APX-03 Keypad & Proximity Reader Wiring Details

Fig.3 - Wiring detail for Electric Lock with Current Draw 1amp or over

EG: Two Magnetic Locks including Exit Button and Call Point

N/C

COM

N/O

Com N/O

Exit Button

OK

OK

1

1

2

2

3

3

FUN

FUN

4

4

5

5

6

6

7

7

8

8

9

9

CLR

CLR

0

0

EN

MENU

MENU

F
U
S
E

N E L

O/P +
O/P -

Regulated 12v DC Power Supply

(Min 2amp Rated)

Fused Spur

Capacitor

474J 100JS

APX03 Keypad/Reader

Black - Negative input

Red - Positive input

Blue - Ground

White - RQE

Yellow - Relay 1 Common

Brown - Relay 1 Norm. Open

Green - Relay 1 Norm. Closed

Note: Violet, Orange and
Grey wires are not used

+

-

Magnetic Locks 12v DC

Com N/C

Emergency

Call Point

Volt-Free Relay

+

-

Note: Linking wiring from
one magnet to the other
will affect Holding force.

Note: This wiring method can also be

used for Shear Magnets or Solenoid Bolts

OK

OK

1

1

2

2

3

3

FUN

FUN

4

4

5

5

6

6

7

7

8

8

9

9

CLR

CLR

0

0

EN

MENU

MENU

+

-

12v DC

Bell / Sounder

(Max 100mA)

F
U
S
E

N E L

O/P +

O/P -

Regulated 12v DC Power Supply (Min 1amp)

Fused Spur

Fig.4 - Wiring detail for Connection of a 12v DC Bell or Sounder

Grey - Relay 2 Normally open

Orange - Relay 2 Common

Red - Positive Input

Black - Negative Input

Link Orange wire

to Red wire

3

Web: www.tatecolson.co.uk            E-mail:[email protected]                                           Tel: 01704-502801                  Fax: 01704-502810

Remember to link the

Yellow wire to the

Red wire

+

-

Summary of Contents for APX-03

Page 1: ...Fob and 4 Digit Group Code Mode 3 User Fob Group code Deleting a Single Fob Deleting a Group of Fobs Mode 2 3 Page 7 Restoring a Deleted Fob Changing Lock open Time Bell ringing time Changing the Mas...

Page 2: ...on Keypad must be fixed to a flat and level surface The recommended fixing height is 1 1 5 metres from the floor If fixing more than 1 keypad ensure there is a gap of at least 50cm 20 to avoid interfe...

Page 3: ...tail for Electric Release including Exit Button Link the Yellow wire to the Red wire Com N O Exit Button OK OK 1 1 2 2 3 3 FUN FUN 4 4 5 5 6 6 7 7 8 8 9 9 CLR CLR 0 0 EN MENU MENU F U S E N E L O P O...

Page 4: ...nge and Grey wires are not used Magnetic Locks 12v DC Com N C Emergency Call Point Volt Free Relay Note Linking wiring from one magnet to the other will affect Holding force Note This wiring method ca...

Page 5: ...of the Keypad as this will not allow the unit to be programmed correctly If the wrong information is entered the Error indicator will flash once along with a low tone bleep then the keypad will retur...

Page 6: ...Bleep and OK indicator flashes once To Add a Group of Fobs by Fob No Enter into Programming mode as shown on page 4 Example Indication 1 2 Enter Function code 31 then EN FUN 31 EN OK indicator flashe...

Page 7: ...ode entry Note To Delete a Group code follow the above programming but enter 0000 instead of the Group code When a Group code is deleted the Fobs will revert to Fob only Mode 2 operation Fob Code Oper...

Page 8: ...and Power indicator flashes 6 Exit Programming Mode FUN 2 EN Long Bleep and OK indicator flashes once To Change Lock open time Note The number of seconds must be entered as 3 digits I E 5 Seconds 005...

Page 9: ...r Adding a Master Fob when original Master Fob is Lost To Program a new Master Fob when the original has been lost you will need to remove the Front Cover of the Keypad and look for a label in the top...

Page 10: ...FIRST FOB No LAST FOB No GROUP 01 GROUP 11 GROUP 02 GROUP 12 GROUP 03 GROUP 13 GROUP 04 GROUP 14 GROUP 05 GROUP 15 GROUP 06 GROUP 16 GROUP 07 GROUP 17 GROUP 08 GROUP 18 GROUP 09 GROUP 19 GROUP 10 GROU...

Page 11: ...10 FOB No FOB No NAME FOB NUMBER NAME LIST CONT D NAME Photocopy this sheet if required...

Page 12: ...page 8 Lock does not open when I use my 4 Digit code Make sure you press CLR before the 4 Digit code and EN after the code Note The OK indicator should flash after CLR is pressed If the OK indicator...

Reviews: