APX-03 Keypad & Proximity Reader Programming Instructions

Additional Programming functions

Example

Indication

1

Enter into Programming mode as shown on page 4.

2 Enter Function code 48 then EN

FUN  48  EN

OK indicator flashes

3 Enter 0 then EN to clear data

0 EN

Bleep followed by several chirps

To Clear all Code & Fob data:

After a few seconds the keypad will go into the Initial Power up sequence so you will need to re-program the
Lowest Fob number as the Master Fob again (see Initial Power up). All Code & Fob data is now deleted.

8

CARD TYPE

EM

FREQUENCY

125KHz

MAXIMUM FOB READING RANGE

110mm

MAXIMUM NUMBER OF FOBS

12,000 (20 BATCHES OF 600 CONSECUTIVE No'S)

MAXIMUM NUMBER OF CODES

FIVE 4 DIGIT USER CODES

NUMBER OF DOORS

ONE

DIGITAL OUTPUTS

TWO VOLTAGE FREE RELAYS (Max 24v DC @ 1A)

INDICATION

3 LIGHTS (POWER / OK / ERROR)

BACKLIGHTING

ALL BUTTONS (GREEN)

HOUSING MATERIAL

PC + ABS

OPERATING TEMPERATURE

-20 deg C to 55 deg C

STORAGE TEMPERATURE

-25 deg C to 85 deg C

POWER REQUIREMENTS

12 Volts DC +/- 10% (Min 300mA)

LOCK SUPPRESSION DEVICE

CAPACITOR 474J 100JS

DIMENSIONS

Width 81mm x Height 123mm x Depth 21mm

SPECIFICATIONS:-

Instructions for Adding a Master Fob when original Master Fob is Lost

To Program a new Master Fob when the original has been lost you will need to remove the Front Cover of the
Keypad and look for a label in the top right corner showing an 8 digit number (if there is no label you will need to
remove the unit from the wall and look on the back for a label with a Barcode and 12 digit serial number).
Make a note of the 5th to 8th numbers (4 digits). Note: All other Code and Fob data will remain the same.

Indication

1

Power indicator will go out

2

All 3 indicators flash once then Power indicator
lights followed by a Long Bleep then Short Bleep.

3

OK indicator will start flashing

4

All 3 indicators will light up followed by 2 Long
Bleeps then a Short Bleep.

5

Long Bleep and OK indicator flashes once

Note: When adding a New Master Fob we recommend the next lowest number fob is used.

Enter the 4 digit number from the Keypad label then EN

When the Error & OK lights start flashing present the Fob you
want to add as a New Master Fob within 10 seconds.

To Add a New Master Fob when Original is Lost:

Switch the Power Off to the Keypad for 30 Seconds.

Switch Power on and wait for the Keypad to respond

Immediately after the Short Bleep enter MENU then EN

Web: www.tatecolson.co.uk            E-mail:[email protected]                                           Tel: 01704-502801                  Fax: 01704-502810

Summary of Contents for APX-03

Page 1: ...Fob and 4 Digit Group Code Mode 3 User Fob Group code Deleting a Single Fob Deleting a Group of Fobs Mode 2 3 Page 7 Restoring a Deleted Fob Changing Lock open Time Bell ringing time Changing the Mas...

Page 2: ...on Keypad must be fixed to a flat and level surface The recommended fixing height is 1 1 5 metres from the floor If fixing more than 1 keypad ensure there is a gap of at least 50cm 20 to avoid interfe...

Page 3: ...tail for Electric Release including Exit Button Link the Yellow wire to the Red wire Com N O Exit Button OK OK 1 1 2 2 3 3 FUN FUN 4 4 5 5 6 6 7 7 8 8 9 9 CLR CLR 0 0 EN MENU MENU F U S E N E L O P O...

Page 4: ...nge and Grey wires are not used Magnetic Locks 12v DC Com N C Emergency Call Point Volt Free Relay Note Linking wiring from one magnet to the other will affect Holding force Note This wiring method ca...

Page 5: ...of the Keypad as this will not allow the unit to be programmed correctly If the wrong information is entered the Error indicator will flash once along with a low tone bleep then the keypad will retur...

Page 6: ...Bleep and OK indicator flashes once To Add a Group of Fobs by Fob No Enter into Programming mode as shown on page 4 Example Indication 1 2 Enter Function code 31 then EN FUN 31 EN OK indicator flashe...

Page 7: ...ode entry Note To Delete a Group code follow the above programming but enter 0000 instead of the Group code When a Group code is deleted the Fobs will revert to Fob only Mode 2 operation Fob Code Oper...

Page 8: ...and Power indicator flashes 6 Exit Programming Mode FUN 2 EN Long Bleep and OK indicator flashes once To Change Lock open time Note The number of seconds must be entered as 3 digits I E 5 Seconds 005...

Page 9: ...r Adding a Master Fob when original Master Fob is Lost To Program a new Master Fob when the original has been lost you will need to remove the Front Cover of the Keypad and look for a label in the top...

Page 10: ...FIRST FOB No LAST FOB No GROUP 01 GROUP 11 GROUP 02 GROUP 12 GROUP 03 GROUP 13 GROUP 04 GROUP 14 GROUP 05 GROUP 15 GROUP 06 GROUP 16 GROUP 07 GROUP 17 GROUP 08 GROUP 18 GROUP 09 GROUP 19 GROUP 10 GROU...

Page 11: ...10 FOB No FOB No NAME FOB NUMBER NAME LIST CONT D NAME Photocopy this sheet if required...

Page 12: ...page 8 Lock does not open when I use my 4 Digit code Make sure you press CLR before the 4 Digit code and EN after the code Note The OK indicator should flash after CLR is pressed If the OK indicator...