If vehicles have been manually removed from a siding or parked there in the switched-off
state, HADES sets the entry turnouts according to the current occupancy status.
5.2. Malfunctions and fault messages
HADES detects malfunctions that can lead to accidents in the staging yard and then stops
operation. The causes of the faults are indicated on LEDs on modules.
Failure of the track voltage (e.g. after a short circuit)
All states (track occupancy messages, positions of turnouts) are automatically "frozen".
Display
Basic module:
The red and green LEDs for track 2 light up simultaneously
Continuation of operation
As soon as the track voltage is applied again, operation
continues automatically without further interruption with the
previous settings.
Remaining of a wagon in the siding
HADES detects a fault if a vehicle (with current consumption) is still in the siding after the set
departure time (→ section 5.3.) has elapsed. If the fault is not due to a wagon that has
broken off, you must adjust the departure time (→ section 5.3.)
Display
Base or track modules:
The red and green LEDs for the occupied/ vacant display of the
relevant track flash alternately.
Continuation of operation
After removing the wagon, a restart must be carried out.
Failure of a track module
HADES recognises a malfunction if a track module no longer responds to the queries carried
out at intervals of approx. 0.5 seconds. Causes can be a defect in the module or a loosened
connection between base and track module.
Display
Basic module:
The three LEDs used to indicate the set operating mode
produce a running light.
Continuation of operation
After rectifying the fault, a restart must be carried out.