IX. Troubleshooting
— 38 —
protection threshold, the over
voltage protection will run
automatically.
motorcycle to the nearest dealer
to inspect and repair.
39
00A00
Magnetic
encoder error
Magnetic encoder got a poor
contact or it's broken.
1. Check whether the magnetic
encoder got a poor contact? If yes,
repair it.
2. If the magnetic encoder is well
contacted, it means it's broken.
Please replace a new magnetic
encoder.
If the solution cannot solve the
error, please send the electric
motorcycle to the nearest dealer
to inspect and repair.
40
00B00
Motor phase wire
failure error
Motor phase wire loose or
incorrect connection caused the
error
Turn off the electric motorcycle,
and switch off the circuit breaker.
Then, check the whether the motor
phase wire terminal got loose, or
broken. And then, check whether
the motor outlet phase sequence
corresponds to the U / V / W on
the
controller.
Finally,
check
whether the magnetic encoder
output wire corresponds to the
yellow, green and blue wires on
the harness assy.
If the solution cannot solve the
error, please send the electric
motorcycle to the nearest dealer
to inspect and repair.
41
00C00
Motor
overtemperature
error
High-power operation for a long
time, high motor temperature or
poor contact or damage of
temperature sensor
It is recommended to use it after
the
temperature
protection
is
removed, or check whether the
motor encoder plug is loose.
42
00D00
Motor
temperature
sensor fault
Long time peak power riding
will cause the motor to be
overtemperature, or motor inner
1. Stop riding until the motor's
temperature return to normal.
2. Check whether the magnetic
38