TO THE INSTALLER
Models 358 and 359
To the Installer
1
Air-Cooled Machine
Do not
obstruct air intake and discharge openings:
Air-cooled machines require a minimum of 3 in. (76 mm)
of clearance around all sides of the freezers and
3-1/2 in. (89 mm) on the bottom.
Model 359 Only:
Installation of air deflector is required.
Failure to allow adequate clearance can reduce the
refrigeration capacity of the freezers and possibly cause
permanent damage to the compressors.
Electrical Connections
IMPORTANT!
In the United States, this
machine is intended to be installed in accordance with
the National Electrical Code (NEC), ANSI/NFPA 701987.
The purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
In all other areas of the world, the machine should be
installed in accordance with the existing local codes.
Please contact your local authorities if you have any
questions.
Each machine requires one power supply for each data
label on the machine. Check the data label(s) on the
machine for branch circuit overcurrent protection or fuse,
circuit ampacity, and other electrical specifications.
See the wiring diagram provided inside the electrical box
for proper power connections.
WARNING!
This machine must be properly
grounded. Failure to do so can result in severe personal
injury from electrical shock.
IMPORTANT!
An equipotential grounding lug is
provided with this machine. Some countries require the
grounding lug to be properly attached to the rear of the
frame by the authorized installer. The installation location
is marked by the equipotential bonding symbol (5021 of
IEC 60417-1) on both the removable panel and the
machine's frame.
IMPORTANT!
•
Stationary machines which are not equipped
with a power cord and a plug or another device
to disconnect the machine from the power
source must have an all-pole disconnecting
device with a contact gap of at least 0.125 in.
(3 mm) in the external installation.
•
Machines that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
GFI, installed by authorized personnel to local
codes.
•
Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
•
If the supply cord is damaged, it must be
replaced by a Taylor service technician to avoid
a hazard.
•
Secure supply cord ground lead to machine in a
location where if the cord is pulled the main
power leads become taut before the ground
lead can break loose.
FOLLOW YOUR LOCAL ELECTRICAL CODES.