8-2
TROUBLESHOOTING GUIDE
Models 358 and 359
Troubleshooting Guide
8
8. Excessive mix leakage
in the driveshaft drip
pan.
a. Missing or worn driveshaft seal on
driveshaft.
a. Install or replace regularly.
b. The driveshaft seal is installed
inside out.
b. Install the seal properly.
c. Lack of lubrication.
c. Lubricate properly.
d. Worn rear shell bearing.
d. Contact a Taylor service technician to
replace the rear shell bearing.
- -
9. Excessive mix leakage
from the door spout.
a. Missing or worn draw valve
O-rings.
a. Install or replace regularly.
b. Inadequate lubrication of draw
valve O-rings.
b. Lubricate properly.
c. Wrong type of lubricant is being
used (example: petroleum-based
lubricant).
c. Use proper lubricant (example: Taylor
Lube).
10.No freezer operation
after placing the
machine in Auto.
a. The machine is unplugged.
a. Plug into wall receptacle.
- -
b. There is no mix in the mix hopper.
b. Fill the mix hopper with mix.
c. Circuit breaker tripped to OFF or
blown fuse.
c. Turn breaker to ON position or
replace fuse.
- -
d. Beater motor out on reset.
d. Reset the freezer.
11.Product is not feeding
into the freezing
cylinder.
a. Inadequate level of mix in the mix
hopper.
a. Fill the mix hopper with mix.
b. Mix inlet hole frozen up.
b. Mix hopper temperature needs
adjustment. Contact a Taylor service
technician.
- -
Problem
Probable Cause
Remedy
Page
Ref.