3.4.6
Printed Output Appears Shaky or Fuzzy
There are six things that can cause this problem.
1.
The platen may be open too far.
2.
The hammers are not firing properly.
3.
Platen alignment may be incorrect.
4.
Damaged platen.
5.
The Shuttle Sensor is misaligned.
Step 1.
Run another print gap detection and verify that the print gap is at a reasonable
position by using the
PRINT GAP
adjust keys.
Step 2.
Perform a Hammer Calibration procedure. This procedure is explained in Chapter 2,
in the
TEST
Menu Section, under the
Diagnostic
Category (
PrntCal
Parameter).
If the hammers can not be calibrated, the problem is in the Controller CBA. Replace
the Controller CBA following the procedure explained in Chapter 4.
Step 3.
Check and adjust the platen alignment guides. The Platen Gap should be .012 "
–
.014" with the platen fully closed.
Step 4.
Check the impact area of the platen and replace the platen if this area is damaged.
Summary of Contents for 6300 Series
Page 1: ......
Page 24: ...6300 Series Maintenance Manual 18...
Page 54: ...6300 Series Maintenance Manual 48...
Page 83: ...Appendix A Drawings 77 Appendix A Drawings 6306 Drawings...
Page 110: ......
Page 111: ......
Page 112: ......
Page 115: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ...6300 Series Maintenance Manual 78 6312 Drawings...
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 161: ......
Page 167: ......
Page 168: ......
Page 169: ......
Page 170: ......
Page 171: ......
Page 172: ......
Page 173: ......
Page 174: ......
Page 175: ......