CONTROLS
2-7
Models C712/C713
Controls
2
displayed. If the actual probe environment exceeds
200 °F (93°C), the respective screen display location will
read OVER indicating the temperature is out of range.
Fault History
The FAULT HISTORY will display up to 100 faults that
have occurred. Page numbers are displayed in the upper
right corner. Page one contains the most recent fault.
Pressing the Up Arrow button cycles through the FAULT
HISTORY pages from most recent to oldest. Pressing the
Down Arrow button cycles from the oldest to the most
recent. The date and time of the event are displayed on
the second line. The third line displays the reason for the
fault.
Figure 2-26
Faults Occurring While in AUTO or STANDBY Mode
(L/R) HPR>41F (5C) AFTER 4 HR—
The mix
temperature in the hopper was above 41°F (5°C) for
more than 4 hours.
(L/R) BRL>41F (5C) AFTER 4 HR—
The mix
temperature in the freezing cylinder was above 41°F
(5°C) for more than 4 hours.
(L/R) HPR>41F (5C) AFTER PF—
The mix temperature
in the hopper was above 41°F (5°C) for more than 4
hours following a power failure.
(L/R) HPR>45F (7C) AFTER 1 HR—
The mix
temperature in the left or right hopper was above 45°F
(7°C) for more than 1 hour.
(L/R) BRL>45F (7C) AFTER 1 HR—
The mix
temperature in the left or right barrel was above 45°F
(7°C) for more than 1 hour.
(L/R) BRL>41F (5C) AFTER PF—
The mix temperature
in the freezing cylinder was above 41°F (5°C) for more
than 4 hours following a power failure.
(L/R) HPR>59F (15C)—
The mix temperature in the
hopper exceeded 59°F (15°C).
(L/R) BRL>59F (15C)—
The mix temperature in the
hopper exceeded 59°F (15°C).
(L/R) COMP ON TOO LONG—
The compressor run time
exceeded the 11 minute timer.
Note:
Refer to your local health codes regarding
temperature recommendations for procedures to follow if
these fault screens appear.
Lockout History
The LOCKOUT HISTORY screen displays a history of
the last 100 soft locks, hard locks, brush clean dates, or
aborted heat cycles. Page numbers are indicated in the
upper right corner. Page 1 always contains the most
recent failure.
v
Figure 2-27
The second line of the screen displays the date and time
a failure occurs. The third line indicates the reason for a
failure, or will indicate if a successful brush cleaning has
occurred. Some failures occur with multiple reasons.
When this occurs, a record will be generated for each
reason.
Use the arrow buttons to move forward or backward to
view each screen.
System Information
The SYSTEM INFORMATION is displayed on three
separate screens. The first screen contains the control
and software version installed in the machine.
Figure 2-28
Touch the SEL button to advance to the next system
information screen containing the software language
version.
Figure 2-29
Touch the SEL button to advance to the third system
information screen containing the model bill of material
FAULT HISTORY
1
00/00/00
00:00
REASON
> Exit
LOCKOUT HISTORY
1
00/00/00
00:00
REASON
> Exit
SOFTWARE VERSION
C712 / C713 UVC4
VERSION X X X
> Next
Language
V4.00 English
> Next
Summary of Contents for C712
Page 9: ...INTRODUCTION 1 5 Models C712 C713 Introduction 1 Figure 1 1 ...
Page 11: ...INTRODUCTION 1 7 Models C712 C713 Introduction 1 Figure 1 2 ...
Page 22: ...1 18 INTRODUCTION Models C712 C713 Introduction 1 Notes ...
Page 42: ...2 20 CONTROLS Models C712 C713 Controls 2 Control Overview UVC4 Figure 2 58 ...
Page 48: ...2 26 CONTROLS Models C712 C713 Controls 2 Refrigeration Schematic Figure 2 62 ...
Page 50: ...2 28 CONTROLS Models C712 C713 Controls 2 Notes ...
Page 60: ...3 10 TROUBLESHOOTING Models C712 C713 Troubleshooting 3 Notes ...
Page 120: ...6 10 WIRING DIAGRAMS Models C712 C713 Wiring Diagrams 6 Notes ...