7. Surface Mounting onto an Interior Wall:
The
AOR-24 / AOR-32
unit has four (4) surface mounting keyholes located on the rear of the
chassis.
Please note that two (2) of the mounting keyholes are located behind the local phone. The local
phone will need to be removed and the phone line/power cables will need to be disconnected.
8. Flush Mounting into an Interior Wall:
The
AOR-24 / AOR-32
has ten (10) 1/4-inch screw points on the top, bottom, and sides which
can be used to mount the Command Unit within a wall.
The
AOR-TR32
trim ring may be installed in contact with the closed cover without inhibiting the
functionality of the hinge. Secure both halves of the
AOR-TR32
to the wall using the provided 6-
18 screws.
9. Installation of Strobe/Siren:
Mount the strobe/siren assembly on a wall in an appropriate location per the instructions
packaged with the strobe/siren assembly.
Black, Red, and Orange lead wires
from the controller board(s) in the
AOR-24 / AOR-32
Command Unit’s
internal compartment.
The
Black wire is a common negative
and needs to be connected to
both the strobe and
siren negative terminals
.
The
Red wire
is connected to the
positive terminal of the strobe
.
The
Orange wire
is connected to the
positive terminal of the siren
.