Area of Rescue Command Unit
Installation Guide
Model AOR-24 / Model AOR-32
Product Revision 2.0
Page
13
of
23
Rev. 3/8/2022
Copyright 2014-2022 Talk-A-Phone, LLC
• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.
All prices and specifications are subject to change without notice. Talk-A-Phone, Talkaphone, bAlert, Scream Alert, WEBS, and WEBS Contact are registered trademarks of
Talk-A-Phone, LLC. All rights reserved. All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate
any approval, endorsement, sponsorship, or affiliation with such owners unless such approval, endorsement, sponsorship, or affiliation is expressly indicated.
VII.
System Programming
List of Programming Codes for the Command Unit
Command
Function
* 31 * [up to 8 digits] *
Guard Access Code entry for phone programming
[Default * 31 * *]
* 30 * [up to 8 digits] *
Master Access Code entry to change Guard Access Code or
Master Access Code
[Default * 30 * 12345678 *]
* 30 * 14725836 *
Resets controller board programming to factory defaults.
Requires prior Master Access Code entry.
* 32 * [up to 8 digits] *
Programs and stores a new Master Access Code.
Requires prior Master Access Code entry.
* 33 * [up to 8 digits] *
Programs and stores a new Guard Access Code.
Requires prior Master Access Code entry.
* 34 * [up to 2 digits] *
Sets number of rings before controller board picks up when it is
dialed
[Default 3]
* 35 *
In Mixed Mode, call LOCAL PHONE then TELCO IN
* 36 *
In Mixed Mode, call TELCO IN then LOCAL PHONE
[Default with * 63 *]
* 37 *
Local Mode
NOTE:
All calls will route to the local phone.
* 62 *
Remote Mode
[Default Setting]
* 63 *
Mixed Mode (Local and Remote)
* 4 [Select Port 1-8] *
Enter this code when connected through the local phone or a
remote call
– routes to a specific AOR-CSE Station on Port 1-8.
Does not require Guard Access Code or Master Access Code
entry.
#
Terminate Connection