![tams elektronik 40-19507 Manual Download Page 23](http://html1.mh-extra.com/html/tams-elektronik/40-19507/40-19507_manual_816269023.webp)
tams
elektronik
BiDiBooster
English
7. Settings
The BiDiBooster can be set to individual requirements
via BiDiB with a PC software or
by programming on main (POM) or
by inserting short-circuit terminations (jumpers).
Possible settings
Manu-
facturers
settings
Setting
with
jumpers
Track voltage
10 – 24 V, to be
set in 1 V-steps
18 V
no
Autostarting time
after a short circuit
4 – 10 sec., to be
set in 1 sec.-steps
4 sec.
no
Max. track current
(interrupting current
after a short circuit)
2 – 4 A,
to be set
in 1 A-steps
3 A
yes
RailCom
active or inactive
active
no
Switching off with a
DCC points
switching command
active or inactive /
assigning the
points address
inactive
no
Watchdog
active or inactive /
assigning the
points address
inactive
no
Time elapsing til the
short circuit switch
off reacts
1- 255 ms
100 ms
no
Autostarting time
after 5 short circuits
0 – 90 sec.
60 sec.
no