4.3. Connecting the entry turnouts
Odd number of sidings
If there is an odd number of sidings in the staging yard, the last track module will be
configured to monitor and control only one siding (see section 4.2.). Connections 5 and 7
(siding 2 of the relevant track module) as well as 9, 11 and 13 (entry switch 2 of the relevant
track module) will then remain free.
Testing the functionality of the turnouts
Always test after connecting the turnouts to base or track modules whether they are fully
functional and "correctly" switched, i.e.
with occupied track on "through" (in the direction of the through track or exit),
if the track is free, to "branch" (in the direction of the siding).
Caution:
The correct connection of the entry turnouts and the reliable function of the turnouts are
decisive for the safe function of the control system! In case of malfunctions, entering trains
can cause accidents!
Connections | 21