BiDiBooster
Possible settings
Manu-
facturers
settings
Setting
with
jumpers
Time for inrush
current limiting
2 - 500 ms
100 ms
no
Determining the
port
BiDiB-interface,
DCC-interface or
reception of the
booster signals via
the DCC-booster
port and
transmission via
the RJ 45-booster
port
DCC-
interface
yes
7.1. Programming via BiDiB
As soon as the BiDiBooster is connected to a BiDiB controlled and
monitored layout, it is integrated automatically into the PC layout
control. By aid of the PC control software or (when not possible with
this software version) special tools (e.g. BiDiB-Monitor or BiDiB-Wizard)
the booster specific configuration variables (CVs) and the BiDiB feature
settings are programmed. It is also possible to make a software update
via BiDiB.