Summary of Contents for Premier RKP16

Page 1: ...Installation Manual PREMIER RKP4 8 16 RKP8PLUS 16PLUS INS181 4 ...

Page 2: ...nstallation 3 1 1 Mounting RKP8 16 Plus 3 1 2 Mounting RKP4 8 16 3 1 3 Selecting an Address 5 1 4 Cable Entry RKP4 8 16 5 1 5 Wiring 7 1 6 Programming Confirm Devices 7 1 7 Technical Specifications 8 1 8 Standards 9 1 9 Warranty 9 ...

Page 3: ...e of the unit Gently push the screwdriver to ease the retaining clips upward DO NOT LEVER OR TWIST Excessive force is NOT required The front flap and front cover can now be removed 1 2 Mounting RKP4 8 16 Open the keypad by carefully inserting a small flat blade screwdriver into both screw covers The PCB assembly is hinged for easy access Alternatively the PCB assembly can be unclipped and complete...

Page 4: ...INS181 4 4 9 ...

Page 5: ...ess Each keypad MUST be given a different address using the DIP switch on the left hand side of the PCB as follows N NEVER set two RKPs to the same address Keypads are factory set to Address 1 all switches off 1 4 Cable Entry RKP4 8 16 ...

Page 6: ...INS181 4 6 9 Cable entry MUST use either the top left hand hole or the cable channel NEVER run cables behind the PCB ...

Page 7: ... on 0V will be more beneficial than doubling up on 12V and 0V Keypad Zones The Premier RKP8 16 Plus has two fully programmable zone inputs Z1 COM Z2 For information on wiring configuration options please refer to the Premier 412 816 Installation Manual In order to use the keypad zones you must first enable the zones using Menu 43 Option 1 refer to the Premier 412 816 Installation Manual When a keyp...

Page 8: ...es exit installer menu and returns to day mode operation 5 N Any premier International panels containing a software version prior to V14 02 that is flashed with version V14 02 or later The Confirm Devices strings are not loaded in the panel s memory so any reference to them results in black squares being shown Reload English Text Strings This can be achieved by entering the Installers code and the...

Page 9: ...vice does not contain lead mercury cadmium hexavalent chromium polybrominated biphenyls PBB or polybrominated depheny ethers PBDE in more than the percentage specified by EU directive 2002 95 EC except exemptions stated in EU directive 2002 95 EC annex This product Type B Moveable device And is suitable for use in systems designed to comply with EN 50131 1 EN50131 3 at Grade 2 and Environmental Cla...