2-8
CONTROLS
Models C712/C713
Controls
2
and machine serial number.
Figure 2-30
Pressing the SEL button again will return to the Menu
screen.
Current Conditions
This screen provides the viscosity readings for the
product when the unit is running, and the hopper and the
freezing cylinder temperatures for the unit.
Figure 2-31
Press the SEL or Menu button to return to the Menu
screen.
Net Service Pin
The NET SERVICE PIN screen allows the manager or
service technician to initialize a network connection for
networking kitchens.
Figure 2-32
Pressing the Up or Down Arrow button will move the
arrow to Yes or No. Pressing the SEL button with the
arrow next to No will return to the Menu screen. Pressing
the SEL button with the arrow next to Yes will connect to
the network if a gateway card is connected. If Yes is
selected, the unit will appear to hang until the memory is
cleared and the defaults are loaded. The display may
show the message COMMUNICATIONS FAILURE
during this time.
Service Menu
The Service Menu option allows authorized, service
technicians to access and modify critical operating
parameters for the machine. The access code for the
Service Menu is:
5 2 3 1
.
Service Menu Options
The Service Menu screen includes the following options
which are also displayed in the Manager's Menu.
(See page 2-3.)
EXIT FROM MENU
SERVINGS COUNTER
SET CLOCK
AUTO START TIME
STANDBY MODE
MIX LEVEL AUDIBLE
FAULT DESCRIPTION
FAULT HISTORY
LOCKOUT HISTORY
SYSTEM INFORMATION
CURRENT CONDITIONS
NET SERVICE PIN
The Service Menu screen also includes the following
options which can only be accessed through the Service
Menu:
TEMPERATURE SCALE
STANDBY TEMP
HOPPER TEMP
VISCOSITY SETTING
COMPRESSOR CYCLE TIME
COMPRESSOR ON DELAY
BEATER OFF DELAY
MIX PUMP OFF DELAY
EDIT UNIT ID
SELECT LANGUAGE
MANUAL CONTROL
SOFTWARE UPDATE
RESET TO DEFAULTS
Temperature Scale
This option allows the service technician to choose the
scale in which the machine will display all temperatures.
B.O.M. C71227C000
S/N
K0000000
> Next
VISC
0.0
0.0
HOPPER
41.0
41.0
BARREL
41.0
41.0
NET SERVICE PIN
ARE YOU SURE?
Yes
> No
Summary of Contents for C712
Page 9: ...INTRODUCTION 1 5 Models C712 C713 Introduction 1 Figure 1 1 ...
Page 11: ...INTRODUCTION 1 7 Models C712 C713 Introduction 1 Figure 1 2 ...
Page 22: ...1 18 INTRODUCTION Models C712 C713 Introduction 1 Notes ...
Page 42: ...2 20 CONTROLS Models C712 C713 Controls 2 Control Overview UVC4 Figure 2 58 ...
Page 48: ...2 26 CONTROLS Models C712 C713 Controls 2 Refrigeration Schematic Figure 2 62 ...
Page 50: ...2 28 CONTROLS Models C712 C713 Controls 2 Notes ...
Page 60: ...3 10 TROUBLESHOOTING Models C712 C713 Troubleshooting 3 Notes ...