9. Check list for troubleshooting
The booster is getting very hot and / or starts to smoke.
Disconnect the system from the mains immediately!
Possible reason: The connections to the track and the power supply
have been mixed up.
à
Alter the connections. Possibly the booster
has been damaged.
Problems with switching on and data transfer
The LED at the booster does not light and the locomotives cannot be
driven.
Possible reason: The power supply has been interrupted.
à
Check
the connections to the power supply (transformer).
The booster cannot be switched on or it transfers faulty signals
(locomotives do not react as intended).
Possible reason: The terminating jumpers have not been mounted
although the booster is installed at one end of the data line.
Possible reason: The terminating jumpers have been mounted
although the booster is not installed at one end of the data line.
The LED flashes in the colour yellow
The LED flashes slowly in the colour yellow.
Possible reason: The control unit has been switched off or the
connection to the control unit has been interrupted.
à
Check the
control unit and the connections.
Possible reason: The wrong port (DCC conformin / BiDiB) has been
determined. Check the settings in CV## 53 – 55 or the setting of the
jumpers JP2, JP3 and JP4.
Page 32
Summary of Contents for 40-19507
Page 1: ...t a m s e l e k t r o n i k Manual BiDiBooster Item no 40 19507 tams elektronik n n n...
Page 37: ...t a m s e l e k t r o n i k BiDiBooster English Page 37...
Page 38: ...t a m s e l e k t r o n i k English BiDiBooster Page 38...
Page 39: ...t a m s e l e k t r o n i k BiDiBooster English Page 39...