To ensure that this product can be used for a long period of time, conduct the inspections below.

When repair is necessary, contact the nearest dealer or Takara Belmont directly.

 Inspect the product every day

Inspectionitem

Inspection method

If the inspection results show defects

Is the basin unit not 

wet with water?

Is the mounting 

surface of the basin 

unit not wet with 

water?

Have the neck cushion 

and head pillows not

degraded?

Is there no abnormal 

odor coming from the 

drain outlet?

Does the tap work 

properly?

Is there no peeling 

found on the tap or 

thermostatic control 

knob?

Is water output from 

the shower head 

properly?

Does the

themostatic control

knob work properly?

Check if the parts except inside

of the basin is not wet.

Visually check the mounting 

surface of the basin unit and check 

it is not wet with water.

Check that there is no tearing, dirt 

or sinking on the surface of the 

neck cushion and head pillows.

Check if there is no abnormal

odor coming from the drain

outlet.

Turn the tap and check if warm 

water is discharged properly and 

there is no abnormal sounds. 

Then close the tap and check that 

warm water stops properly.

*An abnormal gushing sound may 

be emitted as water flows. (Refer 

to page 14 to 15.)

Visually check that if there is no 

scratches, cracks or peeling on the 

plated surface of the tap or 

thermostatic control knob.

Check if there is no abnormal

conditions found when performing

operation or maintenance. 

Turn on the tap, and visually check 

that water is discharged normally 

from the shower head, water is not 

leaking from the foaming water 

outlet, or the hot water is not 

turbid.

Turn the thermostatic control 

knob, check that the water 

temperature is adjusted properly 

and that there is no abnormal 

sound.

*An abnormal gushing sound may 

be emitted as water flows. (Refer 

to page 14 to 15.)

It may cause malfunction of the product, or stain 

may become hard to remove.

 Immediately wipe away the moisture adheres on 

the parts except inside of the basin.

There is a possibility that water is leaking inside 

of the basin unit. Open the maintenance cover 

and check inside (Refer to pages 26 to 28.). If 

water is leaking from the pipes, immediately stop 

using the product, contact the nearest dealer or 

Takara Belmont directly.

These may cause pain or transfer dirt to the 

client’s neck and head. The neck cushion and 

head pillows are consumable supplies. Replace 

them as soon as possible.

Remove any hair and other objects trapped

in the hair catcher. (Refer to page 23.)

If abnormal sounds are heard, or the warm water 

does not turn off properly even when the tap is 

closed firmly, there may be a malfunction in the 

stop valves of the tap. 

Contact the nearest dealer or Takara Belmont 

directly.

It may hurt your hands or fingers with the 

scratches, cracks or peeling on the surface of the 

plating, so immediately replace it. To replace the 

parts, contact the nearest dealer or Takara 

Belmont directly.

If water is leaking from the foaming water outlet 

or from the base of the shower head, the internal 

gasket may be worn out.

If replacement is required, contact the nearest 

dealer or Takara Belmont directly.

If hot water does not come out normally, or it is 

turbid, there is a possibility that the filter of the 

check valve is contaminated.

Clean the filter. (Refer to pages 26 to 28.)

When a few water line splashes out of the water 

flows, there is a possibility that lime scale or dirt 

may be contaminated in the shower head plate. 

Remove the shower head plate and clean it. 

(Refer to page 24.)

If the water temperature cannot be adjusted 

properly or if there is abnormal sounds, there 

may be a problem with the thermostat inside of 

the basin unit. S top using the product 

immediately, and contact the nearest dealer or 

Takara Belmont directly.

Procedures for Daily Inspections

Summary of Contents for YUME SWING

Page 1: ...esin Plated Parts Types of Layout and Standard Positions Preparation How to Use Guiding Clients Care and Maintenance Daily Inspections Before Requesting Repairs Parts Replaced on a Regular Basis Stand...

Page 2: ...not be conducted by people other than qualified repair technicians Failure to follow this instruction may cause water leakage or abnormal operation leading to injury Safety Precautions Adhere to these...

Page 3: ...o injury Also coloring dyes on the neck cushion or basin may stain the user s clothes Do not use hot water boiling water of 60 C or higher Using hot water of 60 C or higher may deform or damage the ba...

Page 4: ...sure to only use this product inside a hairdressing salon Failure to follow this instruction may cause malfunction or damage to the main unit Take care when handling the shower hose When using the bas...

Page 5: ...gienic conditions Try to clean the hair catcher after each shampoo Do not cover the drain outlet when this product is not going to be used Do not cover the drain outlet with the drain cap towel or sha...

Page 6: ...brasive compound Do not use an abrasive compound to clean the dual function shower head shower head holder cover etc Use of an abrasive compound sponge with abrasive compound or hard cleaning tools su...

Page 7: ...product Check the position of the basin and SWING arm before rotating the chair Depends on the fixed position of the chair foot footrest will hit the basin unit resulting in breakage of the chair or...

Page 8: ...when manufacturing the part and these are not a product failure Position of Warning Labels 8 Caster Cover Dual function shower head Shower Hose Rotation Arm Cover Maintenance Cover Caster Rail Neck Cu...

Page 9: ...ccessories have been attached properly Caster rail is to prevent floor from getting scratched while the caster of basin unit slides Please note in advance that surface of caster rail may degrade due t...

Page 10: ...ce when a hard object hits the surface Peeling of the plating may occur from scratches or cracks on the plated surface Check to ensure that there are no scratches cracks or peeling of the plated surfa...

Page 11: ...eck the Initial Position and Shampooing Position from the illustrations shown below Initial Position Shampooing Position Initial Position Shampooing Position Front Layout Rear Layout Wall Wall Wall Wa...

Page 12: ...the proper direction 2 Secure the snap buttons of neck cushion on the chair side to the fixing pins of metal fittings 3 While shaping the neck cushion along the metal fittings secure the snap buttons...

Page 13: ...il they snap into place Attach the sponge to the shower hose Attach the sponge and sponge holder to the shower hose between the shower head holder and the cover Do not remove the cover of holder forci...

Page 14: ...l stop the water When the basin is not being used turn the tap firmly full right clockwise to turn the water off properly Failure to do this may cause water leakage After shampooing do not cover the d...

Page 15: ...rsonal injury Caution Caution Depends on the operating environment or conditions the water discharge amount may change significantly when controlling the hot water temperature This phenomena occurs wh...

Page 16: ...not affect use A small amount of water may flow out but does not affect its convenient use If the decreasing level is significant the gasket of the drain cap may have deteriorated or become worn so r...

Page 17: ...and chair backrest When sliding the basin unit hold the edge of the basin and slide it Basin unit is locked at initial position and at shampooing position Slight click is felt when the basin is locke...

Page 18: ...seals attached to the chair base and lower cover 3 Unlock the chair rotation after the client seats on the chair and rotate it to the shampooing position 4 Slide the basin unit to shampooing position...

Page 19: ...with the basin When reclining the backrest hold the client s head by your hand to avoid client s head to hit the basin When unlocking the chair rotation while the client is laying on the chair to do...

Page 20: ...separately Product code ES ESST Adjusting the height of ESPOIR Stool 1 While seating on the stool raise the handle and release the lock 2 Adjust it to the desired height 3 Return the handle and lock...

Page 21: ...of product or personal injury When returning the basin unit return it to the initial position completely Failure to follow this instruction may allow the basin unit to contact to chair etc resulting...

Page 22: ...e to wipe off any moisture from all parts other than the basin Leaving the product with water drops may result in failure of the product or any contamination will not be removed Caution The drain cap...

Page 23: ...it is extremely dirty or the surface has deteriorated available at additional cost At the end of work each day wash the neck cushion and head pillows with water wipe them dry with a towel and allow t...

Page 24: ...water Clean it once a month measure Using a nylon or similar brush remove the dirt such as water stain from the foaming water outlet 4 Re assemble the shower head 1 Insert the foaming water outlet an...

Page 25: ...with both hands Clean the sponge every day After cleaning the sponge put it in the hose and put it back on the cover Sponge is consumable supply Replace the sponge if degradation causes rubbing sound...

Page 26: ...hen the basin is filled with water available at an additional cost Basin body Drain cap Gasket Drain cap Drain cap Removing water from filter and cleaning the filter When removing maintenance cover an...

Page 27: ...filters 4 With cloth cover the floor around the water and hot water supply pipes 5 Close stop valves of the hot water and water supply pipes If there are electrical components such as wires nearby ens...

Page 28: ...ter leakage 11 Return the maintenance cover to its original position using the Urea screw 1 pce removed at the process 1 10 Return the plumbing cover to its original position using the Urea screw remo...

Page 29: ...oca tions in total and detach the caster covers When the hair or dirt tangled with caster and it does not move smoothly clean the caster 2 Remove hair and dirt tangled with caster and clean it 3 Retur...

Page 30: ...temperature setup of the thermostatic control knob proper Is hair clogging the hair catcher Adjust the volume of the water Refer to pages 14 to 15 Adjust the temperature setup of the boiler to the pr...

Page 31: ...amage to the hose may result in water flooding on or beneath the floor Check valve Replace every three years When the check valve is used continuously for long periods of time there is a possibility t...

Page 32: ...pressure water pressure 0 1MPa respectively Dual function shower head Shower outlet 10 0L min Low splash foaming mode 6 5 L min Stop valve Single faucet rotary type Operating environment Operating tem...

Page 33: ...floor plumbing Overview Diagram Basin EX YMSBXYM2 YUME Basin Reverse Slide Spec Arm EX YMSAF2 Front Layout Reverse Slide Spec Unit mm 233 850 50 210 569 1348 218 747 324 988 493 6 Shampooing position...

Page 34: ...er flows Refer to page 14 to 15 It may cause malfunction of the product or stain may become hard to remove Immediately wipe away the moisture adheres on the parts except inside of the basin There is a...

Page 35: ...nearest dealer or Takara Belmont directly If water is leaking from the drain hose the drain hose may be worn degraded or damaged Immediately stop using the product and contact the nearest dealer or Ta...

Page 36: ...1E04ZTB0 36 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan TEL 81 6 6213 5945 FAX 81 6 6212 3680 TAKARA BELMONT CORPORATION Printed in Japan...

Reviews: