34
To ensure that this product can be used for a long period of time, conduct the inspections below.
When repair is necessary, contact the nearest dealer or Takara Belmont directly.
■
Inspect the product every day
Inspectionitem
Inspection method
If the inspection results show defects
□
Is the basin unit not
wet with water?
□
Is the mounting
surface of the basin
unit not wet with
water?
□
Have the neck cushion
and head pillows not
degraded?
□
Is there no abnormal
odor coming from the
drain outlet?
□
Does the tap work
properly?
□
Is there no peeling
found on the tap or
thermostatic control
knob?
□
Is water output from
the shower head
properly?
□
Does the
themostatic control
knob work properly?
□
Check if the parts except inside
of the basin is not wet.
□
Visually check the mounting
surface of the basin unit and check
it is not wet with water.
□
Check that there is no tearing, dirt
or sinking on the surface of the
neck cushion and head pillows.
□
Check if there is no abnormal
odor coming from the drain
outlet.
□
Turn the tap and check if warm
water is discharged properly and
there is no abnormal sounds.
Then close the tap and check that
warm water stops properly.
*An abnormal gushing sound may
be emitted as water flows. (Refer
to page 14 to 15.)
□
Visually check that if there is no
scratches, cracks or peeling on the
plated surface of the tap or
thermostatic control knob.
□
Check if there is no abnormal
conditions found when performing
operation or maintenance.
□
Turn on the tap, and visually check
that water is discharged normally
from the shower head, water is not
leaking from the foaming water
outlet, or the hot water is not
turbid.
□
Turn the thermostatic control
knob, check that the water
temperature is adjusted properly
and that there is no abnormal
sound.
*An abnormal gushing sound may
be emitted as water flows. (Refer
to page 14 to 15.)
□
It may cause malfunction of the product, or stain
may become hard to remove.
Immediately wipe away the moisture adheres on
the parts except inside of the basin.
□
There is a possibility that water is leaking inside
of the basin unit. Open the maintenance cover
and check inside (Refer to pages 26 to 28.). If
water is leaking from the pipes, immediately stop
using the product, contact the nearest dealer or
Takara Belmont directly.
□
These may cause pain or transfer dirt to the
client’s neck and head. The neck cushion and
head pillows are consumable supplies. Replace
them as soon as possible.
□
Remove any hair and other objects trapped
in the hair catcher. (Refer to page 23.)
□
If abnormal sounds are heard, or the warm water
does not turn off properly even when the tap is
closed firmly, there may be a malfunction in the
stop valves of the tap.
Contact the nearest dealer or Takara Belmont
directly.
□
It may hurt your hands or fingers with the
scratches, cracks or peeling on the surface of the
plating, so immediately replace it. To replace the
parts, contact the nearest dealer or Takara
Belmont directly.
□
If water is leaking from the foaming water outlet
or from the base of the shower head, the internal
gasket may be worn out.
If replacement is required, contact the nearest
dealer or Takara Belmont directly.
□
If hot water does not come out normally, or it is
turbid, there is a possibility that the filter of the
check valve is contaminated.
Clean the filter. (Refer to pages 26 to 28.)
□
When a few water line splashes out of the water
flows, there is a possibility that lime scale or dirt
may be contaminated in the shower head plate.
Remove the shower head plate and clean it.
(Refer to page 24.)
□
If the water temperature cannot be adjusted
properly or if there is abnormal sounds, there
may be a problem with the thermostat inside of
the basin unit. S top using the product
immediately, and contact the nearest dealer or
Takara Belmont directly.
Procedures for Daily Inspections