2-6
CONTROLS
Models C712/C713
Controls
2
Figure 2-21
Enable the AUTO START TIME by selecting the Up
Arrow button to move the arrow to Enable. Press the SEL
button to advance to the next screen.
Figure 2-22
Program the AUTO START TIME by selecting the Up
Arrow button to move the arrow to Change. Press the
SEL button to advance to the next screen.
Figure 2-23
Use the arrow buttons to program the AUTO START
TIME by increasing or decreasing the hour setting above
the cursor. Touch the SEL button to advance the cursor
and program the minutes setting. Touch the SEL button
to return to the previous screen with the new time setting
displayed. Touch the SEL button to exit the screen and
return to the Manager's Menu.
Standby Mode
The STANDBY MODE option is used to manually place
the machine in the Standby mode during long, no-draw
periods. Press the Up Arrow button to place the arrow
next to the appropriate side. Press the SEL button to
place that side of the machine into Standby and return to
the main menu screen.
Figure 2-24
Mix Level Audible
The MIX LEVEL AUDIBLE option, when enabled, will
alert the operator with an audible tone when there is a
mix-low or mix-out condition. The following screen is
displayed upon selecting this option.
Figure 2-25
Disable the audible tone feature by pressing the Down
Arrow button to move the arrow to Disable. Touch the
SEL button to save the new setting and return to the
Manager's Menu. The control panel icons for Mix Low
and Mix Out will illuminate as the mix level drops in the
hopper, but the audible tone will be disabled.
Fault Description
The LCD is located on the front control panel. During
normal operation, the display is blank. The display is
used to show menu options and notifies the operator if a
fault is detected. On international models, the display will
indicate the temperature of the mix in the hopper. If a
fault does occur, it will appear on the display.
NO FAULT FOUND—
There was no fault found in the
freezer. Nothing will appear on the screen after this
variable message appears.
BEATER OVERLOAD—
Place the power switch in the
OFF position. Press the beater reset button firmly. Place
the power switch in the ON position and restart in AUTO.
HPCO COMPRESSOR—
Place the power switch in the
OFF position. Wait 5 minutes for the unit to cool. Place
the power switch in the ON position and restart in AUTO.
PRODUCT DOOR OFF—
The door must be installed on
the unit.
*HOPPER THERMISTOR FAIL—
Place the power switch
in the OFF position. Replace the hopper thermistor
probe.
*BARREL THERMISTOR FAIL—
Place the power switch
in the OFF position. Replace the barrel thermistor probe.
Note:
Three codes have been set up to assist in
diagnosing bad thermistor probes. If a probe has shorted
(resistance less than 1 ohm), SHRT will be displayed on
the screen for its respective unit location. If the probe is
open (resistance above 1 megohm), OPEN will be
AUTO START TIME
DISABLED
Enable
> Disable
AUTO START TIME
00:00
Change
> Exit
AUTO START TIME
00:00
STANDBY MODE
LEFT
RIGHT
> EXIT
MIX LEVEL AUDIBLE
ENABLED
> Enable
Disable
Summary of Contents for C712
Page 9: ...INTRODUCTION 1 5 Models C712 C713 Introduction 1 Figure 1 1 ...
Page 11: ...INTRODUCTION 1 7 Models C712 C713 Introduction 1 Figure 1 2 ...
Page 22: ...1 18 INTRODUCTION Models C712 C713 Introduction 1 Notes ...
Page 42: ...2 20 CONTROLS Models C712 C713 Controls 2 Control Overview UVC4 Figure 2 58 ...
Page 48: ...2 26 CONTROLS Models C712 C713 Controls 2 Refrigeration Schematic Figure 2 62 ...
Page 50: ...2 28 CONTROLS Models C712 C713 Controls 2 Notes ...
Page 60: ...3 10 TROUBLESHOOTING Models C712 C713 Troubleshooting 3 Notes ...
Page 120: ...6 10 WIRING DIAGRAMS Models C712 C713 Wiring Diagrams 6 Notes ...