background image

APX-03 Keypad & Proximity Reader Programming Instructions

 MODE 2 - User Fob only

Note:   The Keypad will hold up to 12,000 user Fobs which are split up into 20 Groups of 600 Fobs.
Each group of Fobs must be numbered consecutively.  Fobs can be programmed by number or by presenting the
lowest number Fob then the highest number Fob.   If you have several batches of Fobs each batch must be
entered into a different Group number.

Example

Indication

1

2 Enter Function code 31 then EN

FUN  31  EN

OK indicator flashes

3 Enter option 0 then EN

0 EN

OK indicator flashes

4 Enter Group Number (01 to 20) then EN

01  EN

OK indicator flashes

5 Enter the lowest 10 Digit Fob number

0001234567  EN

2 Bleeps and OK indicator  flashes to confirm

6 Enter the highest 10 Digit Fob number

0001234616  EN

Double Bleep and Power indicator flashes

7 Exit Programming Mode:

FUN  2  EN

Long Bleep and OK indicator flashes once

To Add a Group of Fobs by Fob No:

Enter into Programming mode as shown on page 4.

Example

Indication

1

2 Enter Function code 31 then EN

FUN  31  EN

OK indicator flashes

3 Enter option 1 then EN

1 EN

OK indicator flashes

4 Enter Group Number (01 to 20) then EN

01  EN

Error and OK indicators start flashing

5

When indicators start flashing present
lowest number Fob in front of buttons

Present Lowest Fob

Short Bleep & OK indicator flashes once

6

When indicators start flashing present
highest number Fob in front of buttons

Present Highest Fob

Long Bleep and Power indicator flashes

7 Exit Programming Mode:

FUN  2  EN

Long Bleep and OK indicator flashes once

To Add a Group of Fobs using Fob:

Enter into Programming mode as shown on page 4.

Fob Operation: To use the Fob simply hold in front of the buttons within 7cm.  If Accepted you will hear a
short Bleep & OK will Flash. If Rejected you will hear a long Bleep & Error will flash once.

5

Web: www.tatecolson.co.uk            E-mail:[email protected]                                           Tel: 01704-502801                  Fax: 01704-502810

Summary of Contents for APX-03

Page 1: ...Fob and 4 Digit Group Code Mode 3 User Fob Group code Deleting a Single Fob Deleting a Group of Fobs Mode 2 3 Page 7 Restoring a Deleted Fob Changing Lock open Time Bell ringing time Changing the Mas...

Page 2: ...on Keypad must be fixed to a flat and level surface The recommended fixing height is 1 1 5 metres from the floor If fixing more than 1 keypad ensure there is a gap of at least 50cm 20 to avoid interfe...

Page 3: ...tail for Electric Release including Exit Button Link the Yellow wire to the Red wire Com N O Exit Button OK OK 1 1 2 2 3 3 FUN FUN 4 4 5 5 6 6 7 7 8 8 9 9 CLR CLR 0 0 EN MENU MENU F U S E N E L O P O...

Page 4: ...nge and Grey wires are not used Magnetic Locks 12v DC Com N C Emergency Call Point Volt Free Relay Note Linking wiring from one magnet to the other will affect Holding force Note This wiring method ca...

Page 5: ...of the Keypad as this will not allow the unit to be programmed correctly If the wrong information is entered the Error indicator will flash once along with a low tone bleep then the keypad will retur...

Page 6: ...Bleep and OK indicator flashes once To Add a Group of Fobs by Fob No Enter into Programming mode as shown on page 4 Example Indication 1 2 Enter Function code 31 then EN FUN 31 EN OK indicator flashe...

Page 7: ...ode entry Note To Delete a Group code follow the above programming but enter 0000 instead of the Group code When a Group code is deleted the Fobs will revert to Fob only Mode 2 operation Fob Code Oper...

Page 8: ...and Power indicator flashes 6 Exit Programming Mode FUN 2 EN Long Bleep and OK indicator flashes once To Change Lock open time Note The number of seconds must be entered as 3 digits I E 5 Seconds 005...

Page 9: ...r Adding a Master Fob when original Master Fob is Lost To Program a new Master Fob when the original has been lost you will need to remove the Front Cover of the Keypad and look for a label in the top...

Page 10: ...FIRST FOB No LAST FOB No GROUP 01 GROUP 11 GROUP 02 GROUP 12 GROUP 03 GROUP 13 GROUP 04 GROUP 14 GROUP 05 GROUP 15 GROUP 06 GROUP 16 GROUP 07 GROUP 17 GROUP 08 GROUP 18 GROUP 09 GROUP 19 GROUP 10 GROU...

Page 11: ...10 FOB No FOB No NAME FOB NUMBER NAME LIST CONT D NAME Photocopy this sheet if required...

Page 12: ...page 8 Lock does not open when I use my 4 Digit code Make sure you press CLR before the 4 Digit code and EN after the code Note The OK indicator should flash after CLR is pressed If the OK indicator...

Reviews: