CONTROLS
2-19
Models C712/C713
Controls
2
Jumper Pin Chart - UVC4
** Jumper initially installed at factory.
Table 2-4
** Jumper initially installed at factory.
Table 2-5
** Jumper initially installed at factory.
Table 2-6
Notes:
1. Left and right are determined while facing the front of
machine.
2. Specified feature is established when the jumper is
installed.
3. International mode (jumper removed) enables direct
use of Heat and Standby buttons and hopper
temperature display. Note: C712/C713 Standby
buttons are always enabled. C712/C713 do not have
Heat buttons.
4. Jumper should be installed on shake machines to
enable proximity sensor. It is not active on soft serve
machines; jumper can remain installed.
Feature
C712/C713
Left Interface
X59485-SER
C712/C713
Right Interface
X59485-SER
Force Brush Clean Status
W2
Syrup Heater Enable
W3
Open All Left Solenoids
W4
Open All Right Solenoids
W4
Clock/Calendar Override
W5
Force Glycol Pump On
59F Fault Detection Enable
W2**
Standby Stir Cycle Disable
W5
Reduced Mix Low Sensitivity
W6
W6
Reduced Mix Out Sensitivity
W7
W7
7C/45F 90 Min. Cool Phase
Unused
W1
W1
Unused
Disable Control Panel (Self Serve)
J10 - 7 & 8
UVC4 Control Feature
Jumper
>41F for 4 hours & >45 for 1 hr
JP1 - 1 & 2**
Reserved (do not install)
JP1 - 3 & 4
Domestic/International
(Note 3)
JP2 - 1 & 2 **
Reserved (do not install)
JP3 - 1 & 2
Reserved (do not install)
JP4 - 1 & 2
Proximity Sensor
(Note 4)
JP5 - 1 & 2**
Reserved (do not install)
JP6 - 1 & 2
Reserved (do not install)
JP7 - 1 & 2
Reserved (do not install)
RTCK - 1 & 2
Reserved (do not install)
DBGEN - 1 & 2
Personality Board
0–6 Beater Motor Amperage (do not use)
A
0–12 Beater Motor Amperage
B**
Summary of Contents for C712
Page 9: ...INTRODUCTION 1 5 Models C712 C713 Introduction 1 Figure 1 1 ...
Page 11: ...INTRODUCTION 1 7 Models C712 C713 Introduction 1 Figure 1 2 ...
Page 22: ...1 18 INTRODUCTION Models C712 C713 Introduction 1 Notes ...
Page 42: ...2 20 CONTROLS Models C712 C713 Controls 2 Control Overview UVC4 Figure 2 58 ...
Page 48: ...2 26 CONTROLS Models C712 C713 Controls 2 Refrigeration Schematic Figure 2 62 ...
Page 50: ...2 28 CONTROLS Models C712 C713 Controls 2 Notes ...
Page 60: ...3 10 TROUBLESHOOTING Models C712 C713 Troubleshooting 3 Notes ...