Area of Rescue Command Unit

 

Installation Guide 

Model AOR-24 / Model AOR-32 

Product Revision 2.0

 

Page 

3

 of 

23

 

 

 

Rev. 3/8/2022

 

 

Copyright 2014-2022 Talk-A-Phone, LLC

 

• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.  

 

All prices and specifications are subject to change without notice. Talk-A-Phone, Talkaphone, bAlert, Scream Alert, WEBS, and WEBS Contact are registered trademarks of 
Talk-A-Phone, LLC.  All rights reserved.  All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate 
any approval, endorsement, sponsorship, or affiliation with such owners unless such approval, endorsement, sponsorship, or affiliation is expressly indicated. 

IV. 

System Overview 

1.  Local Mode 

 

In Local Mode, pressing the button on any of the Talkaphone Analog Call Stations will cause the 
built-in local phone at the command unit to ring. 

2.  Remote Mode 

In Remote Mode, pressing the  button  on  any of the Talkaphone  Analog Call Stations  will cause 
them to access a phone line to dial out.  For this configuration, connect an outside phone(s) line 
to the “Telco IN” position(s) on the appropriate bank(s). 

3.  Mixed Mode 

 

Mixed Mode is primarily used when a central control point is not constantly attended at all times.  
When a Talkaphone Analog Call Station calls and the 

AOR-24 / AOR-32 

unit is in Mixed Mode, it 

will ring the 

AOR-24 / AOR-32 

command unit

’s built-in local phone first, ring it a second time if no 

one answers the first time, then if no one answers the second time it will dial a remote number.  If 
no one should answer the remote number, it will re-ring the local phone and continue this cycle 
until either the phone is answered or times out (See 

Emergency Phone Manual

 for information 

on setting the time-out). 
When an attendant leaves, that person can enter the code 

*36*

 to configure the controller board 

to ring the remote phone first and then switch to the local phone (See p.14, 

Section VII

System 

Programming

).  For Mixed Mode, connect an outside phone line(s) to the 

“TELCO IN”

 

terminal(s).  This programming must be done for each of the controller boards (three (3) controller 
boards for the AOR-24 or four (4) controller boards for the AOR-32). 

 

NOTE:

 See p.2, 

Technical Requirements

, for outside phone line requirements. 

 

 

 

Summary of Contents for AOR-24

Page 1: ...del AOR 24 or Model AOR 32 For instructions on installation or programming of Talkaphone Area of Rescue Call Stations please refer to the manual for the AOR CSE Analog Call Station It is recommended t...

Page 2: ...ded pair specifically designed for use with analog telephones Connect shield to earth ground at the Command Unit Distance ranges for recommended wire gauges are provided in the table below Distance fr...

Page 3: ...cess a phone line to dial out For this configuration connect an outside phone s line to the Telco IN position s on the appropriate bank s 3 Mixed Mode Mixed Mode is primarily used when a central contr...

Page 4: ...ll rights reserved All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate any approval endorsement sponsorship or affilia...

Page 5: ...k A Phone LLC All rights reserved All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate any approval endorsement sponsor...

Page 6: ...e command unit local phone by sliding it upwards about 1 2 inch then lifting away from the command unit and out of the compartment This will expose the local phone mounting points within the command u...

Page 7: ...Please note that two 2 of the mounting keyholes are located behind the local phone The local phone will need to be removed and the phone line power cables will need to be disconnected 8 Flush Mountin...

Page 8: ...e two 2 quick connects terminated onto yellow and yellow white wires to the relay input on the addressable FACP 11 Connecting to Relay Output for Fault Conditions a Normally closed NC outputs are avai...

Page 9: ...s and does not imply or indicate any approval endorsement sponsorship or affiliation with such owners unless such approval endorsement sponsorship or affiliation is expressly indicated 13 Routing Cabl...

Page 10: ...ne line or analog PBX extension line is to be used for off site dialing terminate the analog telephone line or PBX extension line to the TELCO IN terminals for each respective bank these connections a...

Page 11: ...any approval endorsement sponsorship or affiliation with such owners unless such approval endorsement sponsorship or affiliation is expressly indicated 17 Connecting Primary Power Once the appropriate...

Page 12: ...hip or affiliation with such owners unless such approval endorsement sponsorship or affiliation is expressly indicated 18 Connecting Backup Batteries Install the backup batteries and connect them to t...

Page 13: ...digits Guard Access Code entry for phone programming Default 31 30 up to 8 digits Master Access Code entry to change Guard Access Code or Master Access Code Default 30 12345678 30 14725836 Resets cont...

Page 14: ...n 3 Remote Mode In Remote Mode the controller board s does do not require any programming Move onto Programming the AOR CSE Stations 4 Local Mode 1 AOR 24 This command unit has three 3 controller boar...

Page 15: ...and does not imply or indicate any approval endorsement sponsorship or affiliation with such owners unless such approval endorsement sponsorship or affiliation is expressly indicated Pick up the loca...

Page 16: ...ause and then the AOR CSE Station will answer with an open channel i e microphone and speaker are active 2 Enter the security code 827827 or TAPTAP 3 Program the Primary Phone Number to dial 0 20 digi...

Page 17: ...All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate any approval endorsement sponsorship or affiliation with such own...

Page 18: ...the AOR CSE Station Command Memory Slot Function 0 20 digits 00 Primary autodial phone number 0 20 digits 01 Secondary autodial phone number 0 20 digits 02 Third autodial phone number 0 20 digits 03 F...

Page 19: ...elow Parameter Function Values Definition A Talk Listen Delay Switching time between talk and listen modes i e VOX switching time 1 0 1 seconds 2 0 2 seconds Default 3 0 3 seconds 4 0 4 seconds 5 0 5...

Page 20: ...at were waiting will be put through in the order in which they were placed 2 Calling Into AOR CSE Stations from the Command Unit 1 To call from a remote phone dial the telephone number of the phone li...

Page 21: ...rts When a short occurs on an AOR CSE Station cable run both the respective TROUBLE LED s and the STATION STATUS LED s will solidly illuminate on the Command Unit panel indicating the specific port s...

Page 22: ...ed and tested The Command Unit should be inspected and tested Verify the condition of the backup batteries and replace if necessary XI Frequently Asked Questions 1 If I have more than one Command Unit...

Page 23: ...r analog PBX extension line may not have been properly terminated inside the Command Unit Verify the internal connections 3 The cabling for the PSTN POTS telephone line or analog PBX extension line ma...

Reviews: