72
Don’t use the appliances if its cable
8.
sheath is damaged.
Don’t use the electric devices which re-
9.
quire continues power supply like med-
ical equipment. since AC power supply
may get interrupt based on the vehicle
condition
Don’t use the load which required high
10.
power at the starting/initial operation
Don’t use the loads which is sensitive
11.
to Inverter type AC supply
Don’t touch V2L adaptor socket side
12.
during V2L function
Don’t keep the V2L adaptor caps open
13.
after the use to ensure it is not ex-
posed to mud/metal particle etc.
Don’t start V2L charging function if Ve-
14.
hicle SoC is lesser than 30%.
Don’t perform V2L charging during rain
15.
or in any situation where it might be ex-
posed to water
Don’t press V2X switch and fascia
16.
switch together to stop the function.(
keep minimum 5sec delay)
Don’t disengage the park brake during
17.
V2L charging
Don’t mishandle the V2L adaptor.
18.
Do not insert the V2L connector when
19.
vehicle is in Crank or EV ready condi-
tion.
Don’t shift the gear
20.
Don’t disassemble or remodel the V2L
21.
adaptor
Don’t Drop the V2L adaptor to cause
22.
high impact and don’t keep heavy ob-
jects over the adaptor
Vehicle Ignition ON state
Turn ON the source vehicle ignition.
1.
Make sure to keep the vehicle in Igni-
tion ON mode throughout the proce-
dure.
Make sure to engage the park-
2.
brake/EPB.
Make sure to keep the vehicle and the
3.
V2L adaptor in dry environment/in
shade.
Remove the caps & connect the V2L
4.
adaptor gun to the source vehicle.
Connect external load to the V2L
5.
adaptor 3pin socket.
Make sure that Electrical loads to
•
be used for V2L charging are
healthy/in good condition and en-
sure the relevant cables and plugs
of loads are connected properly.
Total power consumption of the
•
loads used should be lesser than
3.3Kw and it is recommended to
use the loads with Power factor
greater than 0.85
In case of multiple loads, it is rec-
•
ommended to use extension box
with MCB (16A) & with M Type plug
and socket.
Press the V2X switch to start the 220V
6.
AC power supply.( check for the HMI).
Ensure safety precaution against the
7.
live 220VAC voltage in the V2L adap-
tor
Turn on the loads.
8.
Check telltale indication in instrument
9.
cluster to ensure discharging is initi-
ated/in progress.( check for the HMI)
Check for the telltale indication fre-
10.
CHARGING
Summary of Contents for Nexon EV 2003
Page 2: ...REV 00 NOV 2023 OWNER S MANUAL...
Page 5: ...iv...
Page 30: ...Wrong Seating Positions SAFETY 21...
Page 37: ...28 SAFETY...
Page 62: ...Normal Charging Control Box Indica tions Home 1 Control Box 2 Vehicle 3 Fault 4 CHARGING 53...
Page 95: ...86 DIGITAL DISPLAY 7 Inch If equipped INSTRUMENT CLUSTER...
Page 109: ...100 Trip Information INSTRUMENT CLUSTER...
Page 110: ...Drive Assist INSTRUMENT CLUSTER 101...
Page 111: ...102 Vehicle Information INSTRUMENT CLUSTER...
Page 112: ...Energy Analytics INSTRUMENT CLUSTER 103...
Page 113: ...104 Notification INSTRUMENT CLUSTER...
Page 114: ...Layout INSTRUMENT CLUSTER 105...
Page 115: ...106 Setting Screen INSTRUMENT CLUSTER...
Page 116: ...DIGITAL DISPLAY 10 25 Inch INSTRUMENT CLUSTER 107...
Page 203: ...194 INFOTAINMENT SYSTEM DISPLAY Option I Option II Option III INTERIOR FEATURES...
Page 233: ...224 Steps hTab EMERGENCY AND BREAKDOWN...
Page 240: ...Steps hTab EMERGENCY AND BREAKDOWN 231...
Page 271: ...262 VEHICLE DIMENSIONS NOTE Dimensions are in mm unladen condition TECHNICAL SPECIFICATIONS...
Page 308: ......