 X67560 27 33 Cover Control Box 067984 34 Condenser AC Left 055813 1 Condenser AC Right 055813 2 35 Guide A Filter Right X599...

Page 65: ...Hopper 043934 65 Pump A Mix Simplified S S X57029 14 See Pg 4 19 66 Spacer Mix Probe 056985 Item Description Part No 67 Spacer Probe Mix Mid 056907 68 Probe Mix Out 056908 69 Probe A Mix X56912 70 Spacer Probe Mix Upper 056910 71 Sleeve Mounting Comp 039924 72 Screw 10 32X2 1 4 Slot 057610 73 O ring 1 3 8 OD X 070W 017395 74 Nut 10 32 Hex Screw 005598 75 Nut 1 4 20 Finished Hex 000707 Item Descrip...

Page 66: ...4 6 PARTS Models C712 C713 Parts 4 Operator Parts Model C712 Figure 4 2 1 2 3 4 25 27 26 28 5 6 22 6 8 7 9 10 11 12 23 24 13 14 16 15 18 19 17 20 21 ...

Page 67: ...11 11 Panel A Filter Louvered X59928 12 Caster 4 SWV 3 4 10 STM 044106 13 Screw 1 4 20 X 3 8 RHM 011694 14 Panel Corner Front R 063087 15 Deflector Blower EXH 047912 Item Description Part No 16 Caster 4 SWV 3 4 10 Stem w Brake 046437 17 Panel A Front Lower X59854 SER 18 Shield Splash Wire 19 3 4 L 033813 19 Tray Drip 19 5 8 L X 4 7 8 033812 20 Pan Drip 19 1 2 Long 035034 21 Panel Corner FRNT L 063...

Page 68: ...gure 4 3 7 6 5 3 2 1c 1b 4 1d 64 69 66 63 72 65 70 67 71 8 28 43 27 62 45 42 9 1a 1 32 33 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 39 31 61 60 59 58 57 56 36 55 54 52 53 44 40 41 25 27 38 28 62 26 29 30 34 35 29 37 30 19 12 43 42 19 15 47 45 68 46 50 49 51 48 ...

Page 69: ... 3 4 10 Stem w Brake 046437 27 Dryer Filter HP62 3 8 048901 28 Valve Solenoid 7 64ORF 043449 27 29 Screw 10X3 8 Slotted Hex 015582 Item Description Part No 30 Shroud Front Rear 059884 31 Guide A Drip Pan Left X59910 32 Control A See Pg 4 15 X67561 27 33 Cover Control Box 067984 SP1 34 Condenser AC Left 055813 1 Condenser AC Right 055813 2 35 Guide A Filter Right X59930 36 Panel A Front X63879 37 B...

Page 70: ...1 4S X1 4 046365 63 Spacer Mix Probe 056985 64 Probe A Mix X56912 65 Spacer Probe Mix Upper 056910 Item Description Part No 66 Probe Mix Out 056908 67 Spacer Probe Mix Middle 056907 68 Sleeve Mounting Comp 039924 69 Screw 10 32X2 1 4 Slot 057610 70 O ring 1 3 8 OD X 070W 017395 71 Nut 10 32 Hex Screw 005598 72 Nut 1 4 20 Finished Hex 000707 Item Description Part No ...

Page 71: ...PARTS 4 11 Models C712 C713 Parts 4 Operator Parts Model C713 Figure 4 4 1 2 3 4 5 6 7 8 10 9 11 12 13 26 25 18 17 16 15 14 19 20 21 22 23 8 24 ...

Page 72: ... Panel A Front X59836 11 Stud Nose Cone 055987 12 Filter Air Poly Flo 052779 11 13 Panel A Filter Louvered X59928 Item Description Part No 14 Caster 4 SWV 3 4 10 STM 044106 15 Screw 1 4 20 X 3 8 RHM 011694 16 Panel Corner Frnt R 063087 17 Caster 4 SWV w Brake 046437 18 Deflector Blower 047912 19 Shield Splash Wire 19 3 4 L 033813 20 Panel A Front Lower X59854 SER 21 Tray Drip 19 5 8 L X 4 7 8 0338...

Page 73: ... 4 13 Models C712 C713 Parts 4 Control A X67560 27 Model C712 Figure 4 5 13 14 15 8 16 8 18 16a 17 8 20 21 23 22 16a 16 8 15 14 24 8 9 8 25 8 11 8 26 1a 2 1 3 2 1 1a 4 5 6 7 2 8 9 21 10 8 11 8 12 8 8 12 8 19 ...

Page 74: ...R 039725 27 10 Trans 120 208 240V 051660 11 Block Terminal 1P 073423 12 Capacitor Start 47 56UF 037251 34 13 Bushing Snap 1 5 8ID x 2 OD 043637 14 Relay DPDT 100UA 7A 1 8HP 052111 03 Item Description Part No 15 Screw 6x5 16 SLTD Round 013646 16 Starter 1 Phase 6 3 to 10A 066794 27K 16a Overload Thermal 1P 067461 1K 17 Screw 10 32x5 8 UN SL HWH 039382 18 Relay 3 POLE 20A 208 240 066795 33 19 Bushin...

Page 75: ...PARTS 4 15 Models C712 C713 Parts 4 Control A X67561 27 Model C713 Figure 4 6 2 1 1a 4 2 5 6 7 8 9 10 8 11 8 12 2 1 3 1a 22 11 8 21 8 20 15 14 13 17 8 19 8 9 18 8 16a 16 8 15 14 13 ...

Page 76: ...40 7 Cable Ribbon 20C 16 L 040040 049 8 Screw 8X1 4 SLTD Hex 009894 9 Bushing Snap 15 16 ID 023396 10 Trans 120 208 240V 051660 11 Block Terminal 1P 073423 Item Description Part No 12 Bushing Snap 1 5 8ID X 2 OD 043637 13 Harness Wire Cntrl Box 068007 14 Screw 6X5 16 SLTD Round 013646 15 Relay DPDT 100UA 7A 1 8HP 052111 03 16 Starter 1 Phase 6 3 to 10A 066794 27K 16a Overload Thermal 1P 067461 1K ...

Page 77: ... Start 189 227UF 033044 1 2 Capacitor Run 25UF 440V 037431 3 Strap Capacitor 7 11 32 037890 4 Screw 10x3 8 Slotted Hex 015582 5 Harness Wire 06543627SP 6 Relay Start Compressor 062363 Item Description Part No 7 Screw 8x1 4 SLTD Hex 009894 8 Lug Grounding 017667 9 Screw 10 32x3 8 UNSL 039381 10 Block Terminal 2P L1 L2 039422 11 Screw 8x1 1 4 PHLP HD RD B 039420 ...

Page 78: ... No 1 Capacitor Start 189 22UF 033044 1 2 Plug Hole 1 093 1 125 DIA 049187 3 Capacitor Run 40MF 440V 036049 4 Screw 8x1 1 4 PHLP HD RD B 039420 5 Block Terminal 2P L1 L2 039422 Item Description Part No 6 Screw 8x1 4 SLTD Hex 009894 7 Relay Start Compressor 052401 27 8 Lug Grounding 4 14GA 017667 9 Screw 10 32x3 8 UNSL HWH 039381 Harness Wire 06543627SP ...

Page 79: ...der Pump Hopper 057943 2 Pin Retaining X55450 3 Piston Pump Simplified 053526 4 O ring 2 1 8 OD x 139W 225 020051 5 Cap Valve Body SS 056874 14 6 Gasket Simplified Pump Valve 053527 7 Adaptor Mix Inlet SS Red 054825 8 O ring 11 16ODX 103W Red 016132 9 Pin Cotter Hairpin 1 8DIA 044731 10 Shaft A Drive Mix Pump Hopper X41947 10a Crank Drive Hopper Mix Pump 039235 Item Description Part No 10b Shaft D...

Page 80: ...921 SER 5a Baffle A Long 4 IN X50882 6 Pin Handle Twin 059894 7 Gasket Door HT 4 Double 048926 8 O ring 7 8 OD X 103W SIL 083693 9 Valve A Draw X69615 10 Valve A Draw Center X62218 Item Description Part No 11 Seal Draw Valve 034698 12 Kit A Beater Front Shoes Bearing X50350 13 Beater A 3 4QT 1 Pin X46231 14 Blade Scraper Plastic 084350 15 Shaft Beater 032564 16 Seal Drive Shaft 032560 17 O ring 1 ...

Page 81: ...W 50 to Bag 024278 6 Nut Stud Black 3 250 Long 058765 7 Nut Stud Black 2 563 Long 058764 8 Door A 3SPT LG BAF W PRG X59921 SER 8a Baffle A Long 4 IN w Rad X50882 9 Valve A Draw X69615 Item Description Part No 10 Valve A Draw Center X62218 11 Cap Design 1 010 ID 6 PNT 014218 12 Seal Draw Valve 034698 13 O ring 7 8 OD x 103W SIL 083693 14 Pin Handle Twin 059894 15 Gasket Door HT 4 Double 048926 16 B...

Page 82: ...Dec Model C712 Figure 4 12 5 1 2 3 4 Item Description Part No 1 Plate Dec Syrup Rail 062121 2 Control ROHS INTF 063925 SER 3 Insulator PCB Interface 057168 Item Description Part No 4 Screw 6 32X3 8 BIN HD Slot 002201 5 Cable Ribbon 14C 3 L 056864 ...

Page 83: ...Dec Model C713 Figure 4 13 5 1 2 3 4 Item Description Part No 1 Plate DEC Syrup Rail 062122 2 Control ROHS INTF 063925 SER 3 Insulator PCB Interface 057168 Item Description Part No 4 Screw 6 32x3 8 BIN HD Slot 002201 5 Cable Ribbon 14C 3 L 056864 ...

Page 84: ...Nylon 034534 4 Box Heater 043954 5 Nut 10 32 Hex 005598 6 Washer 10 Ext Tooth Loc 002681 7 Nut 8 32 Hex M S Nut Small 000969 8 Washer 8 Ext Tooth Lock 000964 Item Description Part No 9 Thermostat Adj Snap 049993 10 Washer Flat 203 x 437 x 0 080963 11 Washer 3 16 USS Flat 18 8 005194 12 O ring 9 16 OD x 103W 016369 13 Thermostat HI Limit Snap 049992 14 Heater Strip 175W 240V 042782 15 Relief Strain...

Page 85: ... C713 Parts 4 Switch A Dual Lever X69838 Model C712 C713 Figure 4 15 1 3 2 Item Description Part No 1 Switch Lever SPDT 10A 125 028889 2 Washer 6 SAE Flat 18 8 SS 023546 Item Description Part No 3 Actuator Tandem Leaf 062408 ...

Page 86: ...Spring Return Left 038923 2 Bracket A Spring Return X69481 3 Spring Return Right 038924 4 Pin Pivot Draw Switch 038484 5 Bracket A Switch X69836 6 E ring 1 4 Black PHOS 032190 Item Description Part No 7 Arm Draw Switch Left 069166 8 Arm Draw Switch Right 069167 9 Rod Spring Retainer 038254 SP 10 Spring Extension 467x 062 069392 11 Screw Adjustment 069374 ...

Page 87: ...A X53725 27 Model C712 C713 Figure 4 17 4 3 2 1 Item Description Part No 1 Motor Fan 208 230V 50 60 HZ 053481 27 2 Bracket Capacitor 1 1 4X2 1 16 031205 Item Description Part No 3 Boot Capacitorinsulating 031314 4 Capacitor Run 7 5UF 370V 034749 ...

Page 88: ... Part No Motor A Condenser Fan Gnd Includes Items 1 8 X68008 27G 1 Condenser AC 7X6X1 25 027155 2 Kit A Motor Fan X62253 27 3 Harness Wire Danfoss 068006 G Item Description Part No 4 Shroud Danfoss 027386 5 Screw 10 32X3 8 UNSL 039381 6 Screw 8X1 4 SLTD Hex 009894 7 Screw 10 32X3 8 Slotted 006749 8 Nutsert 10 32 021106 ...

Page 89: ...ers order Stera Sheen part no 055492 100 packs or Kay 5 part no 041082 125 packs Not Shown 1 4 2 3 5 Item Description Part No 1 Pail 10 QT 013163 2 Tool O ring Removal 048260 WHT 3 Tool Mix Pump Shaft Removal 057167 Item Description Part No 4 Lubricant Taylor 4 oz 047518 5 Sanitizer Stera Sheen SEE NOTE Kit A Tune Up C712 X49463 81 ...

Page 90: ... 2 3 Item Description Part No 1 Brush Rear BRG 1 D x 2 LG 013071 2 Brush Dbl End Pump Feed Tube 013072 3 Brush Draw Valve 1 OD x 2 x1 014753 4 Brush Mix Pump Body 3 x 7 023316 Item Description Part No 5 Brush End Door Spout SS 039719 6 Brush Set LVB 050103 7 Brush Pump Spout 054068 ...

Page 91: ...Section 5 5 1 Models C712 C713 Parts List Parts List C71227F000 C71327F000 50HZ 60HZ w High V 50HZ ...

Page 92: ...stment Draw Paddle 069374 2 2 000 Spring Extension 467x 062x1 069392 2 2 103 Spring Return Left Twin TWIS 038923 1 1 103 Spring Return Right Twin TWI 038924 1 1 103 Actuator A Draw Switch X62401 1 1 103 Arm Switch Draw l 038649 1 1 103 Arm Switch Draw r 038650 1 1 103 Bracket A Spring Return X38257 1 1 103 E ring 1 4 032190 4 4 000 Pin Pivot Draw Switch 038484 1 1 103 Rod Spring Retainer 038254 1 ...

Page 93: ...F 370V 034749 1 1 103 Boot Capacitor Insulating 031314 1 1 000 Motor Fan 208 230V 50 60 HZ 053481 27 1 1 103 Boot Valve Expansion 050900 2 2 000 Brush Dbl End Pump Feed Tube 013072 1 1 000 Brush Draw Valve 1 OD X 2 X17 013073 1 1 000 Brush End Door Spout SS HT 039719 1 1 000 Brush Mix Pump Body 3 X 7 WH 023316 1 1 000 Brush Pump Spout MC13 054068 1 1 000 Brush Rear BRG 1 D X 2 LG X 14 013071 1 1 0...

Page 94: ...up Capacitor Run 25UF 440V 037431 2 2 103 Capacitor Start 189 227UF 33 033044 1 2 2 103 Relay Start Compressor 062363 2 2 103 Compressor L63A113DBLA 048259 33 2 2 512 Bristol 208 230V 60HZ 3PH Compressor TL3G R134A 047701 27 1 1 512 Relay Start Compressor TL3G 047702 27 1 1 103 Capacitor Start 60UF 220 275V 047703 1 1 103 Kit Mounting Compressor 047704 1 1 000 Condenser AC 7X6X1 25 2 ROW 027155 1 ...

Page 95: ... Exhaust 047912 1 1 103 Diagram Wiring C712 059898 27 1 000 208 230V 60HZ 1PH Diagram Wiring C712 059898 33 1 000 208 230V 60HZ 3PH 3 Wire Diagram Wiring C713 059899 27 1 000 Diagram Wiring C713 059899 33 1 000 Door A 3SPT LG BAF W PRG C712 X59921 SER 1 2 103 Baffle A Long 4 IN W RAD THD X50882 2 4 103 Bearing Front Shoe Kit X50350 2 000 Bearing Front 050216 4 000 Decal Door 3 Spout Twin Twist 062...

Page 96: ...000 Fastener Door Latch 030787 2 2 000 Fastener Door Strike 030788 2 2 000 Filter Corcom 6EH1 040140 001 1 1 103 Filter Air Poly Flo 052779 11 2 2 000 Gear A Reducer 4 21 1 021286 SER 2 2 212 Guard Power Switch 034830 1 1 103 Guide A Drip Pan Center X59913 1 1 103 Guide A Drip Pan Left X59910 1 1 103 Guide A Drip Pan Right X59911 1 1 103 Harness Wire C712 C717 CR 06543627SP 1 1 103 208 230V 60HZ 1...

Page 97: ... 062253 27 Kit A Probe Thermistor IP68 X82397 SER 4 4 103 Replaces 038061 BLK Kit A Tune C712 SIMPL Pump X49463 81 1 000 Gasket Door HT 4 Double 048926 2 000 Kit A Beater Front Shoes X50350 2 000 Kit A Draw Valve C712 X56200 17 1 000 Cap Design 1 010 ID 6 Point 014218 3 000 O ring 7 8 OD X 103W SIL 083693 5 000 S N M1103791 and up replaced 014402 and 019330 O ring 1 2OD X 070W 024278 4 000 Seal Dr...

Page 98: ...laced 014402 and 019330 Seal Draw Valve 034698 1 000 Seal Drive Shaft 032560 2 000 Tool O ring Removal Freezer 048260 WHT 1 000 Kit Mounting Compressor 047704 1 1 000 Label 3PH MTR PROT 1PH C 025949 1 1 000 208 230V 60HZ 3PH 3 Wire Label CK MTR Rotate CW ENG SPN 020090 1 1 000 208 230V 60HZ 3PH 3 Wire Label Caution BTR STRT G3 039897 1 1 000 Label Caution GRD PERM ENG SP 032164 1 1 000 Label Door ...

Page 99: ... 230V 50 60 HZ 053481 27 1 1 103 Motor Reducer Service 036955 34S 2 212 Nut Stud Black 2 563 Long 058764 2 2 103 Nut Stud Black 3 250 Long 058765 2 2 103 Orifice 022465 100 2 2 103 O ring 3 8 OD X 070W 016137 2 2 000 Overload Thermal Remote PMP SS 067965 2 103 Clip Retainer Overload PMP MTR 068038 2 000 Pail Mix 10 QT 013163 1 1 000 Pan Drip 7 875 059737 2 103 Pan Drip 12 5 059736 2 2 103 Pan Drip...

Page 100: ...up Rail 062121 1 103 Plate DEC C713 Syrup Rail 062122 1 103 Probe A Mix X56912 2 2 103 Mix Low Spacer Probe Mix Upper C708 056910 2 2 000 Probe Mix Out C708 056908 2 2 000 Mix Out Spacer Probe Mix Middle C70 056907 2 2 000 Spacer Mix Probe C708 056985 2 2 000 Screw 10 32X2 1 4 Slot Round 057610 2 2 000 O ring 1 3 8 OD X 070W 017395 6 6 000 Nut 10 32 Hex Machine Screw 005598 4 4 000 Nut 1 4 20 Fini...

Page 101: ...US W 052111 052112 2 2 103 Relay MTR Start TI 4CR 1 625 039725 27 2 103 Relay Start Compressor TL3G 047702 27 1 1 103 Relay Start Compressor 062363 2 2 103 Sanitizer Stera Sheen Green 055492 1 1 000 Screw 10 24X1 2 Taptite Torx 002077 4 4 000 Screw 6 32X3 8 BIN HD Slot SS 002201 2 2 000 Screw 5 16 18X2 1 2 Hex Cap 002498 8 8 000 Screw 10 32X3 8 RHM ZP 002742 8 8 000 Screw 1 4 20X3 8 RHM STNLS 0116...

Page 102: ...7 4 103 Shield Splash Wire 19 3 4 L 033813 1 1 103 Shoe Front Helix Use X50350 Kit 000 Spring Comp 970X 115X2 00 025707 4 4 103 Starter 1 Phase 6 3 to 10 AMP 066794 27K 2 2 103 208 230V 60HZ 1PH Overload Thermal 1P 6 3 10A 067461 1K 2 2 103 208 230V 60HZ 1PH Starter 3 Phase 4 to 6 5 AMP 066794 33J 2 2 103 208 230V 60HZ 3PH 3 Wire Overload Thermal 3P 4 0 6 5A 067461 3J 2 2 103 208 230V 60HZ 3PH 3 W...

Page 103: ...63877 1 1 103 Nut 10 32 Nylon Insert Lock 600144 2 2 000 Screw 10 32X1 2 SLTD Truss 037734 2 2 000 Trim Corner Rear L 059896 1 1 103 Trim Corner Rear R 059897 1 1 103 Tube A Feed Left C712 C717 X59808 1 103 O ring 11 16ODX 103W Red 016132 4 000 Tube A Feed Right C712 C717 X59809 1 103 O ring 11 16ODX 103W Red 016132 4 000 Tube A Feed SS 5 32 Hole DIA X29429 2 2 103 C712 Feed Tube Optional O ring 6...

Page 104: ...1 1 103 Plate Condenser W C 062043 SP 1 1 103 Pipe TEE 3 8 Water Valve Blk 032953 1 1 103 Switch Pressure 350 PSI SOLD 048231 2 2 103 Valve Water 3 8 Reg Head Press 046686 2 2 103 50HZ 60HZ w High V 50HZ C71235F000 C71335F000 220 240V 50HZ 3PH C71337R974 200V 50HZ 3PH C71239FW00 C71339R000 200V 50 60HZ 3PH C71240FW00 C71340FW00 220 240V 50HZ 1PH C71258FW00 C71358FW00 380 415V 50HZ 3N 4WIRE C71260F...

Page 105: ...V 50HZ 3N 4WIRE 220 380V 60HZ 3PH 4WIRE Diagram Wiring C712 059898 35 1 000 220 240V 50HZ 3PH Diagram Wiring C712 059898 39 1 000 200V 50 60HZ 3PH Diagram Wiring C712 059898 40 1 000 220 240V 50HZ 1PH Diagram Wiring C712 059898 58 1 000 380 415V 50HZ 3N 4WIRE Diagram Wiring C712 059898 60 1 000 220 380V 60HZ 3PH 4 WIRE Diagram Wiring C713 059899 35 1 000 220 240V 50HZ 3PH Diagram Wiring C713 05989...

Page 106: ... SO 051356 2 2 103 220 240V 50HZ 3PH 220 240V 50HZ 1PH 380 415V 50HZ 3N 4WIRE 220 380V 60HZ 3PH 4WIRE Motor 1 5 HP 021522 33 2 212 200V 50 60HZ 3PH Motor 1 5 HP Caps 10 2 O clock 021522 34 2 2 212 220 240V 50HZ 1PH 220 380V 60HZ 3PH 4WIRE Motor 1 5 HP 021522 35 2 2 212 220 240V 50HZ 3PH 380 415V 50HZ 3N 4 WIRE Motor 2 0 HP 017650 33 2 2 212 220 380V 60HZ 3PH 4 WIRE Panel A Upper Front C712 X63978 ...

Page 107: ... 103 Spinner A Panel w Filter X50276 27 103 Kit A Hopper Lock Twin X59106 103 Kit A Lock Draw Valve TW X62504 SER 103 Tray Parts Barrel 3 4 QT 067431 000 Tray Parts Pump Simplifie 056525 000 Adaptor Spout Hose Drain 063018 103 C71233F836 M C712 DQ Diagram Wiring C712 DQ 05989833DQ 1 000 Door A LG BAF W PRG C712 DQ X59921SER1 1 103 Baffle A Long 4 IN W RAD TH X50882 2 103 Bearing Front Shoe 050348 ...

Page 108: ...Hex SS 038623 6 103 Screw 4 40X1 SLTD Round 028890 2 000 Screw 4 40X5 8 SLTD Round 027219 4 000 Spring Return L 023487 3 103 Switch Lever SPDT 11A 125 27 039252 4 103 Adjustable Feed Tube A Feed Inner Air MI X67103 2 103 Tube A Feed Outer HT X67104 2 103 O ring 291 ID X 080W 018550 6 000 O ring 643 OD X 077W 018572 4 000 Kit A Tune Up 3 SPT C713 X49463 80A 1 000 C713 Hopper Agitator Blade A Agitat...

Page 109: ...Socket Set 006812 4 2 000 Shell A Insulated C712 X65598 1 512 Shell A Insulated C713 X65599 1 512 Tube A Feed SS 7 32 Hole X29429 4 2 2 103 Added as of M3071813 Integrated Syrup Rail Jar Syrup Plastic Shallow 036573 2 2 103 Jar Syrup Stainless Shall 036574 2 2 103 Ladle 1 OZ 120D Bend IN H 033637 1 2 2 103 Lid Syrup Jar 042706 2 2 103 Panel A Front Syr Rail X63884 27 1 1 103 Pump A Syrup Heated Br...

Page 110: ...ist Available Separately 5 PCB A LED 4 Position X63930 SER 1 212 Standoff Nylon 6 32X1 2L SNA 040280 002 2 000 Trim A Rear Corner L X81329 1 103 Harness Rear Mix Lights 081703 1 103 Description Part Number C712 Qty C713 Qty Warr Class Remarks ...

Page 111: ...712 C713 Wiring Diagrams Wiring Diagrams Diagram 059898 27 C712 Diagram 059898 33 C712 Diagram 059898 40 C712 Diagram 059898 58 C712 Diagram 059899 27 C713 Diagram 059899 33 C713 Diagram 059899 40 C713 Diagram 059899 58 C713 ...

Page 112: ...WHT BLU BLU BLK BLU WHT BLU WHT J2 J1 BLK T3 L3 I3 I4 L3 T3 BLK BLK L3 BLK BEATER MOTOR STARTER BLK T3 L3 I3 I4 L3 T3 BLK L3 BLK BLK BLK BLK FIGURE 1 L1 L2 WINDING PROTECTOR INTERNAL MAIN WINDING START WINDING START RELAY 047702 27 START CAPACITOR 047703 COMPRESSOR WIRING MODEL TL3G W HST 11 10 13 12 14 WHT LEFT SYRUP HEATER WHT RED RIGHT SYRUP HEATER RED BLK WHT OPTIONAL OPTIONAL AIR COOLED CONDE...

Page 113: ...WHT BLU BLU BLK BLU WHT BLU WHT J2 J1 BLK T3 L3 I3 I4 L3 T3 BLK BLK L3 BLK BEATER MOTOR STARTER BLK T3 L3 I3 I4 L3 T3 BLK L3 BLK BLK BLK BLK FIGURE 1 L1 L2 WINDING PROTECTOR INTERNAL MAIN WINDING START WINDING START RELAY 047702 27 START CAPACITOR 047703 COMPRESSOR WIRING MODEL TL3G W HST 11 10 13 12 14 WHT LEFT SYRUP HEATER WHT RED RIGHT SYRUP HEATER RED BLK WHT OPTIONAL OPTIONAL AIR COOLED CONDE...

Page 114: ...R MIX LEVEL LIGHTS IN 2 1 4 3 6 5 8 7 10 9 OUT 2 1 4 3 6 5 8 7 10 9 J19 1 2 J20 J19 1 2 J20 CABLE CABLE CABLE CABLE Model C712 059898 40 09 14 2014 Taylor Company EXTERNAL GROUND N L1 TERMINAL BLOCK BLK WHT INTERFACE BOARD POWER TRANSFORMER BLK ORN RED BLU 16V L2 EMI FILTER LOAD 1 L E N I L L1 L2 240V WHT NOT CONNECTED WHT WHT GRN YEL GRN YEL BLK GRN YEL BLK WHT POWER SWITCH 3PDT BLK ON OFF RED BL...

Page 115: ...N YEL BLK BLK WHT BLK BLK BLK BLK BEATER MOTOR STARTER BLK T3 L3 L3 T3 BLK L3 L2 BLK BLK WHT BLK BLK BLK BLK BLK BLK L2L3 BLK T3 L3 L3 T3 BLK BLK BLK BLK BLK BLK BLK BLK BLK BLK GRN YEL GRN YEL GRN YEL FIGURE 1 L1 L2 WINDING PROTECTOR INTERNAL MAIN WINDING START WINDING START RELAY 047702 27 START CAPACITOR 047703 COMPRESSOR WIRING MODEL TL3G W HST 11 10 13 12 14 GRN YEL LEFT SYRUP HEATER WHT RED ...

Page 116: ... ON 1 YELLOW INTERNAL ON 6 BLUE INTERNAL BLUE 1 2 5 4 S R LINE RELAY START CAPACITOR C INTERNAL OVERLOAD RUN CAPACITOR SCHEMATIC WIRING DIAGRAM CSR 1 2 5 4 C S R LINE RELAY RUN CAP START CAP COMPRESSOR TERMINAL COVER ABOVE ELECTRICAL DIAGRAM SHOWS WIRING NECESSARY TO HOOK UP A COMPRESSOR USING A START AND RUN CAPACITOR CSR WITH A RELAY WHITE BROWN BLACK BROWN 052396 1 EQUIPMENT GROUND BLEED RESIST...

Page 117: ... BLK L3 BLK BLK BLK BLK FIGURE 1 L1 L2 WINDING PROTECTOR INTERNAL MAIN WINDING START WINDING START RELAY 047702 27 START CAPACITOR 047703 COMPRESSOR WIRING MODEL TL3G W HST 11 10 13 12 14 WHT LEFT SYRUP HEATER WHT RED RIGHT SYRUP HEATER RED BLK WHT OPTIONAL AIR COOLED CONDENSER FAN M BLK BLK WATER COOLED IF THE UNIT HAS THE INTEGRAL SYRUP OPTION 405 THEN THIS JUMPER SHOULD BE INSTALLED CLR BLK BLK...

Page 118: ... AVAILABLE BLACK BLUE BEATER MOTOR CONTACTOR A O SMITH BEATER MOTOR WIRING STEPS 1 REMOVE BROWN JUMPER FROM BETWEEN TERMINAL 1 TO TERMINAL 5 2 MOVE BLUE INTERNAL FROM MOTOR MAIN WINDING FROM TERMINAL 5 TO TERMINAL 1 NOTE FOR CCWLE BLUE INTERNAL ON 1 YELLOW INTERNAL ON 6 BLUE INTERNAL BLUE 1 2 5 4 S R LINE RELAY START CAPACITOR C INTERNAL OVERLOAD RUN CAPACITOR SCHEMATIC WIRING DIAGRAM CSR 1 2 5 4 ...

Page 119: ...K BLK WHT BLK WHT BLK WHT BLK L2 L3 BLK WHT BLK BLK BLK BLK BLK BLK FIGURE 1 L1 L2 WINDING PROTECTOR INTERNAL MAIN WINDING START WINDING START RELAY 047702 27 START CAPACITOR 047703 COMPRESSOR WIRING MODEL TL3G W HST 11 10 13 12 14 4 GRN YEL LEFT SYRUP HEATER WHT RED WHT RIGHT SYRUP HEATER RED BLK GRN YEL AIR COOLED G R N Y E L CONDENSER FAN M BLK BLK WATER COOLED G R N Y E L BEATER MOTOR LINE MUS...

Page 120: ...6 10 WIRING DIAGRAMS Models C712 C713 Wiring Diagrams 6 Notes ...