USER INTERFACE
5-5
Models C709 & C717
User Interface
5
Power-Up Memory (Initializing)
The brush-clean counter should display “00” during the
initializing sequence.
When the machine is powered, the control system will
initialize to perform a system check. The screen will
display INITIALIZING. There are four types of data the
system will check: LANGUAGE, SYSTEM DATA,
CONFIG DATA, and LOCKOUT DATA.
Language Data Check
The UVC control supports multiple languages by storing
language records in battery-backed memory. After
power-up or a reset, a data check is performed to
validate language records are present and not corrupted.
If the check is successful, initialization continues.
Otherwise, the operator is prompted to select a
language. While the check is being performed, the
following screen is displayed:
Note:
If there is a language initialization fault, the
machine will prompt the operator to select a language
prior to beginning the initializing sequence. Once a
language has been selected, the machine will store the
language selection. If the machine is powered down, the
machine should not ask for a language selection again
unless another language initialization fault occurs.
English is the default language.
System Data Check
System data is protected separately from the rest of the
data in the machine’s memory. System data includes
settings that change frequently, such as the machine
mode (e.g., Auto, Wash), lockout status, serving
counters, and fault codes. While system data is being
checked, the following screen is displayed:
If the system data is corrupted, the machine is set to the
Off mode, the serving counters are set to zero, and the
faults are cleared. A “SYSTEM CRC ERR” fault is
displayed on the screen. The operator must push the
SEL key to acknowledge the fault.
Configuration Data Check
Configuration data is protected separately from the rest
of the data in the machine’s memory. Configuration data
is information programmed through the operator and
service menus. While configuration data is being
checked, the following screen is displayed:
If Configuration data is corrupted, all operator and
service settings are reset to factory defaults. A CONFIG
CRC ERR fault is displayed on the screen. The machine
will continue to operate in its previous mode, but with
factory default settings.
Lockout Data Check
Lockout data is protected separately from the rest of the
data in the machine’s memory. While the lockout data is
being checked, the following screen is displayed:
If lockout data is corrupted, all the lockout history is
cleared and a LOCKOUT CRC ERR fault is displayed on
the screen.
After the memory has been tested, the Safety Timeout
screen will be displayed.
Initializing
Language
Initializing
System Data
Initializing
Config Data
Initializing
Lockout Data
Summary of Contents for C709
Page 8: ...1 4 TO THE INSTALLER Models C709 C717 To the Installer 1 Notes...
Page 22: ...4 10 OPERATOR PARTS IDENTIFICATION Models C709 C717 Operator Parts Identification 4 Notes...
Page 58: ...8 4 TROUBLESHOOTING GUIDE Models C709 C717 Troubleshooting Guide 8 Notes...
Page 60: ...9 2 PARTS REPLACEMENT SCHEDULE Models C709 C717 Parts Replacement Schedule 9 Notes...
Page 64: ...10 4 LIMITED WARRANTY ON EQUIPMENT Models C709 C717 Limited Warranty on Equipment 10 Notes...
Page 68: ...11 4 LIMITED WARRANTY ON PARTS Models C709 C717 Limited Warranty on Parts 11 Notes...