USER INTERFACE
5-13
Models C709 & C717
User Interface
5
Use the arrow keys to move to the desired operation and
press the SEL key to accept the selection.
Mix Level Audible
The MIX LEVEL AUDIBLE option, when enabled, will
alert the operator with an audible tone when there is Mix
Low or Mix Out condition. The following screen is
displayed upon selecting this option:
Disable the audible tone feature by pressing the Down
arrow key to move the arrow to “Disable.” Press the SEL
key to save the new setting and return to the Menu. The
control panel icons for Mix Low and Mix Out will
illuminate as the mix level drops in the hopper, but the
audible tone will be disabled.
Fault Description
The FAULT DESCRIPTION screen will indicate a fault
with the freezer and where the fault occurred. When no
faults are detected, the following screen will be
displayed:
Press the SEL key to display the next fault found, or
return to the Manager Menu if no other faults exist.
Pressing the SEL key anytime faults are displayed will
clear the faults, if corrected, upon returning to the
Manager Menu screen.
Listed below are the variable messages which will
appear, along with an explanation for the corrective
action.
NO FAULT FOUND—
There was no fault found in the
freezer. Nothing will appear on the screen after this
variable message appears.
BEATER OVERLOAD—
Place the power switch in the
OFF position. Wait 5 minutes for the machine to cool.
Press the beater RESET button firmly. Place the power
switch in the ON position and restart in Auto.
COMPRESSOR HPCO—
Place the power switch in the
OFF position. Wait 5 minutes for the machine to cool.
Place the power switch in the ON position and restart in
Auto.
HOPPER THERMISTOR FAIL*—
Place the power switch
in the OFF position. Call the service technician.
BARREL THERMISTOR FAIL*—
Place the power switch
in the OFF position. Call the service technician.
*Note:
Three codes have been set up to assist in
diagnosing bad thermistor probes. If a probe has shorted
(resistance less than 1 ohm), “SHRT” will display for its
respective machine location. If the probe is open
(resistance above 1 megohm), “OPEN” will display. If the
actual probe environment exceeds 200°F (93°C), the
respective screen display location will read “OVER,”
indicating the temperature is out of range.
COMP ON TOO LONG—
The compressor run time
exceeded the 11-minute timer.
Fault History
The FAULT HISTORY will display up to 100 faults that
have occurred. The most recent fault is displayed on
screen 1. The date, time, and fault description is
displayed on each screen.
AGITATOR OPERATION
> Standard operation
with Hopper Refrig
Exit
MIX LEVEL AUDIBLE
ENABLED
> Enable
Disable
FAULT DESCRIPTION
NO FAULT FOUND
FAULT HISTORY
1
00/00/00
00:00
REASON
> Exit
Summary of Contents for C709
Page 8: ...1 4 TO THE INSTALLER Models C709 C717 To the Installer 1 Notes...
Page 22: ...4 10 OPERATOR PARTS IDENTIFICATION Models C709 C717 Operator Parts Identification 4 Notes...
Page 58: ...8 4 TROUBLESHOOTING GUIDE Models C709 C717 Troubleshooting Guide 8 Notes...
Page 60: ...9 2 PARTS REPLACEMENT SCHEDULE Models C709 C717 Parts Replacement Schedule 9 Notes...
Page 64: ...10 4 LIMITED WARRANTY ON EQUIPMENT Models C709 C717 Limited Warranty on Equipment 10 Notes...
Page 68: ...11 4 LIMITED WARRANTY ON PARTS Models C709 C717 Limited Warranty on Parts 11 Notes...