APX-03 Keypad & Proximity Reader Programming Instructions

Initial Power up

On initial power up of the Keypad the Error, OK and Power indicators will light up. Wait for 3 long Bleeps, then a
short Bleep followed by the Error and OK lights flashing. Within 10 seconds present the Fob you want to set as
the "Master" in front of the buttons. A long bleep will sound to confirm the Fob is programmed as the "Master".

Important Note: The Fob with the lowest number must be used as the "Master" Fob and clearly marked as
"MASTER" . It must also be kept in a safe place for future use after the system is Programmed.
If the Master Fob is lost you will have to add a new one as shown on page 8.

If the keypad does not respond

with 3 bleeps you will need to follow instructions for Adding a Master fob when original is lost as shown on page 8.

OK

Key to Indicators:          = Error.           = OK.            = Power.

The APX03 Keypad can be programmed to operate in 3 different modes:-

Mode 1 - 4 Digit Code only

Mode 2 - Fob only

Mode 3 - Fob + 4 Digit Group Code

Any or all three of the above modes can be used at the same time as long as the Fobs for mode 3 are set in to a
different Group to the Fobs for mode 2. When Fobs are added they must be programmed as a group of consecutive
numbers. If you have several batches of consecutive numbered Fobs each batch must be programmed into a
different Group number. Ensure the Codes and Fob numbers are written on the System Record Sheet (Page 9&10)

Important Note: When pressing the buttons during programming ensure you do not have any Fobs in your
hand or within 15cm of the Keypad as this will not allow the unit to be programmed correctly.
If the wrong information is entered the Error indicator will flash once along with a low tone bleep then the
keypad will return to the beginning of programming and the Power indicator will flash.  Re-enter the
Function code number and continue to enter the programming information.

Note: Before any programming can be done you must put the keypad into Programming Mode:-

Example

Indication

1 Enter Function code 2 then EN

FUN  2  EN

Error and OK indicators flash

2 Present Master Fob

Present Master Fob

Short Bleep and  OK indicator flashes

3 Enter Master code then EN

1234 EN

Long bleep and Power indicator flashes

Note: The Default Master Code is 1234. We recommend this is changed after programming (see page 7).

To Enter programming mode:

 MODE 1 -   4 Digit User Code only  -  Up to 5 Codes can be programmed

Note: To Delete a User code follow above programming but enter "0000" instead of the user code.

Example

Indication

1

2 Enter Function code 46 then EN

FUN  46  EN

OK indicator flashes

3 Enter Slot No.(01 to 05) then EN

01 EN

OK indicator flashes

4 Enter new 4 digit User Code then EN:

4321  EN

OK indicator flashes

5 Re-Enter new User Code then EN:

4321  EN

Long Bleep and Power indicator flashes

6 Exit Programming Mode:

FUN  2  EN

Long Bleep and OK indicator flashes once

Enter into Programming mode as above

To Add a 4 Digit User code:

Code Operation: To use the code press CLR button (OK indicator flashes) - enter 4 digit code then EN.

Example: CLR - 4321 - EN. If the code is correct the OK indicator will flash once. If code is incorrect a short
tone will sound and the Error indicator will flash once.

4

Web: www.tatecolson.co.uk            E-mail:[email protected]                                           Tel: 01704-502801                  Fax: 01704-502810

Summary of Contents for APX-03

Page 1: ...Fob and 4 Digit Group Code Mode 3 User Fob Group code Deleting a Single Fob Deleting a Group of Fobs Mode 2 3 Page 7 Restoring a Deleted Fob Changing Lock open Time Bell ringing time Changing the Mas...

Page 2: ...on Keypad must be fixed to a flat and level surface The recommended fixing height is 1 1 5 metres from the floor If fixing more than 1 keypad ensure there is a gap of at least 50cm 20 to avoid interfe...

Page 3: ...tail for Electric Release including Exit Button Link the Yellow wire to the Red wire Com N O Exit Button OK OK 1 1 2 2 3 3 FUN FUN 4 4 5 5 6 6 7 7 8 8 9 9 CLR CLR 0 0 EN MENU MENU F U S E N E L O P O...

Page 4: ...nge and Grey wires are not used Magnetic Locks 12v DC Com N C Emergency Call Point Volt Free Relay Note Linking wiring from one magnet to the other will affect Holding force Note This wiring method ca...

Page 5: ...of the Keypad as this will not allow the unit to be programmed correctly If the wrong information is entered the Error indicator will flash once along with a low tone bleep then the keypad will retur...

Page 6: ...Bleep and OK indicator flashes once To Add a Group of Fobs by Fob No Enter into Programming mode as shown on page 4 Example Indication 1 2 Enter Function code 31 then EN FUN 31 EN OK indicator flashe...

Page 7: ...ode entry Note To Delete a Group code follow the above programming but enter 0000 instead of the Group code When a Group code is deleted the Fobs will revert to Fob only Mode 2 operation Fob Code Oper...

Page 8: ...and Power indicator flashes 6 Exit Programming Mode FUN 2 EN Long Bleep and OK indicator flashes once To Change Lock open time Note The number of seconds must be entered as 3 digits I E 5 Seconds 005...

Page 9: ...r Adding a Master Fob when original Master Fob is Lost To Program a new Master Fob when the original has been lost you will need to remove the Front Cover of the Keypad and look for a label in the top...

Page 10: ...FIRST FOB No LAST FOB No GROUP 01 GROUP 11 GROUP 02 GROUP 12 GROUP 03 GROUP 13 GROUP 04 GROUP 14 GROUP 05 GROUP 15 GROUP 06 GROUP 16 GROUP 07 GROUP 17 GROUP 08 GROUP 18 GROUP 09 GROUP 19 GROUP 10 GROU...

Page 11: ...10 FOB No FOB No NAME FOB NUMBER NAME LIST CONT D NAME Photocopy this sheet if required...

Page 12: ...page 8 Lock does not open when I use my 4 Digit code Make sure you press CLR before the 4 Digit code and EN after the code Note The OK indicator should flash after CLR is pressed If the OK indicator...