APX-03 Keypad & Proximity Reader Wiring Details
Com N/O
Exit Button
OK
OK
1
1
2
2
3
3
FUN
FUN
4
4
5
5
6
6
7
7
8
8
9
9
CLR
CLR
0
0
EN
MENU
MENU
F
U
S
E
N E L
O/P +
O/P -
Regulated 12v DC Power Supply
(Min 1amp Rated)
Fused Spur
Electric Release
12v DC Fail Lock*
(Max 1amp load)
Capacitor
474J 100JS
APX03 Keypad/Reader
Black - Negative input
Red - Positive input
Blue - Ground
White - RQE
Yellow - Relay 1 Common
Brown - Relay 1 Norm. Open
Green - Relay 1 Norm. Closed*
*For Fail Unlock
version use Green
wire instead
Note: Violet, Orange and
Grey wires are not used
Fig.1 - Wiring detail for Electric Release including Exit Button
Link the Yellow wire
to the Red wire
Com N/O
Exit Button
OK
OK
1
1
2
2
3
3
FUN
FUN
4
4
5
5
6
6
7
7
8
8
9
9
CLR
CLR
0
0
EN
MENU
MENU
F
U
S
E
N E L
O/P +
O/P -
Regulated 12v DC Power Supply
(Min 1amp Rated)
Fused Spur
Capacitor
474J 100JS
APX03 Keypad/Reader
Black - Negative input
Red - Positive input
Blue - Ground
White - RQE
Yellow - Relay 1 Common
Brown - Relay 1 Norm. Open
Green - Relay 1 Norm. Closed
Note: Violet, Orange and
Grey wires are not used
+
-
Magnetic Lock 12v DC
Maximum 1amp load
Com N/C
Emergency
Call Point
Fig.2 - Wiring detail for Magnetic Lock including Exit Button and Call Point
Link the Yellow wire
to the Red wire
2
Web: www.tatecolson.co.uk E-mail:[email protected] Tel: 01704-502801 Fax: 01704-502810