TALARIA POWER TECH (CHONGQING) CO., LTD.
IX. Troubleshooting
— 36 —
31
00100
Setting error
It's
caused
by
the
faulty
operation during the production.
Send the electric motorcycle to the
nearest dealer to repair.
32
00300
Controller phase
wire over current
error
Controller phase wire current is
equal
or
greater than
the
protection threshold.
1. Turn off the electric motorcycle,
and switch off the circuit breaker.
Then, check the whether the motor
phase wire terminal got loose, or
broken. And then, check whether
the motor outlet phase sequence
corresponds to the U / V / W on
the controller. Finally, check
whether the magnetic encoder
output wire corresponds to the
yellow, green and blue wires on
the harness assy.
2. Check whether anything stuck
the rear wheel.
If the solution cannot solve the
error, please send the electric
motorcycle to the nearest dealer
to inspect and repair.
33
00400
Controller busbar
over current error
Controller busbar current is
equal
or
greater than
the
protection threshold.
1. Turn off the electric motorcycle,
and switch off the circuit breaker.
Then, check the whether the motor
phase wire terminal got loose, or
broken. And then, check whether
the motor outlet phase sequence
corresponds to the U / V / W on
the controller. Finally, check
whether the magnetic encoder
output wire corresponds to the
yellow, green and blue wires on
the harness assy.
2. Check whether anything stuck
If the solution cannot solve the
error, please send the electric
motorcycle to the nearest dealer
to inspect and repair.
36