MODE 3 - User Fob + 4 Digit Group code

Mode 3 provides more security by allocating a group of user Fobs with a common 4 digit code which has to be
entered after the Fob is recognised by the Keypad.  When adding the batch of Fobs they must be programmed
into a different group from those being used for Fob only access (Mode 2).
You must Program the Fobs first before programming the Common Group code.

First Program the batch of Fobs as per Mode 2 but use a different Group number (see page 5)

Example

Indication

1

2 Enter Function code 45 then EN

FUN  45  EN

OK indicator flashes

3 Enter Fobs Group No (01 to 20) then EN

01  EN

OK indicator flashes

4 Enter New 4 Digit Group code then EN

5678  EN

OK indicator flashes

5 Re-Enter New 4 Digit Code then EN

5678  EN

Long Bleep and OK indicator flashes

6 Exit Programming Mode:

FUN  2  EN

Long Bleep and OK indicator flashes

Important Note: The Group Code will now have to be entered after the Fob is presented.

Enter into Programming mode as shown on page 4.

To Add a 4 Digit Group Code for
Fob+Code entry:

Note: To Delete a Group code follow the above programming but enter "0000" instead of the Group code.
When a  Group code is deleted the Fobs will revert to Fob only (Mode 2) operation.

Fob+Code Operation

: Hold the fob in front of the buttons within 7cm, keypad will bleep and OK will start to flash.

Enter the 4 digit Group code then EN. If Accepted OK will flash.   If code is Rejected you will hear a long Bleep
and Error will flash. Re-Enter using the correct code

MODE 2

 &

MODE 3

 - Deleting Fobs

Example

Indication

1

Enter into Programming mode as shown on page 4.

2 Enter Function code 33 then EN

FUN  33  EN

OK indicator flashes

3 Enter option 0 then EN

0 EN

OK indicator flashes

6 Enter the 10 Digit Fob number then EN

0001234567  EN

Long Bleep and Power indicator flashes

7 Exit Programming Mode:

FUN  2  EN

Long Bleep and OK indicator flashes once

To Delete a single Fob by Number:

Example

Indication

1

2 Enter Function code 32 then EN

FUN  32  EN

OK indicator flashes

3 Enter Group Number (01 to 20) then EN

01  EN

OK indicator flashes

4 Exit Programming Mode:

FUN  2  EN

Long Bleep and OK indicator flashes once

To Delete a Group of Fobs by Fob
Number:

Enter into Programming mode as shown on page 4.

6

Web: www.tatecolson.co.uk            E-mail:[email protected]                                           Tel: 01704-502801                  Fax: 01704-502810

Summary of Contents for APX-03

Page 1: ...Fob and 4 Digit Group Code Mode 3 User Fob Group code Deleting a Single Fob Deleting a Group of Fobs Mode 2 3 Page 7 Restoring a Deleted Fob Changing Lock open Time Bell ringing time Changing the Mas...

Page 2: ...on Keypad must be fixed to a flat and level surface The recommended fixing height is 1 1 5 metres from the floor If fixing more than 1 keypad ensure there is a gap of at least 50cm 20 to avoid interfe...

Page 3: ...tail for Electric Release including Exit Button Link the Yellow wire to the Red wire Com N O Exit Button OK OK 1 1 2 2 3 3 FUN FUN 4 4 5 5 6 6 7 7 8 8 9 9 CLR CLR 0 0 EN MENU MENU F U S E N E L O P O...

Page 4: ...nge and Grey wires are not used Magnetic Locks 12v DC Com N C Emergency Call Point Volt Free Relay Note Linking wiring from one magnet to the other will affect Holding force Note This wiring method ca...

Page 5: ...of the Keypad as this will not allow the unit to be programmed correctly If the wrong information is entered the Error indicator will flash once along with a low tone bleep then the keypad will retur...

Page 6: ...Bleep and OK indicator flashes once To Add a Group of Fobs by Fob No Enter into Programming mode as shown on page 4 Example Indication 1 2 Enter Function code 31 then EN FUN 31 EN OK indicator flashe...

Page 7: ...ode entry Note To Delete a Group code follow the above programming but enter 0000 instead of the Group code When a Group code is deleted the Fobs will revert to Fob only Mode 2 operation Fob Code Oper...

Page 8: ...and Power indicator flashes 6 Exit Programming Mode FUN 2 EN Long Bleep and OK indicator flashes once To Change Lock open time Note The number of seconds must be entered as 3 digits I E 5 Seconds 005...

Page 9: ...r Adding a Master Fob when original Master Fob is Lost To Program a new Master Fob when the original has been lost you will need to remove the Front Cover of the Keypad and look for a label in the top...

Page 10: ...FIRST FOB No LAST FOB No GROUP 01 GROUP 11 GROUP 02 GROUP 12 GROUP 03 GROUP 13 GROUP 04 GROUP 14 GROUP 05 GROUP 15 GROUP 06 GROUP 16 GROUP 07 GROUP 17 GROUP 08 GROUP 18 GROUP 09 GROUP 19 GROUP 10 GROU...

Page 11: ...10 FOB No FOB No NAME FOB NUMBER NAME LIST CONT D NAME Photocopy this sheet if required...

Page 12: ...page 8 Lock does not open when I use my 4 Digit code Make sure you press CLR before the 4 Digit code and EN after the code Note The OK indicator should flash after CLR is pressed If the OK indicator...

Reviews: