![tams elektronik 40-19507 Manual Download Page 11](http://html1.mh-extra.com/html/tams-elektronik/40-19507/40-19507_manual_816269011.webp)
tams
elektronik
BiDiBooster
English
data via the interface (e.g. current, voltage and termperature). The
booster´s performance data are used as a basis for the booster
management of the PC control.
Using the ABC-braking method
The booster amplifies the track signal completely symmetrically. This
allows the ABC-braking method to be used in DCC-controlled layouts.
The DCC-input of the BiDiBooster is isolated through an opto-coupler.
Balanced track voltage
The BiDiBooster provides a regulated track voltage, which can be set to
a value between 10 and 24 V in 1 V-steps. At delivery the track voltage
is set to 18 V.
Regulating the track voltage to a constant value prevents changes in
locomotive speeds and lighting brightness, resulting from voltage
variations.
Rated size
Recommended track
voltage
Value in state of delivery
Z
12 V
N and TT
14 V
H0
18 V
18 V
0, I and II
20 - 24 V
Page 11