tams elektronik
!
HADES
t
a
ms elektronik
7. Technical data
Interfaces, outputs and inputs
Connection of further modules Basic module: 1 x RJ45
Track module: 2 x RJ 45
Outputs
Entry turnouts: 2 per module
for direct connection of turnouts with double coil drive
for connection of motor-run turnouts or turnouts with
servo drive:
additional controllers required
Sidings: 2 per module
2 separate track sections per siding, one of which has
an integrated track occupancy detector
Outputs
(use optional)
2 for 4 external occupancy indicator LEDs per module
Supply voltage: 5 V constant
Inputs
(use optional)
2 inputs for external exit push-buttons per module
1 input for external on/off switch or comparable circuit
(basic module only)
Electrical characteristics
Power supply of the modules
12 - 18 volts direct or alternating voltage
Note: HADES provides the current for switching the entry
turnouts. The power supply must therefore be matched to
the nominal size and the type of turnout.
The modules must
not
be supplied via a transformer
that is also used as an analogue driving current
transformer or to supply the digital system!
For further information → 2.8. "Power supply"
Supply of the tracks in the
staging yard
via the analogue driving transformer
or the digital track voltage
Current consumption of the
circuit
approx. 60 mA
(without external consumers such as turnouts, LEDs,
buttons)
Maximum output current
3,000 mA per siding
32 | Technical data