- 9 - 

5. Usage of Generator                                     

 

    To keep the generator in optimal con-                           
Dition mechanically and electrically the   
Following points shall be observed. 
      Warning: The generator has to be   
Ground for fear that any mistake would 
Be made electrically. 
 

 

 
        The total power of electric load shall 
not exceed the rated power of the generator. 
        Electric appliances: motor driven de- 
Vices esp.produce large current on starting.   
The following table is for reference to be ma- 
De when the devices. 
        Lised below are connected to the generator. 

 

Summary of Contents for TI9000LXU

Page 1: ... 1 ...

Page 2: ...s 2 3 Check ups before Operation 3 4 Starting of generator 6 5 Usage of Generator 9 6 Stopping of generator 12 7 Maintenance 13 8 Storage 16 9 Troubleshooting 17 10 Technical data 19 11 Battery Unit 20 12 Wheel Unit 23 13 Automatically Gasoline Generator Manual 27 ...

Page 3: ...t indoors 2 Do not open it in wet 3 Do not connect it to the line for house Environment appliance 4 keep flammables 1m 5 Do not overfill to cause over Min away from it flowing while fueling 6 Do not smoke while fueling 7 Stop the engine on fueling ...

Page 4: ... Starting handle 2 Fuel tank up 10 Fuel filter cup 3 AC socket 11 Fuel valve 4 AC breaker 12 Air filter 5 Voltmeter 13 Choke handle 6 Machine oil plug gap 14 Exhaust silencer 7 Engine switch 15 Spark plug 8 Discharging bolt 16 Grounding terminal ...

Page 5: ...Caution Remember that check ups must be carried Out on an even ground with the engine stopped A Insert the oil plug gage into the machine oil filling H H H Hole without turning and check the oil level ole without turning and check the oil level ole without turning and check the oil level ole without turning and check the oil level B When the oil level is too lower refill the machine with machine O...

Page 6: ...the fuel level is too low serew off the fuel tank cap fill it with Fuel to the shoulder of the filter Waring Do not overfill to avoid fuel overflowing C Remount the cap 3 Air filter A Remove the filter cover B Check the filter elemebt to make sure it is clean and intact ...

Page 7: ...eeze dry Drop some drips of machine oil into it Squeeze it dry again D Remount the filter element and put it on filter cover 4 Battery Check to make sure that the electrolyte levelin every call is Between the upper and lower limit lines 1 Upper limit line 2 Lower limit line ...

Page 8: ...ick starter 1 Remove all loads from the AC output terminal 2 Turn off the AC circuit breaker 3 Open the fuel valve 4 Turn the choke handle to CLOSE positioon Caution DO not close the choke when starting a hot engine 5 Turn on the engine switch ...

Page 9: ...then Pull it abruptly Waring Never let the starting pull handle retract suddenly but return it gently 7 When the engine is warmed up set the choke handle to Open position Electric start 1 Remove all loads from the output terminal 2 Turn of the AC breaker 3 Open the fuel valve ...

Page 10: ... handle to Close position Caution Do not close the choke when starting a hot engine 5 Turn on the electronic start switch 6 Release the electric start 7 When the engine is warmed up set the cloke handle to Open position ...

Page 11: ...generator has to be Ground for fear that any mistake would Be made electrically The total power of electric load shall not exceed the rated power of the generator Electric appliances motor driven de Vices esp produce large current on starting The following table is for reference to be ma De when the devices Lised below are connected to the generator ...

Page 12: ...d generator and load should conform to national Standard 4A mm2 When two or more loads are to be connected to the generator they shall be connected from the one requiring larger current to that requiring a small one Note If the generator is to be wired for house power supply wiring Shall be carried out by an electrician Check to make sure that the wiring is correct A wrong wiring will cause damage...

Page 13: ...ing that the voltmete indictes voltage 3 Connecting devices 4 Connecting the AC breaker Note Over current will automatically turn off the AC breaker When that is turned off the generator shall be restarted with load reduced a few minutes thereafter ...

Page 14: ...opping of generator 1 Turn off the AC breaker 2 Turn off the engine switch 3 Remove all loads 4 Close the fuel valve Note When an emergent stop of the engine is needed turn the generator switch to OFF position ...

Page 15: ... 13 7 Mainte nance ...

Page 16: ...ischarging bolt tightly 4 Fill the machine with fresh oil and check the oil level Its machine oil capacity is 1 1L 5 Remount the oil plug gage 2 Spark plug 1 Remove the spark plug cap 2 Remove the spark plug 3 Remove carbon deposit 4 Check the spark plug gap Model of standard spark plug BP5ES BPR5ES NGK W16ERP U W16ERP U DENSO F7RTC ...

Page 17: ... 15 5 Remount the spark plug and its cap 3 Fuel filtering cup 1 Close the fuel valve 2 Remove the setting cup and straining screen 3 Clean the cup and screen 4 Remount the cup and screen ...

Page 18: ...rom The carburetor 4 Screw off the machine oil plug gage discharging bolt and then drain off oil 5 Remount the dis Charging bolt tightly fill The machine with fresh Machine oil to the upper Limit mark and then re Mount the gage 6 Gently pull the start pull handle till some resistance is felt 7 Place the generator in a Clean area ...

Page 19: ... 17 9 Troubleshooting The engine can not start ...

Page 20: ... 18 There is no Voltage Check the circuit protector Check the spark plug ...

Page 21: ... 190FD Bore stroke mm 90 66 Compression ratio 8 0 1 Starting system Electric Recoil Ignition system Induction ignition Fuel tank capacity L 50 Oil capacity L 1 1 enignE Engine type OHV25 Tilt single cylinder forced air cooling 4 stoke N W kg 110 Package dimension mm 740 600 670 noisnemiD Standard features Automatic voltage regulator engine oil warming system large muffler fuel oil indication meter...

Page 22: ... the rear end of the generator 4 Connect the electric start cable to the positive pole first and then to the negative one To disconnect them first remove the negative and then the positive pole 1 Starting solenoid switch 2 Electric start cable 3 Battery protective barrier 4 Battery holder 5 Battery protective plate 6 Battery hold down device 7 Battery to be of 12 35 Amp hr min 8 Cable Notes Be sub...

Page 23: ...e damaged Do not use the Battery upside down 2 Open the oil switch and put it at the start position Start the engine for 2 to 3 times intervally Successful starting means enough electric charge in the battery Failure means charge in the battery is not enough The reason for insufficient charge is that the battery discharge itself during the transportation and storage period Now you need to test the...

Page 24: ...hree how to maintain the battery 1 No overdischarge for the battery when using Charge the battery immediately after discharging 2 Fully charge the battery first remove the negative pole of the battery or the whole battery from the generator when the generator need to stand idle for a long time Check the charge in the battery periodically Charge the battery at once if the electric charge is not eno...

Page 25: ... the axle by washers and pins 2 Fix the wheel axle to the generator by bolts and nuts 1 Internal side 2 Shorter side 3 Longer side 4 Wheel lock pin 5 Lock dise 6 Engine side 7 Washer 8 Pin 9 Wheel 10 Axle on engine side 11 Axle on generator side 12 Bolt 13 Nut ...

Page 26: ...RTS LIST The following items are included with the generator Key No Description Qty 1 Wheel 2 2 Wheel Axle 2 3 Large Cotter Pin 2 4 Small Cotter Pin 4 5 Clevis Pin 2 6 Handle 2 7 Bolt 6 8 Frame Support with Foot 2 ...

Page 27: ...alled on the side opposite the recoil starten NOTE Install the wheels before installing the handle Do not put fuel or oil in the generator before installing the wheels Locate the following items 2 wheel axles 2 wheels 2 small cotter pins 2 large cotter pins Raise the end of the generator opposite the recoil starter high enough to gain access to the frame bottom securely position props underneath t...

Page 28: ... two remaining screws Repeat on other side to install second frame support INSTALLIG THE HANDLES See Figure 3 Locate the following item 2 handles 2 clevis pins 2 small cotter pins With the generator in normal operating position find the holes on the frame above the recoil starter Align the holes in one of the handle brackets with the holes in one side of the generator frame Insert a clevis pin thr...

Page 29: ...y started and stooped when power cut and come It could also automatically adjust the choke to fit the different temperature environment to let the generator reliably start during the range of the pointed temperature Ⅱ Ⅱ Ⅱ Ⅱ Sketch Map 1 Key Switch 2 Pilot Lamp 3 Control Switch 4 Time lapse Switch 5 Volt Meter 6 Circuit breaker 7 Socket 8 Landed wire 9 intake wire N 10 intake wire L ...

Page 30: ...ter into the automatically controlled condition The outlet power is available B Automatically controlled condition If the power network is power off the work indicating light would be off the choke would be automatically controlled and output according to surrounding temperature If the power network is power on the work indicating light would be on generator enter into the automatically controlled...

Page 31: ... not disassemble the control system We arnot be responsible for such caused matters IV The indication of working condition 1 Stand by indicating light ON 2 Generator power outlet indicating light OFF 3 Alarming indicating light blinking V Technical specification 1 8 seconds interval is needed for startup after the power network shut off 2 Ignition control time is 2 5 second 3 Automatically startup...