116
MAINTENANCE
Daily Inspection (Every 10 Hours)
Perform the following inspections once every day before starting the engine the first time.
WARNING
�
Before operating, perform the Daily inspections and make repairs immediately should
any irregularities be found.
�
Be sure to secure the engine hood or cover when opening it. Do not open the engine
hood or cover on slopes or in strong wind.
Replenishing
1. Remove the reserve tank’s cap (2).
2. Add coolant up to the upper limit (H) of the
reserve tank (1).
If the reserve tank is empty, inspect for
fluid leakage, then inspect the radiator (3)
coolant level. If it is low, add water to the
radiator (3) first, then to the reserve tank.
3. Install the cap (2).
Inspecting and Replenishing the
Coolant
WARNING
Do not remove the radiator cap or drain
plugs when the coolant is hot. Stop the
engine, let the engine and radiator cool
and loosen the radiator cap or drain plugs
slowly.
Inspection
1. Open the engine hood and left side
cover.
2. Inspect the quantity of coolant in the
reserve tank (1).
The level should be between the upper limit
(H) and lower limit (L).
If it is below the lower limit (L), replenish.
FULL
LOW
W3G010
3
H
L
2
1
Summary of Contents for TB175W
Page 6: ...4...
Page 8: ...6...
Page 35: ...33 MEMO...
Page 98: ...96...
Page 103: ...101 TRANSPORT 2 Piece Boom Mono Boom Hoisting the Machine...
Page 168: ...166...
Page 171: ...169 MEMO...
Page 172: ...170 SPECIFICATIONS Machine Dimensions W2K0011 K R G J Q P M V W L N D H B C U S T E F A...
Page 174: ...172 SPECIFICATIONS Operating Range 2 Piece Boom W2K002 J E F G C D K H B A...
Page 176: ...174 SPECIFICATIONS Operating Range Mono Boom W2K003 J K H B A D G F E C...
Page 178: ...176 MEMO...
Page 184: ...182...
Page 212: ...210...
Page 213: ...211 INDEX...